Variability of textural features in FDG PET images due to different acquisition modes and reconstruction parameters
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Characterization of textural features (spatial distributions of image intensity levels) has been considered as a tool for automatic tumor segmentation. The purpose of this work is to study the variability of the textural features in PET images due to different acquisition modes and reconstruction parameters. MATERIAL AND METHODS: Twenty patients with solid tumors underwent PET/CT scans on a GE Discovery VCT scanner, 45-60 minutes post-injection of 10 mCi of [(18)F]FDG. Scans were acquired in both 2D and 3D modes. For each acquisition the raw PET data was reconstructed using five different reconstruction parameters. Lesions were segmented on a default image using the threshold of 40% of maximum SUV. Fifty different texture features were calculated inside the tumors. The range of variations of the features were calculated with respect to the average value. RESULTS: Fifty textural features were classified based on the range of variation in three categories: small, intermediate and large variability. Features with small variability (range ≤ 5%) were entropy-first order, energy, maximal correlation coefficient (second order feature) and low-gray level run emphasis (high-order feature). The features with intermediate variability (10% ≤ range ≤ 25%) were entropy-GLCM, sum entropy, high gray level run emphsis, gray level non-uniformity, small number emphasis, and entropy-NGL. Forty remaining features presented large variations (range > 30%). CONCLUSION: Textural features such as entropy-first order, energy, maximal correlation coefficient, and low-gray level run emphasis exhibited small variations due to different acquisition modes and reconstruction parameters. Features with low level of variations are better candidates for reproducible tumor segmentation. Even though features such as contrast-NGTD, coarseness, homogeneity, and busyness have been previously used, our data indicated that these features presented large variations, therefore they could not be considered as a good candidates for tumor segmentation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Qidwai, U., & Chen, C. H. (2009) · Chapman & Hall/CRC eBooks · doi:10.1201/9781420079517 · Cited by 1,701
Textural features corresponding to textural properties
Amadasun, M., & King, R. (1989) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.44046 · Cited by 1,148
Texture information in run-length matrices
Tang, X. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.725367 · Cited by 654
(2005) · PubMed · Cited by 612
Understanding the standardized uptake value, its methods, and implications for usage.
Thie, J. A. (2004) · PubMed · Cited by 546
Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.011 · Cited by 480
Neighboring gray level dependence matrix for texture classification
Sun, C., & Wee, W. G. (1983) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(83)90032-4 · Cited by 408
Paulino, A. C., Koshy, M., Howell, R., Schuster, D., & Davis, L. W. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.08.037 · Cited by 264
Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusion
Riegel, A. C., Berson, A. M., Destian, S., Ng, T., Tena, L. B., Mitnick, R. J., & Wong, P. S. (2006) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2006.01.014 · Cited by 242
Cited by
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Mayerhoefer, M. E., Materka, A., Langs, G., Häggström, I., Szczypiński, P., Gibbs, P., & Cook, G. (2020) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.222893 · Cited by 1,777
Applications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Liu, Z., Wang, S., Dong, D., Wei, J., Fang, C., Zhou, X., Sun, K., Li, L., Li, B., Wang, M., et al. (2019) · Theranostics · doi:10.7150/thno.30309 · Cited by 967
Repeatability and Reproducibility of Radiomic Features: A Systematic Review
Traverso, A., Wee, L., Dekker, A., & Gillies, R. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.05.053 · Cited by 903
Assessment of tumor heterogeneity: an emerging imaging tool for clinical practice?
Davnall, F., Yip, C. S. P., Ljungqvist, G., Selmi, M., Ng, F., Sanghera, B., Ganeshan, B., Miles, K. A., Cook, G. J., & Goh, V. (2012) · Insights into Imaging · doi:10.1007/s13244-012-0196-6 · Cited by 878
Limkin, E. J., Sun, R., Dercle, L., Zacharaki, E. I., Robert, C., Reuzé, S., Schernberg, A., Paragios, N., Deutsch, E., & Ferté, C. (2017) · Annals of Oncology · doi:10.1093/annonc/mdx034 · Cited by 757
Robust Radiomics Feature Quantification Using Semiautomatic Volumetric Segmentation
Parmar, C., Rios Velazquez, E., Leijenaar, R., Jermoumi, M., Carvalho, S., Mak, R. H., Mitra, S., Shankar, B. U., Kikinis, R., Haibe-Kains, B., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0102107 · Cited by 611
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Intrinsic dependencies of CT radiomic features on voxel size and number of gray levels
Shafiq‐ul‐Hassan, M., Zhang, G. G., Latifi, K., Ullah, G., Hunt, D. C., Balagurunathan, Y., Abdalah, M. A., Schabath, M. B., Goldgof, D. G., Mackin, D., et al. (2017) · Medical Physics · doi:10.1002/mp.12123 · Cited by 585
Reproducibility of radiomics for deciphering tumor phenotype with imaging
Zhao, B., Tan, Y., Tsai, W.-Y., Qi, J., Xie, C., Lu, L., & Schwartz, L. H. (2016) · Scientific Reports · doi:10.1038/srep23428 · Cited by 509
Quantifying tumour heterogeneity in 18F-FDG PET/CT imaging by texture analysis
Chicklore, S., Goh, V., Siddique, M., Roy, A., Marsden, P. K., & Cook, G. J. R. (2013) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-012-2247-0 · Cited by 488
Beyond imaging: The promise of radiomics
Avanzo, M., Stancanello, J., & El Naqa, I. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.071 · Cited by 483
Characterization of PET/CT images using texture analysis: the past, the present… any future?
Hatt, M., Tixier, F., Pierce, L., Kinahan, P. E., Le Rest, C. C., & Visvikis, D. (2017) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-016-3427-0 · Cited by 475
Hatt, M., Majdoub, M., Vallières, M., Tixier, F., Le Rest, C. C., Groheux, D., Hindié, E., Martineau, A., Pradier, O., Hustinx, R., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.144055 · Cited by 438
Leijenaar, R. T. H., Carvalho, S., Velazquez, E. R., van Elmpt, W. J. C., Parmar, C., Hoekstra, O. S., Hoekstra, C. J., Boellaard, R., Dekker, A. L. A. J., Gillies, R. J., et al. (2013) · Acta Oncologica · doi:10.3109/0284186x.2013.812798 · Cited by 427
Leijenaar, R. T. H., Nalbantov, G., Carvalho, S., van Elmpt, W. J. C., Troost, E. G. C., Boellaard, R., Aerts, H. J. W. L., Gillies, R. J., & Lambin, P. (2015) · Scientific Reports · doi:10.1038/srep11075 · Cited by 426
Radiomic Machine-Learning Classifiers for Prognostic Biomarkers of Head and Neck Cancer
Parmar, C., Grossmann, P., Rietveld, D., Rietbergen, M. M., Lambin, P., & Aerts, H. J. W. L. (2015) · Frontiers in Oncology · doi:10.3389/fonc.2015.00272 · Cited by 407
A Postreconstruction Harmonization Method for Multicenter Radiomic Studies in PET
Orlhac, F., Boughdad, S., Philippe, C., Stalla-Bourdillon, H., Nioche, C., Champion, L., Soussan, M., Frouin, F., Frouin, V., & Buvat, I. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.199935 · Cited by 393
Park, J. E., Park, S. Y., Kim, H. J., & Kim, H. S. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0070 · Cited by 388
Exploratory Study to Identify Radiomics Classifiers for Lung Cancer Histology
Wu, W., Parmar, C., Grossmann, P., Quackenbush, J., Lambin, P., Bussink, J., Mak, R., & Aerts, H. J. W. L. (2016) · Frontiers in Oncology · doi:10.3389/fonc.2016.00071 · Cited by 378
Larue, R. T. H. M., Defraene, G., De Ruysscher, D., Lambin, P., & van Elmpt, W. (2017) · The British Journal of Radiology · doi:10.1259/bjr.20160665 · Cited by 363
Orlhac, F., Soussan, M., Maisonobe, J.-A., Garcia, C. A., Vanderlinden, B., & Buvat, I. (2014) · Journal of Nuclear Medicine · doi:10.2967/jnumed.113.129858 · Cited by 356
False Discovery Rates in PET and CT Studies with Texture Features: A Systematic Review
Chalkidou, A., O’Doherty, M. J., & Marsden, P. K. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124165 · Cited by 344
Tixier, F., Hatt, M., Le Rest, C. C., Le Pogam, A., Corcos, L., & Visvikis, D. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.111.099127 · Cited by 318
Zwanenburg, A. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-019-04391-8 · Cited by 306
van Velden, F. H. P., Kramer, G. M., Frings, V., Nissen, I. A., Mulder, E. R., de Langen, A. J., Hoekstra, O. S., Smit, E. F., & Boellaard, R. (2016) · Molecular Imaging and Biology · doi:10.1007/s11307-016-0940-2 · Cited by 286
Lucia, F., Visvikis, D., Desseroit, M.-C., Miranda, O., Malhaire, J.-P., Robin, P., Pradier, O., Hatt, M., & Schick, U. (2018) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-017-3898-7 · Cited by 245
“Other factors such as image acquisition parameters [29], tumor volume [30], gray-level discretization, and other preprocessing steps [8, 28] can influence radiomics findings.”
BackgroundPapadimitroulas, P., Brocki, L., Christopher Chung, N., Marchadour, W., Vermet, F., Gaubert, L., Eleftheriadis, V., Plachouris, D., Visvikis, D., Kagadis, G. C., et al. (2021) · Physica Medica · doi:10.1016/j.ejmp.2021.03.009 · Cited by 226
“…radiomic features because they have been identified to be unreliable (i.e., exhibit unreasonable variations in response to small variability of acquisition and reconstruction settings [130] or in a test – retest framework [148] before even considering them in any statistical analysis [149].”
BackgroundLeijenaar, R. T. H., Carvalho, S., Hoebers, F. J. P., Aerts, H. J. W. L., van Elmpt, W. J. C., Huang, S. H., Chan, B., Waldron, J. N., O’sullivan, B., & Lambin, P. (2015) · Acta Oncologica · doi:10.3109/0284186x.2015.1061214 · Cited by 217
Shiri, I., Rahmim, A., Ghaffarian, P., Geramifar, P., Abdollahi, H., & Bitarafan-Rajabi, A. (2017) · European Radiology · doi:10.1007/s00330-017-4859-z · Cited by 204
Da-ano, R., Masson, I., Lucia, F., Doré, M., Robin, P., Alfieri, J., Rousseau, C., Mervoyer, A., Reinhold, C., Castelli, J., et al. (2020) · Scientific Reports · doi:10.1038/s41598-020-66110-w · Cited by 204
Test–Retest Data for Radiomics Feature Stability Analysis: Generalizable or Study-Specific?
van Timmeren, J. E., Leijenaar, R. T. H., van Elmpt, W., Wang, J., Zhang, Z., Dekker, A., & Lambin, P. (2016) · Tomography · doi:10.18383/j.tom.2016.00208 · Cited by 191
“Several studies assessed the influence of different scanners and reconstruction settings (10-15).”
BackgroundLucia, F., Visvikis, D., Vallières, M., Desseroit, M.-C., Miranda, O., Robin, P., Bonaffini, P. A., Alfieri, J., Masson, I., Mervoyer, A., et al. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4231-9 · Cited by 178
“One of the main challenges in validating radiomics-based models in cohorts from different centers is the need to pool imaging data generated with different imaging and reconstruction protocols, as it has been shown that radiomics features are often very sensitive to the acquisition and reconstruction parameters, among…”
BackgroundChallenges and Promises of PET Radiomics
Cook, G. J. R., Azad, G., Owczarczyk, K., Siddique, M., & Goh, V. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2017.12.268 · Cited by 167
“Few parameters are robust to all the technical factors described, in particular, quantization and reconstruction algorithm, with lesser or variable, but measurable, effects from segmentation and smoothing (34, 38-40, 43, 47, 48).”
BackgroundMethodHarmonization strategies for multicenter radiomics investigations
Da-Ano, R., Visvikis, D., & Hatt, M. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aba798 · Cited by 161
“Since most radiomic features have been shown to be sensitive to variations in these factors (Galavis et al 2010, Yan et al 2015, Jochems et al 2016, Zwanenburg 2019, © 2020 Institute of Physics and Engineering inMedicine Zwanenburg and Löck), pooling them to do any statistical analysis and build…”
BackgroundDesseroit, M.-C., Tixier, F., Weber, W. A., Siegel, B. A., Cheze Le Rest, C., Visvikis, D., & Hatt, M. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.180919 · Cited by 160
Vanderhoek, M., Perlman, S. B., & Jeraj, R. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.113332 · Cited by 47
“It is also quite possible that alternative, non-SUV measures may be better suited for PETbased assessment of treatment response (27,28).”
BackgroundSelf-citationNakajo, M., Jinguji, M., Nakajo, M., Shinaji, T., Nakabeppu, Y., Fukukura, Y., & Yoshiura, T. (2017) · Abdominal Radiology · doi:10.1007/s00261-017-1207-3 · Cited by 32
“Tumor uptake heterogeneity was quantified considering only those parameters that have been previously shown as robust in terms of image reconstruction and acquisition variability [18, 19], and physiological reproducibility based on double-baseline PET acquisitions [20].”
MethodSmeets, E. M. M., Withaar, D. S., Grootjans, W., Hermans, J. J., van Laarhoven, K., de Geus-Oei, L.-F., Gotthardt, M., & Aarntzen, E. H. J. G. (2019) · EJNMMI Research · doi:10.1186/s13550-019-0492-y · Cited by 12
Metadata
- Authors
- Galavis, P. E., Hollensen, C., Jallow, N., Paliwal, B., & Jeraj, R.
- Venue
- Acta Oncologica
- Published
- 2010-09-13
- Volume
- 49
- Issue
- 7
- Pages
- 1012-1016
- ISSN
- 0284-186X (ISSN-L)
- 1651-226X
- OpenAlex
- W2046032792
- Cited by
- 344
- References
- 19
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.