CoChat

Non-uniform swelling properties of the corneal stroma

Lee, David, Wilson, Graeme · 1981 · Current Eye Research
Cited by 72

The DOI matches its Crossref record.

Abstract

The swelling properties of the anterior and posterior stroma of bovine and rabbit corneas were examined by three different methods. The results show that the posterior stroma can swell more than the anterior stroma. Also, at a given swelling pressure, the posterior stroma is more hydrated than the anterior stroma. In a third experiment it is demonstrated that the posterior stroma is also more hydrated in the living eye. It is concluded that the stroma is not a homogeneous structure. The superficial stroma has different physiological properties from the deep stroma. These differences must be taken into account in theoretical models of corneal deturgescence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/02713688109019986

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 72

Metadata

Authors
Lee, D., & Wilson, G.
Venue
Current Eye Research
Published
1981-01
Volume
1
Issue
8
Pages
457-461
ISSN
  • 0271-3683 (ISSN-L)
  • 1460-2202
OpenAlex
W2129563426
Cited by
72
References
0
FWCI
0.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Non-uniform swelling properties of the corneal stroma. https://app.cochat.ai/papers/10.3109/02713688109019986
The paper
Lee, D., & Wilson, G. (1981). Non-uniform swelling properties of the corneal stroma. Current Eye Research. https://doi.org/10.3109/02713688109019986

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.