Bioabsorbable Polymers for Implantable Therapeutic Systems
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
For a long time, subcutaneous implantable drug pellets using nondegradable polymers have been used for long-term, continuous drug administration. The procedure requires surgical implantation and removal of the drug-containing devices or polymeric matrices, which has a significant negative impact on the acceptability of the product candidate. In addition, the release profile from such devices is neither constant nor readily controlled in terms of precision of rate of release and duration of action. These facts have led to the research and development of novel, controllable, nonirritating, noncarcinogenic, biocompatible, and bioabsorbable drug delivery systems for overcoming the drawbacks of nondegradable implantable pellets for prolonged continuous release. Biodegradable implantable systems release the drug over a long period of time with simultaneous or subsequent degradation in the tissue of the polymer to harmless constituents, thus avoiding removal once the therapy is complete. This approach has considerably improved patient acceptability and patient compliance. Various bioabsorbable polymers have been evaluated for controlled implantable drug delivery, including hydrogels, copolymers of polylactic and polyglycolic acids, polylactic acid, poly(orthoesters), polyanhydrides, poly(E-caprolactone), and polyurethanes. Their characteristics have been studied using a variety of drugs, like anticancer agents, hormone agonists and antagonists, nonsteroidal anti-inflammatory agents, neuroleptics, contraceptives, and others. The present paper describes the current research on implantable therapeutic systems, the bioabsorbable polymers, and the biologically active agents being used in this approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biodegradable polymers for use in surgery—polyglycolic/poly(actic acid) homo- and copolymers: 1
Gilding, D. K., & Reed, A. M. (1979) · Polymer · doi:10.1016/0032-3861(79)90009-0 · Cited by 1,345
Pitt, G. G., Gratzl, M. M., Kimmel, G. L., Surles, J., & Sohindler, A. (1981) · Biomaterials · doi:10.1016/0142-9612(81)90060-0 · Cited by 857
Miller, R. A., Brady, J. M., & Cutright, D. E. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110507 · Cited by 722
Ramchandani, M., Pankaskie, M., & Robinson, D. (1997) · Journal of Controlled Release · doi:10.1016/s0168-3659(96)01481-2 · Cited by 86
Cited by
Hydrogels in pharmaceutical formulations
Peppas, N. (2000) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/s0939-6411(00)00090-4 · Cited by 4,011
Recent advances in polymeric drug delivery systems
Sung, Y. K., & Kim, S. W. (2020) · Biomaterials Research · doi:10.1186/s40824-020-00190-7 · Cited by 732
Alexis, F. (2005) · Polymer International · doi:10.1002/pi.1697 · Cited by 443
Stimuli-responsive hydrogels in drug delivery and tissue engineering
Sood, N., Bhardwaj, A., Mehta, S., & Mehta, A. (2016) · Drug Delivery · doi:10.3109/10717544.2014.940091 · Cited by 426
Shenoy, D. B., & Amiji, M. M. (2005) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2004.12.010 · Cited by 331
Metadata
- Authors
- Sinha, V. R., & Khosla, L.
- Venue
- Drug Development and Industrial Pharmacy
- Publisher
- Informa UK Limited
- Published
- 1998-01
- Volume
- 24
- Issue
- 12
- Pages
- 1129-1138
- ISSN
- 0363-9045 (ISSN-L)
- 1520-5762
- OpenAlex
- W2099774314
- Cited by
- 51
- References
- 4
- FWCI
- 1.21
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.