Is CEM43 still a relevant thermal dose parameter for hyperthermia treatment monitoring?
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
CEM43 has its roots in the direct cytotoxic effect of heat, whereby the amount of cell death depends on the temperature and exposure time. CEM43 is a normalising method to convert the various time-temperature exposures applied into an equivalent exposure time expressed as minutes at the reference temperature of 43 °C. The CEM43 concept also holds a number of weaknesses, however. When used to predict treatment efficacy of combined radiotherapy plus hyperthermia, CEM43 does not include the effect of sensitisation by enhanced oxygenation, variation in interval time and the effect of multiple fractions. Further, it does not include the effect of increased perfusion at the lower thermal dose - and the occurrence of stasis at the higher thermal dose. Overall, studies towards a thermal dose-effect relationship in radiotherapy plus hyperthermia present a diffuse message without a definitive conclusion. However, prospective studies and studies with large patient numbers did report significant thermal dose-effect relationships and provide a good reason to continue research in the CEM43 model. Such research would be best performed in homogeneous patient groups with a single pathology and a low variation in tumour size and heterogeneity. Further, high quality thermometry, strict treatment schedules with fixed intervals and preferably homogenous heating are important requirements to enhance the probability of detecting a thermal dose-effect relationship. The slowly growing availability of hybrid MR hyperthermia systems should be a strong stimulus to expand these studies with the inclusion of measuring thermal dose-dependent blood flow and oxygen changes in the tumour and normal tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Basic principles of thermal dosimetry and thermal thresholds for tissue damage from hyperthermia
Dewhirst, M. W., Viglianti, B. L., Lora-Michiels, M., Hanson, M., & Hoopes, P. J. (2003) · International Journal of Hyperthermia · doi:10.1080/0265673031000119006 · Cited by 1,014
Cellular Responses to Combinations of Hyperthermia and Radiation
Dewey, W. C., Hopwood, L. E., Sapareto, S. A., & Gerweck, L. E. (1977) · Radiology · doi:10.1148/123.2.463 · Cited by 929
Effect of local hyperthermia on blood flow and microenvironment: a review.
Song, C. W. (1984) · PubMed · Cited by 770
Thresholds for thermal damage to normal tissues: An update
Yarmolenko, P. S., Moon, E. J., Landon, C., Manzoor, A., Hochman, D. W., Viglianti, B. L., & Dewhirst, M. W. (2011) · International Journal of Hyperthermia · doi:10.3109/02656736.2010.534527 · Cited by 754
Issels, R. D., Lindner, L. H., Verweij, J., Wust, P., Reichardt, P., Schem, B.-C., Abdel-Rahman, S., Daugaard, S., Salat, C., Wendtner, C.-M., et al. (2010) · The Lancet Oncology · doi:10.1016/s1470-2045(10)70071-1 · Cited by 659
Datta, N. R., Ordóñez, S. G., Gaipl, U. S., Paulides, M. M., Crezee, H., Gellermann, J., Marder, D., Puric, E., & Bodis, S. (2015) · Cancer Treatment Reviews · doi:10.1016/j.ctrv.2015.05.009 · Cited by 588
Cellular responses to hyperthermia (40–46°C): Cell killing and molecular events
Roti Roti, J. L. (2008) · International Journal of Hyperthermia · doi:10.1080/02656730701769841 · Cited by 573
Randomized Trial of Hyperthermia and Radiation for Superficial Tumors
Jones, E. L., Oleson, J. R., Prosnitz, L. R., Samulski, T. V., Vujaskovic, Z., Yu, D., Sanders, L. L., & Dewhirst, M. W. (2005) · Journal of Clinical Oncology · doi:10.1200/jco.2005.05.520 · Cited by 560
Arrhenius relationships from the molecule and cell to the clinic
Dewey, W. C. (1994) · International Journal of Hyperthermia · doi:10.3109/02656739409009351 · Cited by 501
Hyperthermia: a Potent Enhancer of Radiotherapy
Horsman, M. R., & Overgaard, J. (2007) · Clinical Oncology · doi:10.1016/j.clon.2007.03.015 · Cited by 463
Cited by
Tay, Z. W., Chandrasekharan, P., Chiu-Lam, A., Hensley, D. W., Dhavalikar, R., Zhou, X. Y., Yu, E. Y., Goodwill, P. W., Zheng, B., Rinaldi, C., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b00893 · Cited by 459
Heating technology for malignant tumors: a review
Kok, H. P., Cressman, E. N. K., Ceelen, W., Brace, C. L., Ivkov, R., Grüll, H., ter Haar, G., Wust, P., & Crezee, J. (2020) · International Journal of Hyperthermia · doi:10.1080/02656736.2020.1779357 · Cited by 422
Hyperthermia can alter tumor physiology and improve chemo- and radio-therapy efficacy
Dunne, M., Regenold, M., & Allen, C. (2020) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2020.07.007 · Cited by 150
SAR thresholds for electromagnetic exposure using functional thermal dose limits
Adibzadeh, F., Paulides, M. M., & van Rhoon, G. C. (2018) · International Journal of Hyperthermia · doi:10.1080/02656736.2018.1424945 · Cited by 23
Metadata
- Authors
- van Rhoon, G. C.
- Venue
- International Journal of Hyperthermia
- Publisher
- Informa UK Limited
- Published
- 2016-01-02
- Volume
- 32
- Issue
- 1
- Pages
- 50-62
- ISSN
- 0265-6736 (ISSN-L)
- 1464-5157
- OpenAlex
- W2289223631
- Cited by
- 176
- References
- 62
- FWCI
- 6.54
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Is CEM43 still a relevant thermal dose parameter for hyperthermia treatment monitoring? https://app.cochat.ai/papers/10.3109/02656736.2015.1114153
- The paper
- van Rhoon, G. C. (2016). Is CEM43 still a relevant thermal dose parameter for hyperthermia treatment monitoring? International Journal of Hyperthermia. https://doi.org/10.3109/02656736.2015.1114153
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.