PLGA–PEG–PLGA hydrogel for ocular drug delivery of dexamethasone acetate
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
AIM: This study aims to investigate the suitability of thermosensitive triblock polymer poly-(DL-lactic acid-co-glycolic acid) (PLGA)-polyethylene glycol (PEG)-PLGA as a matrix material for ocular delivery of dexamethasone acetate (DXA). METHODS: The copolymer was synthesized and evaluated for its thermosensitive and gelation properties. DXA in situ gel-forming solution based on PLGA-PEG-PLGA copolymer of 20% (w/w) was prepared and evaluated for ocular pharmacokinetics in rabbit according to the microdialysis method, which was compared to the normal eye drop. RESULT: The copolymer with 20% (w/w) had a low critical solution temperature of 32 degrees C, which is close to the surface temperature of the eye. The C(max) of DXA in the anterior chamber for the PLGA-PEG-PLGA solution was 125.2 microg/mL, which is sevenfold higher than that of the eye drop, along with greater area under the concentration-time curves (AUC). CONCLUSION: These results suggest that the PLGA-PEG-PLGA copolymer is potential thermosensitive in situ gel-forming material for ocular drug delivery, and it may improve the bioavailability, efficacy of some eye drugs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In situ-forming hydrogels--review of temperature-sensitive systems
Ruel-Gariépy, E., & Leroux, J.-C. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.019 · Cited by 1,297
In situ forming parenteral drug delivery systems: an overview
Packhaeuser, C. B., Schnieders, J., Oster, C. G., & Kissel, T. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.003 · Cited by 413
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Gaudana, R., Ananthula, H. K., Parenky, A., & Mitra, A. K. (2010) · The AAPS Journal · doi:10.1208/s12248-010-9183-3 · Cited by 1,406
Self-Healing Injectable Hydrogels for Tissue Regeneration
Bertsch, P., Diba, M., Mooney, D. J., & Leeuwenburgh, S. C. G. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00179 · Cited by 892
Ocular drug delivery systems: An overview
Patel, A. (2013) · World Journal of Pharmacology · doi:10.5497/wjp.v2.i2.47 · Cited by 890
Hydrogels as intelligent materials: A brief review of synthesis, properties and applications
Mahinroosta, M., Jomeh Farsangi, Z., Allahverdi, A., & Shakoori, Z. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.02.004 · Cited by 551
Emerging Role of Hydrogels in Drug Delivery Systems, Tissue Engineering and Wound Management
Jacob, S., Nair, A. B., Shah, J., Sreeharsha, N., Gupta, S., & Shinu, P. (2021) · Pharmaceutics · doi:10.3390/pharmaceutics13030357 · Cited by 485
PEG–PLGA copolymers: Their structure and structure-influenced drug delivery applications
Zhang, K., Tang, X., Zhang, J., Lu, W., Lin, X., Zhang, Y., Tian, B., Yang, H., & He, H. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.026 · Cited by 374
Biomedical applications of hydrogels in drug delivery system: An update
Kesharwani, P., Bisht, A., Alexander, A., Dave, V., & Sharma, S. (2021) · Journal of Drug Delivery Science and Technology · doi:10.1016/j.jddst.2021.102914 · Cited by 288
Gaballa, S. A., Kompella, U. B., Elgarhy, O., Alqahtani, A. M., Pierscionek, B., Alany, R. G., & Abdelkader, H. (2021) · Drug Delivery and Translational Research · doi:10.1007/s13346-020-00843-z · Cited by 255
Smart Hydrogels – Synthetic Stimuli-Responsive Antitumor Drug Release Systems
Kasiński, A., Zielińska-Pisklak, M., Oledzka, E., & Sobczak, M. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s248987 · Cited by 208
Poloxamer-based in situ gelling thermoresponsive systems for ocular drug delivery applications
Soliman, K. A., Ullah, K., Shah, A., Jones, D. S., & Singh, T. R. R. (2019) · Drug Discovery Today · doi:10.1016/j.drudis.2019.05.036 · Cited by 189
“18 Gao, Y. et al. (2010) PLGA–PEG–PLGA hydrogel for ocular drug delivery of 11 dexamethasone acetate.”
BackgroundNovel Strategies for Anterior Segment Ocular Drug Delivery
Cholkar, K., Patel, S. P., Vadlapudi, A. D., & Mitra, A. K. (2013) · Journal of Ocular Pharmacology and Therapeutics · doi:10.1089/jop.2012.0200 · Cited by 189
“have prepared and evaluated a dexamethasone-loaded poly (lactide-co-glycolide)-polyethylene glycol-poly(lactide-coglycolide), ((PLGA)-PEG_PLGA) thermosensitive gelling solution.(79) This formulation improved precorneal residence time and demonstrated 7-fold higher drug levels in aqueous humor (Cmax 125.”
MethodJensen, M. M., Jia, W., Schults, A. J., Isaacson, K. J., Steinhauff, D., Green, B., Zachary, B., Cappello, J., Ghandehari, H., & Oottamasathien, S. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119293 · Cited by 41
Rahvar, M., Ahmadi Lakalayeh, G., Nazeri, N., Marouf, B. T., Shirzad, M., Najafi T. Shabankareh, A., & Ghanbari, H. (2021) · Biomedical Engineering Letters · doi:10.1007/s13534-021-00205-9 · Cited by 15
Metadata
- Authors
- Gao, Y., Sun, Y., Ren, F., & Gao, S.
- Venue
- Drug Development and Industrial Pharmacy
- Publisher
- Informa UK Limited
- Published
- 2010-03-24
- Volume
- 36
- Issue
- 10
- Pages
- 1131-1138
- ISSN
- 0363-9045 (ISSN-L)
- 1520-5762
- OpenAlex
- W2077116757
- Cited by
- 130
- References
- 2
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.