Respiratory rate estimation during triage of children in hospitals
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Accurate assessment of a child's health is critical for appropriate allocation of medical resources and timely delivery of healthcare in Emergency Departments. The accurate measurement of vital signs is a key step in the determination of the severity of illness and respiratory rate is currently the most difficult vital sign to measure accurately. Several previous studies have attempted to extract respiratory rate from photoplethysmogram (PPG) recordings. However, the majority have been conducted in controlled settings using PPG recordings from healthy subjects. In many studies, manual selection of clean sections of PPG recordings was undertaken before assessing the accuracy of the signal processing algorithms developed. Such selection procedures are not appropriate in clinical settings. A major limitation of AR modelling, previously applied to respiratory rate estimation, is an appropriate selection of model order. This study developed a novel algorithm that automatically estimates respiratory rate from a median spectrum constructed applying multiple AR models to processed PPG segments acquired with pulse oximetry using a finger probe. Good-quality sections were identified using a dynamic template-matching technique to assess PPG signal quality. The algorithm was validated on 205 children presenting to the Emergency Department at the John Radcliffe Hospital, Oxford, UK, with reference respiratory rates up to 50 breaths per minute estimated by paediatric nurses. At the time of writing, the authors are not aware of any other study that has validated respiratory rate estimation using data collected from over 200 children in hospitals during routine triage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
EEG analysis based on time domain properties
Hjorth, B. (1970) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(70)90143-4 · Cited by 1,504
Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
Li, Q., & Clifford, G. D. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/9/1491 · Cited by 274 · cited 1×
“Our algorithm for deriving a signal quality index combines beat-by-beat analysis with template matching [55], as illustrated in Figure 7.”
MethodPhotoplethysmographic derivation of respiratory rate: A review of relevant physiology
Meredith, D. J., Clifton, D., Charlton, P., Brooks, J., Pugh, C. W., & Tarassenko, L. (2012) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.638965 · Cited by 226
Self-citationSignal quality measures for pulse oximetry through waveform morphology analysis
Sukor, J. A., Redmond, S. J., & Lovell, N. H. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/3/008 · Cited by 166
Krishnan, R., Natarajan, B., & Warren, S. (2008) · 2008 IEEE International Conference on Acoustics, Speech and Signal Processing · doi:10.1109/icassp.2008.4517684 · Cited by 45
Cited by
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Toward a Robust Estimation of Respiratory Rate From Pulse Oximeters
Pimentel, M. A. F., Johnson, A. E. W., Charlton, P. H., Birrenkott, D., Watkinson, P. J., Tarassenko, L., & Clifton, D. A. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2613124 · Cited by 387
Self-citationBreathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
“This will provide evidence for the expected performance of a BR algorithm in a particular target population (such as children [125], [189], [209]), and it will allow the most suitable BR algorithm for that population to be identified.”
Self-citationCharlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366
Self-citationShah, S. A., Velardo, C., Farmer, A., & Tarassenko, L. (2017) · Journal of Medical Internet Research · doi:10.2196/jmir.7207 · Cited by 172
“This novel signal processing approach was developed by us to estimate respiratory rate from PPG data in a different clinical setting [17].”
MethodSelf-citationBirrenkott, D. A., Pimentel, M. A. F., Watkinson, P. J., & Clifton, D. A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2778265 · Cited by 71
“We chose the ARSpec algorithm [26] due to its reliability and availability.”
Method
Metadata
- Authors
- Shah, S. A., Fleming, S., Thompson, M., & Tarassenko, L.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2015-11-07
- Volume
- 39
- Issue
- 8
- Pages
- 514-524
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2107820561
- Cited by
- 45
- References
- 6
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.