Impact of Image Reconstruction Settings on Texture Features in 18F-FDG PET
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Evaluation of tumor heterogeneity based on texture parameters has recently attracted much interest in the PET imaging community. However, the impact of reconstruction settings on texture parameters is unclear, especially relating to time-of-flight and point-spread function modeling. Their effects on 55 texture features (TFs) and 6 features based on first-order statistics (FOS) were investigated. Standardized uptake value (SUV) measures were also evaluated as peak SUV (SUVpeak), maximum SUV, and mean SUV (SUVmean). METHODS: This study retrospectively recruited 20 patients with lesions in the lung who underwent whole-body (18)F-FDG PET/CT. The coefficient of variation (COV) of each feature across different reconstructions was calculated. RESULTS: SUVpeak, SUVmean, 18 TFs, and 1 FOS were the most robust (COV ≤ 5%) whereas skewness, cluster shade, and zone percentage were the least robust (COV > 20%) with respect to reconstruction algorithms using default settings. Heterogeneity parameters had different sensitivities to iteration number. Twenty-four parameters including SUVpeak and SUVmean exhibited variation with a COV less than 5%; 28 parameters, including maximum SUV, showed variation with a COV in the range of 5%-10%. In addition, skewness, cluster shade, and zone percentage were the most sensitive to iteration number. In terms of sensitivity to full width at half maximum (FWHM), 15 TFs and 1 FOS had the best performance with a COV less than 5%, whereas SUVpeak and SUVmean had a COV between 5% and 10%. Grid size had the largest impact on image features, which was demonstrated by only 11 features, including SUVpeak and SUVmean, having a COV less than 10%. CONCLUSION: Different image features have different sensitivities to reconstruction settings. Iteration number and FWHM of the gaussian filter have a similar impact on the image features. Grid size has a larger impact on the features than iteration number and FWHM. The features that exhibited large variations such as skewness in FOS, cluster shade, and zone percentage should be used with caution. The entropy in FOS, difference entropy, inverse difference normalized, inverse difference moment normalized, low gray-level run emphasis, high gray-level run emphasis, and low gray-level zone emphasis are the most robust features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886 · cited 9×
“A second-order feature is usually calculated from the gray level cooccurrence matrix (GLCM) (28).”
BackgroundInfluentialIntratumor Heterogeneity and Branched Evolution Revealed by Multiregion Sequencing
Gerlinger, M., Rowan, A. J., Horswell, S., Larkin, J., Endesfelder, D., Gronroos, E., Martinez, P., Matthews, N., Stewart, A., Tarpey, P., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1113205 · Cited by 7,774 · cited 1×
“Recent studies have shown that tumors often display startling intratumoral heterogeneity, which is often associated with adverse tumor biology (1,2).”
BackgroundHypoxia and hypoxia-inducible factors: master regulators of metastasis
Lu, X., & Kang, Y. (2010) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-10-1360 · Cited by 723 · cited 1×
“A tumor VOI was delineated using a fixed threshold set to 40% of the SUVmax in the lesion and followed by a morphologic closing operation to include necrotic regions since tumor heterogeneity is often associated with hypoxia and subsequent necrosis (27).”
MethodImpact of Time-of-Flight on PET Tumor Detection
Kadrmas, D. J., Casey, M. E., Conti, M., Jakoby, B. W., Lois, C., & Townsend, D. W. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.063016 · Cited by 277 · cited 4×
“Consistent with the previous findings (22-26), OSEM+TOF+PSF produced visually the best image among the chosen 4 reconstruction algorithms with their default settings.”
BackgroundMethodResultInfluentialSelf-citationAkamatsu, G., Ishikawa, K., Mitsumoto, K., Taniguchi, T., Ohya, N., Baba, S., Abe, K., & Sasaki, M. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.103861 · Cited by 206
Variations in Clinical PET/CT Operations: Results of an International Survey of Active PET/CT Users
Beyer, T., Czernin, J., & Freudenberg, L. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.079624 · Cited by 136 · cited 1×
“In oncology, 18F-FDG PET is currently playing a major role in clinical diagnosis, staging, prognosis, and assessment of response to treatment (3).”
BackgroundSurti, S., Scheuermann, J., El Fakhri, G., Daube-Witherspoon, M. E., Lim, R., Abi-Hatem, N., Moussallem, E., Benard, F., Mankoff, D., & Karp, J. S. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.086678 · Cited by 104 · cited 3×
“Consistent with the previous findings (22-26), OSEM+TOF+PSF produced visually the best image among the chosen 4 reconstruction algorithms with their default settings.”
BackgroundResultSchaefferkoetter, J., Casey, M., Townsend, D., & El Fakhri, G. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/5/1465 · Cited by 85 · cited 4×
“Consistent with the previous findings (22-26), OSEM+TOF+PSF produced visually the best image among the chosen 4 reconstruction algorithms with their default settings.”
BackgroundMethodResultInfluentialSelf-citation
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
Mayerhoefer, M. E., Materka, A., Langs, G., Häggström, I., Szczypiński, P., Gibbs, P., & Cook, G. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.222893 · Cited by 1,777
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Applications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Nioche, C., Orlhac, F., Boughdad, S., Reuzé, S., Goya-Outi, J., Robert, C., Pellot-Barakat, C., Soussan, M., Frouin, F., & Buvat, I. (2018) · Cancer Research · doi:10.1158/0008-5472.can-18-0125 · Cited by 1,167
Liu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
AI applications to medical images: From machine learning to deep learning
Castiglioni, I., Rundo, L., Codari, M., Di Leo, G., Salvatore, C., Interlenghi, M., Gallivanone, F., Cozzi, A., D'Amico, N. C., & Sardanelli, F. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.02.006 · Cited by 710
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Validation of A Method to Compensate Multicenter Effects Affecting CT Radiomics
Orlhac, F., Frouin, F., Nioche, C., Ayache, N., & Buvat, I. (2019) · Radiology · doi:10.1148/radiol.2019182023 · Cited by 411
A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET
Orlhac, F., Boughdad, S., Philippe, C., Stalla-Bourdillon, H., Nioche, C., Champion, L., Soussan, M., Frouin, F., Frouin, V., & Buvat, I. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.199935 · Cited by 393
Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
A Guide to ComBat Harmonization of Imaging Biomarkers in Multicenter Studies
Orlhac, F., Eertink, J. J., Cottereau, A.-S., Zijlstra, J. M., Thieblemont, C., Meignan, M., Boellaard, R., & Buvat, I. (2022) · Journal of Nuclear Medicine · doi:10.2967/jnumed.121.262464 · Cited by 348
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Papadimitroulas, P., Brocki, L., Christopher Chung, N., Marchadour, W., Vermet, F., Gaubert, L., Eleftheriadis, V., Plachouris, D., Visvikis, D., Kagadis, G. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.009 · Cited by 226
“Indeed, most radiomic features have been shown to be highly sensitive to variations in several factors, including variability in scanner manufacturer, generation and models, acquisition protocols and reconstruction settings [130 – 132].”
BackgroundHow can we combat multicenter variability in MR radiomics? Validation of a correction procedure
Orlhac, F., Lecler, A., Savatovski, J., Goya-Outi, J., Nioche, C., Charbonneau, F., Ayache, N., Frouin, F., Duron, L., & Buvat, I. (2021) · European Radiology · doi:10.1007/s00330-020-07284-9 · Cited by 210
Mali, S. A., Ibrahim, A., Woodruff, H. C., Andrearczyk, V., Müller, H., Primakov, S., Salahuddin, Z., Chatterjee, A., & Lambin, P. (2021) · Journal of Personalized Medicine · doi:10.3390/jpm11090842 · Cited by 207
Shiri, I., Rahmim, A., Ghaffarian, P., Geramifar, P., Abdollahi, H., & Bitarafan-Rajabi, A. (2017) · European Radiology · doi:10.1007/s00330-017-4859-z · Cited by 204
Da-ano, R., Masson, I., Lucia, F., Doré, M., Robin, P., Alfieri, J., Rousseau, C., Mervoyer, A., Reinhold, C., Castelli, J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-66110-w · Cited by 204
Test–Retest Data for Radiomics Feature Stability Analysis: Generalizable or Study-Specific?
van Timmeren, J. E., Leijenaar, R. T. H., van Elmpt, W., Wang, J., Zhang, Z., Dekker, A., & Lambin, P. (2016) · Tomography · doi:10.18383/j.tom.2016.00208 · Cited by 191
“Several studies assessed the influence of different scanners and reconstruction settings (10-15).”
BackgroundKirienko, M., Cozzi, L., Antunovic, L., Lozza, L., Fogliata, A., Voulaz, E., Rossi, A., Chiti, A., & Sollini, M. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3837-7 · Cited by 179
Lucia, F., Visvikis, D., Vallières, M., Desseroit, M.-C., Miranda, O., Robin, P., Bonaffini, P. A., Alfieri, J., Masson, I., Mervoyer, A., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4231-9 · Cited by 178
“EntropyGLCM has been shown to be quite robust to variations in most image properties [21], whereas GLNUGLRLM has been described as more sensitive, especially to voxel size [22].”
BackgroundChallenges and Promises of PET Radiomics
Cook, G. J. R., Azad, G., Owczarczyk, K., Siddique, M., & Goh, V. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.12.268 · Cited by 167
“Few parameters are robust to all the technical factors described, in particular, quantization and reconstruction algorithm, with lesser or variable, but measurable, effects from segmentation and smoothing (34, 38-40, 43, 47, 48).”
BackgroundTexture analysis of medical images for radiotherapy applications
Scalco, E., & Rizzo, G. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160642 · Cited by 165
FDG PET/CT radiomics for predicting the outcome of locally advanced rectal cancer
Lovinfosse, P., Polus, M., Van Daele, D., Martinive, P., Daenen, F., Hatt, M., Visvikis, D., Koopmansch, B., Lambert, F., Coimbra, C., et al. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3855-5 · Cited by 165
“However, coarseness is affected by the reconstruction settings which need to be standardized in multicenter trials [45].”
BackgroundHarmonization strategies for multicenter radiomics investigations
Da-Ano, R., Visvikis, D., & Hatt, M. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aba798 · Cited by 161
“Since most radiomic features have been shown to be sensitive to variations in these factors (Galavis et al 2010, Yan et al 2015, Jochems et al 2016, Zwanenburg 2019, © 2020 Institute of Physics and Engineering inMedicine Zwanenburg and Löck), pooling them to do any statistical analysis and build…”
BackgroundDesseroit, M.-C., Tixier, F., Weber, W. A., Siegel, B. A., Cheze Le Rest, C., Visvikis, D., & Hatt, M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180919 · Cited by 160
PET Radiomics in NSCLC: state of the art and a proposal for harmonization of methodology
Sollini, M., Cozzi, L., Antunovic, L., Chiti, A., & Kirienko, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-00426-y · Cited by 158
Shayesteh, S., Nazari, M., Salahshour, A., Sandoughdaran, S., Hajianfar, G., Khateri, M., Yaghobi Joybari, A., Jozian, F., Fatehi Feyzabad, S. H., Arabi, H., et al. (2021) · Medical Physics · doi:10.1002/mp.14896 · Cited by 70
Reynés‐Llompart, G., Gámez‐Cenzano, C., Vercher‐Conejero, J. L., Sabaté‐Llobera, A., Calvo‐Malvar, N., & Martí‐Climent, J. M. (2018) · Medical Physics · doi:10.1002/mp.12986 · Cited by 55
“despite this for the proposed clinical range of b values, we could consider that the COVobtained are compatible with the results of previous publications on the impact of reconstruction settings for OSEM-like algorithms.(22,31) The interpretation of the differences in our results and previous works is not straightforw…”
ResultLee, J. W., Park, S.-H., Ahn, H., Lee, S. M., & Jang, S. J. (2021) · Cancers · doi:10.3390/cancers13143563 · Cited by 18
Metadata
- Authors
- Yan, J., Chu-Shern, J. L., Loi, H. Y., Khor, L. K., Sinha, A. K., Quek, S. T., Tham, I. W. K., & Townsend, D.
- Venue
- Journal of Nuclear Medicine
- Publisher
- Society of Nuclear Medicine
- Published
- 2015-07-30
- Volume
- 56
- Issue
- 11
- Pages
- 1667-1673
- ISSN
- 0161-5505 (ISSN-L)
- 2159-662X
- OpenAlex
- W2173608465
- Cited by
- 242
- References
- 8
- FWCI
- 19.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.