Load Bearing Characteristics of the Patello-Femoral Joint
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This study of normal patello-femoral biomechanics defines some functional specifications which may be useful in future total knee prosthesis design. Serial lateral X-rays of 15 fresh knees and their patellar mechanisms at several flexion angles provided definition of the direction of the resolved patello-femoral forces. Assuming that the patella acts as a frictionless pulley, the magnitude of the patello-femoral forces during several activities was calculated using data from Morrison (1970) and Smidt (1973). It ranged between 421 and 3420 newtons for the various activities and for isometric exercise. A methylene blue contact print technique was used to measure the bearing areas. These data indicate that between 13 and 38 per cent of the patellar surface bears joint loadings. Patello-femoral contact stresses were calculated to range from 1.28 to 12.6 N/mm2. A 696 new-ton man climbing stairs would, for example, generate a patello-femoral force of 1754 newtons and would experience patello-femoral contact stresses between 3.73 and 6.87 N/mm2. Stress values were equal to or in excess of anticipated tibial-femoral stresses. The high patello-femoral load values, the small bearing surfaces, and the consequent significant stress magnitudes indicate the need for caution in development of a patello-femoral joint prosthetic replacement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Role of the Menisci in Force Transmission Across the Knee
Walker, P. S., & Erkiuan, M. J. (1975) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-197506000-00027 · Cited by 1,117
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,055
Biomechanical analysis of knee flexion and extension
Smidt, G. L. (1973) · Journal of Biomechanics · doi:10.1016/0021-9290(73)90040-7 · Cited by 511
Tibiofemoral Contact Area-Determination and Implications
KETTELKAMP, D. B., & JACOBS, A. W. (1972) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197254020-00013 · Cited by 247
The mechanics of muscle function in locomotion
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90016-3 · Cited by 151
Cited by
Interaction between active and passive knee stabilizers during level walking
Schipplein, O. D., & Andriacchi, T. P. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090114 · Cited by 1,019
A mathematical model of the patellofemoral joint
van Eijden, T. M. G. J., Kouwenhoven, E., Verburg, J., & Weijs, W. A. (1986) · Journal of Biomechanics · doi:10.1016/0021-9290(86)90154-5 · Cited by 321
Patellofemoral stress during walking in persons with and without patellofemoral pain
HEINO BRECHTER, J., & POWERS, C. M. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200210000-00009 · Cited by 309
Biomechanical considerations in patellofemoral joint rehabilitation
Steinkamp, L. A., Dillingham, M. F., Markel, M. D., Hill, J. A., & Kaufman, K. R. (1993) · The American Journal of Sports Medicine · doi:10.1177/036354659302100319 · Cited by 304
Brechter, J. H., & Powers, C. M. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00090-5 · Cited by 274
Powers, C. M., Bolgla, L. A., Callaghan, M. J., Collins, N., & Sheehan, F. T. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.0301 · Cited by 222
In Vivo Kinematic Analysis of a Mobile Bearing Total Knee Prosthesis
Stiehl, J. B., Dennis, D. A., Komistek, R. D., & Keblish, P. A. (1997) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199712000-00010 · Cited by 185
Interaction between intrinsic knee mechanics and the knee extensor mechanism
Draganich, L. F., Andriacchi, T. P., & Andersson, G. B. J. (1987) · Journal of Orthopaedic Research · doi:10.1002/jor.1100050409 · Cited by 182
The biomechanics of the human patella during passive knee flexion
Heegaard, J., Leyvraz, P. F., Curnier, A., Rakotomanana, L., & Huiskes, R. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00059-q · Cited by 180
“Accordingly, several studies have reported patello-femoral contact characteristics (Ahmed et al., 1983; Fujikawa et al., 1983; Goodfellow et al., 1976; Goymann and Mueller, 1974; Hille et al., 1985; Huberti and Hayes, 1984; Matthews et al., 1977; Seedhom et al., 1979; Shoji, 1974; Soslowsky et al., 1990): near extensi…”
BackgroundInfluentialApplied Biomechanics of the Patella
Grelsamer, R. P., & Weinstein, C. H. (2001) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-200108000-00003 · Cited by 169
The effects of axial and multi-plane loading of the extensor mechanism on the patellofemoral joint
Powers, C. M., Lilley, J. C., & Lee, T. Q. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(98)00013-8 · Cited by 158
Zhang, Y., Hunter, D. J., Nevitt, M. C., Xu, L., Niu, J., Lui, L., Yu, W., Aliabadi, P., & Felson, D. T. (2004) · Arthritis & Rheumatism · doi:10.1002/art.20127 · Cited by 153
Patellofemoral joint kinetics while squatting with and without an external load
Wallace, D. A., Salem, G. J., Salinas, R., & Powers, C. M. (2002) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2002.32.4.141 · Cited by 148
“using both static biomechanical models and dynamic ones.(14,19,9) Reilly and Martens,(19) as well as Heino Brechter and Powers,(9) reported that average peak patellofemoral joint reaction forces were approximately 3.”
Method
Metadata
- Authors
- Matthews, L. S., Sonstegard, D. A., & Henke, J. A.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 1977-01
- Volume
- 48
- Issue
- 5
- Pages
- 511-516
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2061064028
- Cited by
- 202
- References
- 5
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.