CoChat

Biocompatibility of a Silicon Based Peripheral Nerve Electrode

Edell, David J., Churchill, John N., Gourley, Ira M. · 1982 · Biomaterials, Medical Devices, and Artificial Organs
Cited by 32

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The biocompatibility of a silicon neuroelectric interface for chronic use in mammalian peripheral nerves was investigated. New Zealand white rabbits were used as the animal model. The implant was made of (110) silicon coated with one micron of silicon dioxide. An anisotropic etch was used to form a grid of ten silicon bars each 40 microns wide and spaced 160 microns apart. A Silastic nerve cuff was molded onto each side of the grid. Using microsurgical techniques, the nerve was transected and sutured into the implant cuff. One implanted rabbit was completely analyzed and is reported here. By 32 days post operatively, the EMG of the affected muscles had partially recovered. The EMG of the affected muscles was indistinguishable from the contralateral control muscles after 150 days. At 332 days, the conduction properties of the implanted nerve confirmed that the nerve was capable of conduction through the silicon grid. Histological observations were consistent with normal peripheral nerve regeneration following microsurgical neurrorhaphy. Seven additional rabbits have been implanted and will be fully analyzed in the future. It was concluded that the silicon peripheral nerve implant described here should be pursued as a substrate for a chronic neuroelectric interface.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3109/10731198209118775

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 32

Metadata

Authors
Edell, D. J., Churchill, J. N., & Gourley, I. M.
Venue
Biomaterials, Medical Devices, and Artificial Organs
Published
1982-01
Volume
10
Issue
2
Pages
103-122
ISSN
0090-5488 (ISSN-L)
OpenAlex
W2283913414
Cited by
32
References
1
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.