Direct comparison of two actigraphy devices with polysomnographically recorded naps in healthy young adults
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
The last 20 yrs have seen a marked increase in studies utilizing actigraphy in free-living environments. The aim of the present study is to directly compare two commercially available actigraph devices with concurrent polysomnography (PSG) during a daytime nap in healthy young adults. Thirty healthy young adults, ages 18-31 (mean 20.77 yrs, SD 3.14 yrs) simultaneously wore AW-64 and GT3X+ devices during a polysomnographically recorded nap. Mann-Whitney U (M-U) test, intraclass correlation coefficients, and Bland-Altman statistic were used to compare total sleep time (TST), sleep onset latency (SOL), wake after sleep onset (WASO), and sleep efficiency (SE) between the two actigraphs and PSG. Epoch-by-epoch (EBE) agreement was calculated to determine accuracy, sensitivity, specificity, predictive values for sleep (PVS) and wake (PVW), and kappa and prevalence- and bias-adjusted kappa (PABAK) coefficients. All frequency settings provided by the devices were examined. For both actigraphs, EBE analysis found accuracy, sensitivity, specificity, PVS, and PVW comparable to previous reports of other similar devices. Kappa and PABAK coefficients showed moderate to high agreement with PSG depending on device settings. The GT3X+ overestimated TST and SE, and underestimated SOL and WASO, whereas no significant difference was found between AW-64 and PSG. However, GT3X+ showed overall better EBE agreements to PSG than AW-64. We conclude that both actigraphs are valid and reliable devices for detecting sleep/wake diurnal patterns. The choice between devices should be based on several parameters as reliability, cost of the device, scoring algorithm, target population, experimental condition, and aims of the study (e.g., sleep and/or physical activity).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
High agreement but low Kappa: I. the problems of two paradoxes
Feinstein, A. R., & Cicchetti, D. V. (1990) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(90)90158-l · Cited by 3,034
The Role of Actigraphy in the Study of Sleep and Circadian Rhythms
Ancoli-Israel, S., Cole, R., Alessi, C., Chambers, M., Moorcroft, W., & Pollak, C. P. (2003) · Sleep · doi:10.1093/sleep/26.3.342 · Cited by 2,751 · cited 1×
“age of epochs scored as wake by the actigraph that were also scored as wake via PSG (Ancoli-Israel et al., 2003).”
MethodByrt, T., Bishop, J., & Carlin, J. B. (1993) · Journal of Clinical Epidemiology · doi:10.1016/0895-4356(93)90018-v · Cited by 2,179
Conducting accelerometer-based activity assessments in field-based research
TROST, S. G., MCIVER, K. L., & PATE, R. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185657.86065.98 · Cited by 2,033
The role and validity of actigraphy in sleep medicine: an update
Sadeh, A. (2011) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2010.10.001 · Cited by 1,415
Morgenthaler, T., Alessi, C., Friedman, L., Owens, J., Kapur, V., Boehlecke, B., Brown, T., Chesson, A., Coleman, J., Lee-Chiong, T., et al. (2007) · Sleep · doi:10.1093/sleep/30.4.519 · Cited by 1,142
Daytime naps, motor memory consolidation and regionally specific sleep spindles
Nishida, M., & Walker, M. P. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000341 · Cited by 531
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
Wearable Sleep Technology in Clinical and Research Settings
DE ZAMBOTTI, M., CELLINI, N., GOLDSTONE, A., COLRAIN, I. M., & BAKER, F. C. (2019) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001947 · Cited by 564
Self-citationThe SBSM Guide to Actigraphy Monitoring: Clinical and Research Applications
Ancoli-Israel, S., Martin, J. L., Blackwell, T., Buenaver, L., Liu, L., Meltzer, L. J., Sadeh, A., Spira, A. P., & Taylor, D. J. (2015) · Behavioral Sleep Medicine · doi:10.1080/15402002.2015.1046356 · Cited by 559
A systematic review of sleep disturbance in anxiety and related disorders
Cox, R. C., & Olatunji, B. O. (2016) · Journal of Anxiety Disorders · doi:10.1016/j.janxdis.2015.12.001 · Cited by 395
Mantua, J., Gravel, N., & Spencer, R. (2016) · Sensors · doi:10.3390/s16050646 · Cited by 314
“As such, we could not conduct epoch-by-epoch analyses of sensitivity and specificity (see [24]).”
BackgroundQuante, M., Kaplan, E. R., Cailler, M., Rueschman, M., Wang, R., Weng, J., Taveras, E. M., & Redline, S. (2018) · Nature and Science of Sleep · doi:10.2147/nss.s151085 · Cited by 298
Associations among late chronotype, body mass index and dietary behaviors in young adolescents
Arora, T., & Taheri, S. (2015) · International Journal of Obesity · doi:10.1038/ijo.2014.157 · Cited by 255
Merikangas, K. R., Swendsen, J., Hickie, I. B., Cui, L., Shou, H., Merikangas, A. K., Zhang, J., Lamers, F., Crainiceanu, C., Volkow, N. D., et al. (2019) · JAMA Psychiatry · doi:10.1001/jamapsychiatry.2018.3546 · Cited by 231
Physical Activity and Sleep Quality in Breast Cancer Survivors: A Randomized Trial
ROGERS, L. Q., COURNEYA, K. S., OSTER, R. A., ANTON, P. M., ROBBS, R. S., FORERO, A., & MCAULEY, E. (2017) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001327 · Cited by 94
“Accelerometer validity has been previously reported (6,38).”
MethodPromises and Challenges in the Use of Consumer-Grade Devices for Sleep Monitoring
Roomkham, S., Lovell, D., Cheung, J., & Perrin, D. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2811735 · Cited by 79
Agreement between sleep diary and actigraphy in a highly educated Brazilian population
Campanini, M. Z., Lopez-Garcia, E., Rodríguez-Artalejo, F., González, A. D., Andrade, S. M., & Mesas, A. E. (2017) · Sleep Medicine · doi:10.1016/j.sleep.2017.04.004 · Cited by 67
Heiland, E. G., Lindh, F., Regan, C., Ekblom, Ö., Kjellenberg, K., Larsen, F. J., Fernström, M., Nyberg, G., Ekblom, M. M., & Helgadóttir, B. (2024) · npj Science of Food · doi:10.1038/s41538-024-00308-4 · Cited by 7
“At night,participantsworetheActigraphGT3X + ontheirleftwrist 33 .”
Testani, D., McMorris, C. A., Clark, C. A., Sanguino, H., Condliffe, E. G., Noel, M. E., Kopala Sibley, D. C., & Brunton, L. K. (2024) · Research in Developmental Disabilities · doi:10.1016/j.ridd.2024.104783 · Cited by 7
Metadata
- Authors
- Cellini, N., Buman, M. P., McDevitt, E. A., Ricker, A. A., & Mednick, S. C.
- Venue
- Chronobiology International
- Publisher
- Informa UK Limited
- Published
- 2013-05-30
- Volume
- 30
- Issue
- 5
- Pages
- 691-698
- ISSN
- 0742-0528 (ISSN-L)
- 1525-6073
- OpenAlex
- W1978579272
- Cited by
- 181
- References
- 11
- FWCI
- 13.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.