Systematic Evaluation of Phantom Fluids for Simultaneous PET/MR Hybrid Imaging

Open access

Abstract

UNLABELLED: With the recent advent of integrated PET/MR hybrid systems, the need for simultaneous PET and MR phantom measurements arises. Phantom fluids that are used in stand-alone MR systems, especially in larger phantoms and at a high magnetic field strength, are not necessarily applicable in PET imaging and vice versa. In this study, different approaches to fluid selection were considered and systematically evaluated with respect to their usability for simultaneous PET/MR phantom imaging. METHODS: Demineralized water, water with increased electrical conductivity, a water-oil emulsion, and monoethylene and triethylene glycol were investigated in MR and PET measurements using the most common PET tracer (18)F-FDG. As an alternative to (18)F-FDG, a modified PET tracer ((18)F-fluoride Kryptofix 222 complex) was investigated toward its ability to dissolve in pure oil, which provides good signal homogeneity in MR imaging. Measurements were performed on a 3.0 T integrated PET/MR whole-body system using a National Electrical Manufacturers Association quality-standard phantom. RESULTS: All tested fluids dissolved the radiotracer (18)F-FDG homogeneously. Regarding their suitability for MR at 3.0 T, all fluids significantly improved the homogeneity compared to pure water (increase of excitation flip angle within the tested phantom by a factor of 2.0). When the use of (18)F-FDG was preferred, triethylene glycol provided the best compromise (flip angle increase by a factor of 1.13). The potential alternative tracer, (18)F-fluoride Kryptofix 222 complex, dissolved in pure oil; however, it is not optimal in its tested composition because it accumulates at the bottom of the phantom during the time of measurement. CONCLUSION: This study provides a systematic approach toward phantom fluid selection for imaging a given quality-standard body phantom--and phantoms of comparable size--at 3.0 T. For simultaneous PET/MR scans using the standard tracer (18)F-FDG, an alternative fluid to water and oil is proposed that serves as a viable option for both imaging modalities. Nevertheless, when water is preferred, ways to improve MR image homogeneity are presented. The tested alternative PET tracer enables the use of pure oil in combined scans, but the tracer composition needs to be optimized for phantom measurement applications.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.2967/jnumed.112.116376

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Cross-calibration of PET/MRI scanners is generally hampered by water-filled phantoms, which can produce substantial artifacts in the MR-AC sequence with corresponding SUV errors.

    “It should also be noted that cross-calibration of PET/MRI scanners is generally hampered by water-filled phantoms, which are commonly used for SUV calibration in PET/CT and can produce substantial artifacts in the MR-AC sequence with corresponding SUV errors [63,64].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [63]

    The MR Imaging section (page unavailable) reports that pure water produces artifacts in attenuation-correction images and assigned attenuation values. The Discussion (page unavailable) identifies homogeneous phantom imaging as a prerequisite for MR-based attenuation correction, but does not report corresponding SUV errors or establish that PET/MRI cross-calibration is generally hampered. (LLM, conf=0.84)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

2 of the 25 references couldn’t be matched to a known paper.

Research works printed but not linked: 2

  1. Brown WH, Foote CS, Iverson BL, Anslyn EV. Organic Chemistry. Belmont, CA: Brooks/Cole; 2012:458-459.
  2. Martinez-Möller A, Souvatzoglou M, Delso G, et al. Tissue classification as a potential approach for attenuation correction in whole-body PET/MR imaging. J Nucl Med. 2009;50:520-526.

Cited by

Sorted by citations

Authors
Ziegler, S., Braun, H., Ritt, P., Hocke, C., Kuwert, T., & Quick, H. H.
Affiliations
  • Friedrich-Alexander-Universität Erlangen-Nürnberg (DE)
  • Universitätsklinikum Erlangen (DE)
Venue
Journal of Nuclear Medicine
Published
2013-06-21
Volume
54
Issue
8
Pages
1464-1471
ISSN
  • 0161-5505 (ISSN-L)
  • 2159-662X
OpenAlex
W2163030916
Cited by
50
References
25
Citations by year
2025: 2 · 2024: 2 · 2023: 2 · 2022: 3 · 2021: 7 · 2020: 1 · 2019: 2 · 2018: 3 · 2017: 4 · 2016: 8 · 2015: 8 · 2014: 2 · 2013: 5 · 2012: 1
FWCI
5.92
Type
journal article
Language
en
Open access
Locations
  • Journal of Nuclear Medicine (publishedVersion)
  • PubMed (publishedVersion)
  • Universitätsbibliographie, Universität Duisburg-Essen (submittedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
Keywords
PET/MR imaging, phantom fluid, 18F-FDG, triethylene glycol, water-oil emulsions
MeSH terms
Feasibility Studies, Fluorides, Image Processing, Computer-Assisted, Magnetic Resonance Imaging, Time Factors, Phantoms, Imaging, Fluorodeoxyglucose F18, Positron-Emission Tomography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review