Phase Resetting of the Human Circadian Pacemaker with Use of a Single Pulse of Bright Light
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Since the initial studies reporting that light can alter the phase position of the human circadian system, there has been increasing interest in the use of bright light as a tool for manipulating the phase position of the circadian pacemaker. Exposure protocols typically require subjects to receive 2-5 h of exposure over several circadian cycles. As a consequence, bright light treatment can involve a considerable time investment. However, recent studies indicate that a single pulse of bright light can produce significant phase shifts in the circadian pacemaker. If a single pulse of bright light can produce significant phase-shifting effects, multiple-pulse designs may be unnecessary. This study examined the phase-shifting effects of a single 4-h pulse of bright light (12,000 lux) in 14 male and one female subject aged between 19-45 years. With use of a "constant routine" to estimate circadian phase, a single 4-h pulse of light produced significant shifts in the phase of the core temperature rhythm. The timing of the exposure, relative to the core temperature rhythm, determined the degree and direction of the phase shift. Exposure immediately prior to habitual bedtime produced a mean phase delay in the core temperature of 2.39 h (SD = 1.37 h). In contrast, exposure immediately following habitual wake-up produced a mean phase advance of 1.49 h (SD = 2.06 h). In addition, the magnitude of the shift increased the closer the light pulse was to the individual's estimated endogenous core temperature minimum. There was, however, considerable interindividual variability in this relationship.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bright Light Induction of Strong (Type 0) Resetting of the Human Circadian Pacemaker
Czeisler, C. A., Kronauer, R. E., Allan, J. S., Duffy, J. F., Jewett, M. E., Brown, E. N., & Ronda, J. M. (1989) · Science · doi:10.1126/science.2734611 · Cited by 946
Bright light resets the human circadian pacemaker independent of the timing of the sleep-wake cycle
Czeisler, C. A., Allan, J. S., Strogatz, S. H., Ronda, J. M., Sánchez, R., Ríos, C. D., Freitag, W. O., Richardson, G. S., & Kronauer, R. E. (1986) · Science · doi:10.1126/science.3726555 · Cited by 770
Exposure to Bright Light and Darkness to Treat Physiologic Maladaptation to Night Work
Czeisler, C. A., Johnson, M. P., Duffy, J. F., Brown, E. N., Ronda, J. M., & Kronauer, R. E. (1990) · New England Journal of Medicine · doi:10.1056/nejm199005033221801 · Cited by 580
Adaptation to abrupt time shifts of the oscillator(s) controlling human circadian rhythms.
Mills, J. N., Minors, D. S., & Waterhouse, J. M. (1978) · The Journal of Physiology · doi:10.1113/jphysiol.1978.sp012582 · Cited by 285
Cited by
A Phase Response Curve to Single Bright Light Pulses in Human Subjects
Khalsa, S. B. S., Jewett, M. E., Cajochen, C., & Czeisler, C. A. (2003) · The Journal of Physiology · doi:10.1113/jphysiol.2003.040477 · Cited by 1,040
Human responses to bright light of different durations
Chang, A., Santhi, N., St Hilaire, M., Gronfier, C., Bradstreet, D. S., Duffy, J. F., Lockley, S. W., Kronauer, R. E., & Czeisler, C. A. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2011.226555 · Cited by 295
Light Treatment for Sleep Disorders: Consensus Report: VI. Shift Work
Eastman, C. I., Boulos, Z., Terman, M., Campbell, S. S., Dijk, D.-J., & Lewy, A. J. (1995) · Journal of Biological Rhythms · doi:10.1177/074873049501000208 · Cited by 271
Gronfier, C., Wright, K. P., Kronauer, R. E., Jewett, M. E., & Czeisler, C. A. (2004) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00385.2003 · Cited by 212
“Exposure to several hours of bright light for up to 3 consecutive days have been found to reset the endogenous circadian rhythms of core body temperature, cortisol, melatonin, alertness, performance and TSH by up to 12 hours (1, 9, 12, 14-16, 18, 19, 21, 24, 25, 30, 48-50, 55).”
Landry, G. J., & Liu-Ambrose, T. (2014) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2014.00325 · Cited by 84
“Nonetheless randomized controlled trials (RCTs) examining the efficacy of BLT to improve circadian regulation and sleep in older adults with AD were warranted.”
Background
Metadata
- Authors
- Dawson, D., Lack, L., & Morris, M.
- Venue
- Chronobiology International
- Publisher
- Informa UK Limited
- Published
- 1993-01
- Volume
- 10
- Issue
- 2
- Pages
- 94-102
- ISSN
- 0742-0528 (ISSN-L)
- 1525-6073
- OpenAlex
- W2080861726
- Cited by
- 69
- References
- 4
- FWCI
- 1.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Phase Resetting of the Human Circadian Pacemaker with Use of a Single Pulse of Bright Light. https://app.cochat.ai/papers/10.3109/07420529309059697
- The paper
- Dawson, D., Lack, L., & Morris, M. (1993). Phase Resetting of the Human Circadian Pacemaker with Use of a Single Pulse of Bright Light. Chronobiology International. https://doi.org/10.3109/07420529309059697
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.