Strain, stress and stretch of peripheral nerve Rabbit experiments in vitro and in vivo
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Mechanical stretching is known to cause morphologic and functional changes in peripheral nerve. The points at which these changes occur, however, are not clearly defined and reported data are conflicting. The studies presented in this paper provide a basic understanding of the biomechanical properties, stretch-injury patterns, and changes of conduction properties of peripheral nerves due to stretching. Our studies showed that peripheral nerves exhibited non-linear stress-strain characteristics when placed under tension. Initially, under tension, the nerve had a low modulus that increased gradually with increasing strain until reaching a maximal value. When the nerve failed under tension, the perineurium inside the nerve ruptured, but the exterior of the nerve remained intact. Our results also show that a peripheral nerve in situ was under significant strain, but minimal in situ stress (less than 0.05 MPa). The in situ strain might vary with limb position, but did not appear to exceed the limit beyond which substantial tension or stress would be developed in the nerve. The time-dependent viscoelastic behavior of peripheral nerves were also characterized. The maintenance of small in situ stresses suggests that sustained increases in tension could be adversely affecting the electrophysiologic properties of the nerve. Indeed, marked alteration of conduction properties resulted from even a small stretch of 6 percent beyond the in situ length of the nerve, or stress less than 10 percent of the ultimate strength of the nerve.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Current Problems of Lower Vertebrate Phylogeny
Romanes, G. J. (1969) · Journal of Anatomy · Cited by 1,830
Surgical Disorders of the Peripheral Nerves
(1972) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1972.tb88216.x · Cited by 749
Injuries of Nerves and their Consequences
Mitchell, S. W. (1872) · The American Journal of the Medical Sciences · doi:10.1097/00000441-187207000-00024 · Cited by 548
Lundborg, G. (1988) · Medical Entomology and Zoology · Cited by 482
Lundborg, G. (1975) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197557070-00011 · Cited by 416
Lundborg, G., & Rydevik, B. (1973) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.55b2.390 · Cited by 408 · cited 1×
“In a study of intraneural blood flow in the rabbit tibial nerve during gradual stretching (Lundborg and Rydevik 1973), it was shown that impairment of venular blood flow was induced when a nerve was stretched 8 percent beyond in vivo length.”
BackgroundLundborg, G., & Rydevik, B. L. (1973) · PubMed · Cited by 403
Plewes, J. (1989) · Injury · doi:10.1016/0020-1383(89)90135-6 · Cited by 376
Rydevik, B., & Lundborg, G. (1977) · Scandinavian Journal of Plastic and Reconstructive Surgery · doi:10.3109/02844317709025516 · Cited by 289
Measurement of mechanical properties of ligament substance from a bone‐ligament‐bone preparation
Woo, S. L., Gomez, M. A., Seguchi, Y., Endo, C. M., & Akeson, W. H. (1983) · Journal of Orthopaedic Research · doi:10.1002/jor.1100010104 · Cited by 283
Cited by
Gu, X., Ding, F., Yang, Y., & Liu, J. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.11.002 · Cited by 583
Vat polymerization-based bioprinting—process, materials, applications and regulatory challenges
Ng, W. L., Lee, J. M., Zhou, M., Chen, Y.-W., Lee, K.-X. A., Yeong, W. Y., & Shen, Y.-F. (2020) · Biofabrication · doi:10.1088/1758-5090/ab6034 · Cited by 402
Topp, K. S., & Boyd, B. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.1.92 · Cited by 361
Suprascapular Nerve Entrapment*
CUMMINS, C. A., MESSER, T. M., & NUBER, G. W. (2000) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200003000-00013 · Cited by 265
Rapid continuous 3D printing of customizable peripheral nerve guidance conduits
Zhu, W., Tringale, K. R., Woller, S. A., You, S., Johnson, S., Shen, H., Schimelman, J., Whitney, M., Steinauer, J., Xu, W., et al. (2018) · Materials Today · doi:10.1016/j.mattod.2018.04.001 · Cited by 253
Nerve and tendon gliding exercises and the conservative management of carpal tunnel syndrome
Rozmaryn, L. M., Dovelle, S., Rothman, E. R., Gorman, K., Olvey, K. M., & Bartko, J. J. (1998) · Journal of Hand Therapy · doi:10.1016/s0894-1130(98)80035-5 · Cited by 214
Shacklock, M. (1995) · Physiotherapy · doi:10.1016/s0031-9406(05)67024-1 · Cited by 202
3D multi-channel bi-functionalized silk electrospun conduits for peripheral nerve regeneration
Dinis, T. M., Elia, R., Vidal, G., Dermigny, Q., Denoeud, C., Kaplan, D. L., Egles, C., & Marin, F. (2015) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.09.029 · Cited by 191
Nerve trunk pain: physical diagnosis and treatment
Hall, T. M., & Elvey, R. L. (1999) · Manual Therapy · doi:10.1054/math.1999.0172 · Cited by 158
Rapid prototyping of soft bioelectronic implants for use as neuromuscular interfaces
Afanasenkau, D., Kalinina, D., Lyakhovetskii, V., Tondera, C., Gorsky, O., Moosavi, S., Pavlova, N., Merkulyeva, N., Kalueff, A. V., Minev, I. R., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00615-7 · Cited by 148
Chronic multichannel neural recordings from soft regenerative microchannel electrodes during gait
Musick, K. M., Rigosa, J., Narasimhan, S., Wurth, S., Capogrosso, M., Chew, D. J., Fawcett, J. W., Micera, S., & Lacour, S. P. (2015) · Scientific Reports · doi:10.1038/srep14363 · Cited by 70
Functional and mechanical evaluation of nerve stretch injury
Rickett, T., Connell, S., Bastijanic, J., Hegde, S., & Shi, R. (2011) · Journal of Medical Systems · doi:10.1007/s10916-010-9468-1 · Cited by 64
“The resulting decreases in conduction amplitude were comparable to literature values for in vivo and ex vivo experiments [2, 7, 12].”
BackgroundResultInfluentialBiomechanical and functional variation in rat sciatic nerve following cuff electrode implantation
Restaino, S. M., Abliz, E., Wachrathit, K., Krauthamer, V., & Shah, S. B. (2014) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-11-73 · Cited by 44
“These thresholds are typically estimated to be 8-15%, though there is high variability across and even within species [47-55].”
BackgroundVučković, A., Struijk, J. J., & Rijkhoff, N. J. M. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345814 · Cited by 16
“Stretching of the nerve above that limit leads to changes in the conduction properties of the nerve (KWAN et al., 1992) and to nerve damage.”
Background
Metadata
- Authors
- Kwan, M. K., Wall, E. J., Massie, J., & Garfin, S. R.
- Venue
- Acta Orthopaedica Scandinavica
- Published
- 1992-01
- Volume
- 63
- Issue
- 3
- Pages
- 267-272
- ISSN
- 0001-6470 (ISSN-L)
- OpenAlex
- W2158824489
- Cited by
- 262
- References
- 22
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.