Analysis and microelectronic design of tubular electrode arrays intended for chronic, multiple singleunit recording from captured nerve fibres
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Long and snug-fitting cuffs generally provide larger recorded nerve signals.
“In general, long (interelectrode distance close to the wavelength of the action potential) and snug-fitting cuffs provide larger signals (Loeb et al.,”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Loeb et al., 1977
Limits on amplitude and discriminability of single-unit action potentials recordable from nerve fibers inside tubular electrodes may also apply to regenerative electrodes, reducing recorded signal amplitude.
“The limits on the amplitude and discriminability of single-unit action potentials recordable from nerve fibers inside tubular electrodes (Loeb et al., 1977) may also apply to regenerative electrodes, thus decreasing the actual amplitude of recorded signals.”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Loeb et al., 1977
Cites
Electrical Properties of Rocks
(2012) · Springer eBooks · doi:10.1007/springerreference_225620 · Cited by 839 · see citing works
Krogh, A. (1919) · The Journal of Physiology · doi:10.1113/jphysiol.1919.sp001838 · Cited by 633 · see citing works
A miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., Loeb, G. E., Berwald‐Netter, Y., & Okun, L. M. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580 · see citing works
Self-citationAn Integrated-Circuit Approach to Extracellular Microelectrodes
Wise, K. D., Angell, J. B., & Starr, A. (1970) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1970.4502738 · Cited by 544 · see citing works
Preferential selection of central pathways by regenerating optic fibers
Attardi, D. G., & Sperry, R. W. (1963) · Experimental Neurology · doi:10.1016/0014-4886(63)90093-1 · Cited by 507 · see citing works
The electrical properties of metal microelectrodes
Robinson, D. A. (1968) · Proceedings of the IEEE · doi:10.1109/proc.1968.6458 · Cited by 459 · see citing works
Physical Chemistry of Cells and Tissues
(1946) · BMJ · doi:10.1136/bmj.1.4451.651 · Cited by 344 · see citing works
Regeneration in the Mammalian Peripheral Nervous System
Guth, L. (1956) · Physiological Reviews · doi:10.1152/physrev.1956.36.4.441 · Cited by 307 · see citing works
Internode length and fibre diameter in developing and regenerating nerves.
Vizoso, A. D., & Young, J. Z. (1948) · PubMed · Cited by 259 · see citing works
Parylene as a Chronically Stable, Reproducible Microelectrode Insulator
Loeb, G. E., Bak, M. J., Salcman, M., & Schmidt, E. M. (1977) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1977.326115 · Cited by 258 · see citing works
Self-citationConduction velocity and myelin thickness in regenerating nerve fibres
SANDERS, F. K., & Whitteridge, D. (1946) · The Journal of Physiology · doi:10.1113/jphysiol.1946.sp004160 · Cited by 221 · see citing works
The active fiber in a volume conductor
Plonsey, R. (1974) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1974.324406 · Cited by 206 · see citing works
Paintal, A. S. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007948 · Cited by 153 · see citing works
Physical Chemistry of Cells and Tissues.
Höber, R., Hitchcock, D. I., Bateman, J. B., Goddard, D. R., & Fenn, W. O. (1946) · The Journal of Physical Chemistry · doi:10.1021/j150448a010 · Cited by 148 · see citing works
Simultaneous Studies of Firing Patterns in Several Neurons
Gerstein, G. L., & Clark, W. A. (1964) · Science · doi:10.1126/science.143.3612.1325 · Cited by 143 · see citing works
Distribution of nodes and incisures in normal and regenerated nerve fibers
Hiscoe, H. B. (1947) · The Anatomical Record · doi:10.1002/ar.1090990404 · Cited by 139 · see citing works
Paintal, A. S. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008376 · Cited by 109 · see citing works
Loeb, G. E., Walker, A. E., Uematsu, S., & Konigsmark, B. W. (1977) · Journal of Biomedical Materials Research · doi:10.1002/jbm.820110206 · Cited by 95 · see citing works
Self-citationMannard, A., Stein, R. B., & Charles, D. (1974) · Science · doi:10.1126/science.183.4124.547 · Cited by 85 · see citing works
Predicted amplitude and form of action potentials recorded from unmyelinated nerve fibres
Stein, R. B., & Pearson, K. G. (1971) · Journal of Theoretical Biology · doi:10.1016/0022-5193(71)90155-x · Cited by 83 · see citing works
The frequency response of frog muscle spindles under various conditions
Kirkwood, P. A. (1972) · The Journal of Physiology · doi:10.1113/jphysiol.1972.sp009791 · Cited by 63 · see citing works
Marks, W. B., & Loeb, G. E. (1976) · Biophysical Journal · doi:10.1016/s0006-3495(76)85719-0 · Cited by 61 · see citing works
Self-citationDesign, Fabrication, and In Vivo Behavior of Chronic Recording Intracortical Microelectrodes
Salcman, M., & Bak, M. J. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324189 · Cited by 60 · see citing works
THE OXYGEN UPTAKE OF ACTIVE AXONSPreprint
Brink, F., Bronk, D. W., Carlson, F. D., & Connelly, C. M. (1952) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1952.017.01.008 · Cited by 59 · see citing works
METABOLIC REQUIREMENTS OF SYMPATHETIC NEURONSPreprint
Larrabee, M. G., & Bronk, D. W. (1952) · Cold Spring Harbor Symposia on Quantitative Biology · doi:10.1101/sqb.1952.017.01.023 · Cited by 56 · see citing works
ON-LINE SEPARATION OF INTERLEAVED NEURONAL PULSE SEQUENCES
Glaser, E. M., & Marks, W. B. (1968) · Elsevier eBooks · doi:10.1016/b978-0-08-003543-7.50012-4 · Cited by 48 · see citing works
Self-citation(1972) · PubMed · Cited by 43 · see citing works
STUDIES ON THE METABOLISM OF BRAIN SUSPENSIONS
Elliott, K. A. C., & Henry, M. D. (1946) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(17)41315-9 · Cited by 36 · see citing works
A NEW MEASUREMENT OF ACTION CURRENTS DEVELOPED BY SINGLE NODES OF RANVIER
Tasaki, I. (1964) · Journal of Neurophysiology · doi:10.1152/jn.1964.27.6.1199 · Cited by 31 · see citing works
An Instrument for Separation of Multiple-Unit Neuroelectric Signals
Schmidt, E. M. (1971) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1971.4502816 · Cited by 28 · see citing works
Kent, E. W. (1971) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(71)90079-4 · Cited by 21 · see citing works
The neural tube following somite removal
Martin, A. H. (1969) · Cited by 20 · see citing works
Regenerative reconstruction of a tract in a rat's brain
Marks, A. F. (1972) · Experimental Neurology · doi:10.1016/0014-4886(72)90041-6 · Cited by 19 · see citing works
Data Acquisition and Processing in Biology and Medicine
(1968) · Elsevier eBooks · doi:10.1016/c2013-0-01534-4 · Cited by 12 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Navarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · see citing works
Gross, G. W. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326402 · Cited by 327 · see citing works
Silicon microsystems for neuroscience and neural prostheses
Wise, K. D. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511497 · Cited by 194 · see citing works
Edell, D. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325892 · Cited by 177 · see citing works
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175 · see citing works
Regeneration microelectrode array for peripheral nerve recording and stimulation
Kovacs, G. T. A., Storment, C. W., & Rosen, J. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.256422 · Cited by 164 · see citing works
Kovacs, G. T. A., Storment, C. W., Halks-Miller, M., Belczynski, C. R., Santina, C. C. D., Lewis, E. R., & Maluf, N. I. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.293244 · Cited by 161 · see citing works
A micromachined silicon sieve electrode for nerve regeneration applications
Akin, T., Najafi, K., Smoke, R. H., & Bradley, R. M. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284958 · Cited by 144 · see citing works
A review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133 · see citing works
Implantable bioelectronic interfaces for lost nerve functions
Heiduschka, P., & Thanos, S. (1998) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00013-6 · Cited by 126 · see citing works
Simultaneous individual recordings from many cerebral neurons: Techniques and results
Krüger, J. (1983) · Reviews of physiology, biochemistry and pharmacology · doi:10.1007/bfb0033868 · Cited by 99 · see citing works
Tissue-engineered peripheral nerve interfaces
Spearman, B. S., Desai, V. H., Mobini, S., McDermott, M. D., Graham, J. B., Otto, K. J., Judy, J. W., & Schmidt, C. E. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201701713 · Cited by 96 · see citing works
Lewandowska, M., Bakkum, D. J., Rompani, S. B., & Hierlemann, A. R. (2015) · PLoS ONE · doi:10.1371/journal.pone.0118514 · Cited by 94 · see citing works
Microchannels as Axonal Amplifiers
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.909533 · Cited by 76 · see citing works
Long Micro-Channel Electrode Arrays: A Novel Type of Regenerative Peripheral Nerve Interface
Lacour, S. P., Fitzgerald, J. J., Lago, N., Tarte, E., McMahon, S., & Fawcett, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2031241 · Cited by 75 · see citing works
FitzGerald, J. J., Lago, N., Benmerah, S., Serra, J., Watling, C. P., Cameron, R. E., Tarte, E., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/016010 · Cited by 73 · see citing works
Long term chronic recordings from peripheral sensory fibers using a sieve electrode array
Bradley, R. M., Cao, X., Akin, T., & Najafi, K. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(97)02225-5 · Cited by 69 · see citing works
Solid-state microsensors for cortical nerve recordings
Najafi, K. (1994) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/51.294009 · Cited by 67 · see citing works
Early interfaced neural activity from chronic amputated nerves
Garde, K. (2009) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.005.2009 · Cited by 56 · see citing works
Compound sensory action potential in normal and pathological human nerves
Krarup, C. (2003) · Muscle & Nerve · doi:10.1002/mus.10524 · Cited by 51 · see citing works
Wallman, L. (2001) · Biomaterials · doi:10.1016/s0142-9612(00)00342-2 · Cited by 49 · see citing works
A review of printed circuit microelectrodes and their production
PICKARD, R. S. (1979) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(79)90019-0 · Cited by 47 · see citing works
Microchannel Electrodes for Recording and Stimulation: In Vitro Evaluation
FitzGerald, J. J., Lacour, S. P., McMahon, S. B., & Fawcett, J. W. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2013960 · Cited by 45 · see citing works
Functional regeneration of glossopharyngeal nerve through micromachined sieve electrode arrays
Bradley, R. M., Smoke, R. H., Akın, T., & Najafi, K. (1992) · Brain Research · doi:10.1016/0006-8993(92)91031-9 · Cited by 44 · see citing works
Santina, C. C. D., Kovacs, G. T. A., & Lewis, E. R. (1997) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(96)00159-8 · Cited by 34 · see citing works
Zariffa, J., Nagai, M. K., Daskalakis, Z. J., & Popović, M. R. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023301 · Cited by 32 · see citing works
Frazier, A. B., O'Brien, D. P., & Allen, M. G. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1993.296923 · Cited by 32 · see citing works
Biocompatibility of a Silicon Based Peripheral Nerve Electrode
Edell, D. J., Churchill, J. N., & Gourley, I. M. (1982) · Biomaterials Medical Devices and Artificial Organs · doi:10.3109/10731198209118775 · Cited by 32 · see citing works
Flexible printed-circuit probe for electrophysiology
Pickard, R. S., Joseph, P., Collins, A. J., & Hicks, R. C. J. (1979) · Medical & Biological Engineering & Computing · doi:10.1007/bf02440939 · Cited by 28 · see citing works
Printed circuit microelectrodes
PICKARD, R. S. (1979) · Trends in Neurosciences · doi:10.1016/0166-2236(79)90101-2 · Cited by 23 · see citing works
Criteria for evaluating multiunit spike separation techniques
Heetderks, W. (1978) · Biological Cybernetics · doi:10.1007/bf00337278 · Cited by 19 · see citing works
A micromachined silicon sieve electrode for nerve regeneration applications
Akın, T., & Najafi, K. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148818 · Cited by 19 · see citing works
3D Microstructured Carbon Nanotube Electrodes for Trapping and Recording Electrogenic Cells
Cools, J., Copic, D., Luo, Z., Callewaert, G., Braeken, D., & Volder, M. F. L. D. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201701083 · Cited by 17 · see citing works
Long-Term Neuroelectric Signal Recording from Severed Nerves
Luca, C. J. D., Gilmore, L., Bloom, L. J., Thomson, S. J., Cudworth, A. L., & Glimcher, M. J. (1982) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1982.324953 · Cited by 16 · see citing works
Regeneration microelectrode arrays for direct interface to nerves
Kovacs, G. T. A. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1991.148814 · Cited by 12 · see citing works
A Microclip Peripheral Nerve Interface (μcPNI) for Bioelectronic Interfacing with Small Nerves
Rowan, C. C., Graudejus, O., & Otchy, T. M. (2021) · Advanced Science · doi:10.1002/advs.202102945 · Cited by 11 · see citing works
Effects of the choice of reference on the selectivity of a multi-contact nerve cuff electrode
Koh, R. G. L., & Zariffa, J. (2016) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591713 · Cited by 5 · see citing works
Regenerative Electrodes for Peripheral Nerve Interfacing
Zellmer, E. R., & Moran, D. W. (2021) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_18-1 · Cited by 4 · see citing works
Chapter 2 Physiology and function
(2006) · Handbook of clinical neurophysiology · doi:10.1016/s1567-4231(09)70063-2 · Cited by 3 · see citing works
Spiral peripheral nerve interface; updated fabrication process of the regenerative implant
Barrett, R., Benmerah, S., Frommhold, A., & Tarte, E. J. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609614 · Cited by 3 · see citing works
Micromachined metallic pipettes and bioanalysis systems
Frazier, A. B., Gale, B. K., & Papautsky, I. (2002) · International Symposium on Micro-NanoMechatronics and Human Science · doi:10.1109/mhs.1997.768849 · Cited by 3 · see citing works
Regeneration-Type Peripheral Nerve Interfaces for Direct Man/Machine Communication
Gregory, T., & Joseph, M. (1993) · Springer eBooks · doi:10.1007/978-3-642-58069-7_35 · Cited by 3 · see citing works
Regenerative Electrodes for Peripheral Nerve Interfacing
Zellmer, E. R., & Moran, D. W. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_18 · Cited by 1 · see citing works
A phantom axon setup for validating models of action potential recordings
Rossel, O., Soulier, F., Bernard, S., Guiraud, D., & Cathébras, G. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-016-1463-3 · Cited by 1 · see citing works
Regenerative Peripheral Neurointerfacing Of Upper Extremity Prostheses
Garde, K. (2008) · UTA ResearchCommons (University of Texas Arlington)
Lago, N. (2006) · TDX (Tesis Doctorals en Xarxa)
- Authors
- Loeb, G. E., Marks, W. B., & Beatty, P. G.
- Affiliations
- National Institutes of Health (US)
- ORCID
- Loeb, G. E.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 1977-03
- Volume
- 15
- Issue
- 2
- Pages
- 195-201
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2122927536
- Cited by
- 46
- References
- 34
- Citations by year
- 2023: 1 · 2021: 2 · 2019: 1 · 2017: 2 · 2016: 3 · 2015: 1 · 2013: 1 · 2012: 1
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Medical & Biological Engineering & Computing (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
- Keywords
- single-unit recording, chronic neural recording, signal-to-noise ratio, nerve regeneration, microelectrode design
- MeSH terms
- Action Potentials, Electronics, Microelectrodes, Nerve Regeneration, Neurons
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review