The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
A brain-computer interface for long-term independent home use
Abstract
Our objective was to develop and validate a new brain-computer interface (BCI) system suitable for long-term independent home use by people with severe motor disabilities. The BCI was used by a 51-year-old male with ALS who could no longer use conventional assistive devices. Caregivers learned to place the electrode cap, add electrode gel, and turn on the BCI. After calibration, the system allowed the user to communicate via EEG. Re-calibration was performed remotely (via the internet), and BCI accuracy assessed in periodic tests. Reports of BCI usefulness by the user and the family were also recorded. Results showed that BCI accuracy remained at 83% (r = -.07, n.s.) for over 2.5 years (1.4% expected by chance). The BCI user and his family state that the BCI had restored his independence in social interactions and at work. He uses the BCI to run his NIH-funded research laboratory and to communicate via e-mail with family, friends, and colleagues. In addition to this first user, several other similarly disabled people are now using the BCI in their daily lives. In conclusion, long-term independent home use of this BCI system is practical for severely disabled people, and can contribute significantly to quality of life and productivity.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the one hand, the emergence of interfaces based on evoked responses (P300, steady-state visually evoked potentials [SSVEP]) as the most efficient BCI solution for communication [13–16] has promoted the use of machine learning because the margin for humans to learn to regulate evoked potentials is considered to be narrow.”
From The Cybathlon BCI race: Successful longitudinal mutual learning with two tetraplegic users (2018) · cites this paper as [13]
Citations
Cites
Draper, N. R., & Smith, H. (2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,993
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Self-citationCedarbaum, J. M., Stambler, N., Malta, E., Fuller, C., Hilt, D., Thurmond, B., & Nakanishi, A. (1999) · Journal of the Neurological Sciences · doi:10.1016/s0022-510x(99)00210-5 · Cited by 3,307
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Hochberg, L. R., Serruya, M. D., Friehs, G. M., Mukand, J. A., Saleh, M., Caplan, A. H., Branner, A., Chen, D., Penn, R. D., & Donoghue, J. P. (2006) · Nature · doi:10.1038/nature04970 · Cited by 3,295
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
BCI2000: A General-Purpose Brain-Computer Interface (BCI) System
Schalk, G., McFarland, D. J., Hinterberger, T., Birbaumer, N., & Wolpaw, J. R. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.827072 · Cited by 3,129
Self-citationApplied Regression Analysis (2nd ed).
de Carvalho, J. F., Draper, N. R., & Smith, H. (1981) · Journal of the American Statistical Association · doi:10.2307/2287608 · Cited by 3,054
Clarke, G. M., Draper, N. R., & Smith, H. (1982) · Journal of the Royal Statistical Society Series A (General) · doi:10.2307/2982106 · Cited by 1,797
A spelling device for the paralysed
Birbaumer, N., Ghanayim, N., Hinterberger, T., Iversen, I., Kotchoubey, B., Kübler, A., Perelmouter, J., Taub, E., & Flor, H. (1999) · Nature · doi:10.1038/18581 · Cited by 1,577
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K., & Wijesinghe, R. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,231
Flagged first, then by citations
Research works printed but not linked: 2
- Townsend GT, Clin Neurophysiol
- Lule D, 2008, Dtsch Arztebl Int, 105, 397
Cited by
Sorted by citations
Items 101–200 of 399
Decoding Finger Movements from ECoG Signals Using Switching Linear Models
Flamary, R., & Rakotomamonjy, A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00029 · Cited by 70
Increasing BCI communication rates with dynamic stopping towards more practical use: an ALS study
Mainsah, B. O., Collins, L. M., Colwell, K. A., Sellers, E. W., Ryan, D. B., Caves, K. M., & Throckmorton, C. S. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016013 · Cited by 69
Self-citationBrain-computer interfaces for communication
Vansteensel, M. J., & Jarosiewicz, B. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00007-x · Cited by 72
Botrel, L., Holz, E. M., & Kübler, A. (2015) · Brain-Computer Interfaces · doi:10.1080/2326263x.2015.1100038 · Cited by 68
Rapid P300 brain-computer interface communication with a head-mounted display
Käthner, I., Kübler, A., & Halder, S. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00207 · Cited by 67
Jin, W., Zhu, X., Qian, L., Wu, C., Yang, F., Zhan, D., Kang, Z., Luo, K., Meng, D., & Xu, G. (2024) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2024.1431815 · Cited by 71
Wireless EEG with individualized channel layout enables efficient motor imagery training
Zich, C., Vos, M. D., Kranczioch, C., & Debener, S. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.07.007 · Cited by 63
Kübler, A., Holz, E. M., Sellers, E. W., & Vaughan, T. M. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.03.036 · Cited by 63
Self-citationLim, J., Lee, J., Hwang, H., Kim, D. H., & Im, C. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.05.012 · Cited by 62
Brain-Computer Interfaces for Communication: Preferences of Individuals With Locked-in Syndrome
Branco, M. P., Pels, E. G. M., Sars, R. H., Aarnoutse, E. J., Ramsey, N. F., Vansteensel, M. J., & Nijboer, F. (2021) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968321989331 · Cited by 61
Removal of Eye Blink Artifacts From EEG Signals Using Sparsity
Sreeja, S. R., Sahay, R. R., Samanta, D., & Mitra, P. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2771783 · Cited by 60
Vansteensel, M. J., Klein, E. P., van Thiel, G. J. M. W., Gaytant, M. A., Simmons, Z., Wolpaw, J. R., & Vaughan, T. M. (2022) · Journal of Neurology · doi:10.1007/s00415-022-11464-6 · Cited by 62
Self-citationEEG-Based Brain-Computer Interfaces
Wang, Y., Nakanishi, M., & Zhang, D. (2019) · Advances in experimental medicine and biology · doi:10.1007/978-981-13-2050-7_2 · Cited by 63
Brunner, C., Andreoni, G., Bianchi, L., Blankertz, B., Breitwieser, C., Kanoh, S., Kothe, C. A., Lécuyer, A., Makeig, S., Mellinger, J., et al. (2012) · Biological and medical physics series · doi:10.1007/978-3-642-29746-5_16 · Cited by 59
Technology transfer of brain-computer interfaces as assistive technology: Barriers and opportunities
Nijboer, F. (2015) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2014.11.001 · Cited by 63
Schettini, F., Riccio, A., Simione, L., Liberati, G., Caruso, M., Frasca, V., Calabrese, B., Mecella, M., Pizzimenti, A., Inghilleri, M., et al. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.05.027 · Cited by 58
Large-Scale Assessment of a Fully Automatic Co-Adaptive Motor Imagery-Based Brain Computer Interface
Acqualagna, L., Botrel, L., Vidaurre, C., Kübler, A., & Blankertz, B. (2016) · PLoS ONE · doi:10.1371/journal.pone.0148886 · Cited by 61
Brain–computer interface use is a skill that user and system acquire together
McFarland, D. J., & Wolpaw, J. R. (2018) · PLoS Biology · doi:10.1371/journal.pbio.2006719 · Cited by 64
Self-citationProceedings of the Third International Workshop on Advances in Electrocorticography
Ritaccio, A. L., Beauchamp, M. S., Bosman, C. A., Brunner, P., Chang, E. F., Crone, N. E., Gunduz, A., Gupta, D., Knight, R. T., Leuthardt, E. C., et al. (2012) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2012.09.016 · Cited by 56
P300-Based Asynchronous Brain Computer Interface for Environmental Control System
Aydın, E. A., Bay, Ö. F., & Güler, İ. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2690801 · Cited by 57
A Novel Three-Dimensional P300 Speller Based on Stereo Visual Stimuli
Qu, J., Wang, F., Xia, Z., Yu, T., Xiao, J., Yu, Z., Gu, Z., & Li, Y. (2018) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2018.2799525 · Cited by 58
Effects of resting heart rate variability on performance in the P300 brain-computer interface
Kaufmann, T., Vögele, C., Sütterlin, S., Lukito, S., & Kübler, A. (2011) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2011.11.018 · Cited by 54
Brain–computer interfaces in the completely locked-in state and chronic stroke
Chaudhary, U., Birbaumer, N., & Ramos‐Murguialday, A. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.019 · Cited by 58
Driving a Semiautonomous Mobile Robotic Car Controlled by an SSVEP-Based BCI
Stawicki, P., Gembler, F. W., & Volosyak, I. (2016) · Computational Intelligence and Neuroscience · doi:10.1155/2016/4909685 · Cited by 54
Decoding task engagement from distributed network electrophysiology in humans
Provenza, N. R., Paulk, A. C., Peled, N., Restrepo, M. I., Cash, S. S., Dougherty, D. D., Eskandar, E. N., Borton, D. A., & Widge, A. S. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab2c58 · Cited by 51
Performance assessment in brain-computer interface-based augmentative and alternative communication
Thompson, D. E., Blain‐Moraes, S., & Huggins, J. E. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-43 · Cited by 52
Liberati, G., Pizzimenti, A., Simione, L., Riccio, A., Schettini, F., Inghilleri, M., Mattia, D., & Cincotti, F. (2015) · Applied Ergonomics · doi:10.1016/j.apergo.2015.03.012 · Cited by 53
McCullagh, P. J., Lightbody, G., Żygierewicz, J., & Kernohan, G. W. (2013) · Neuroethics · doi:10.1007/s12152-013-9188-6 · Cited by 51
Language Model Applications to Spelling with Brain-Computer Interfaces
Mora-Cortes, A., Manyakov, N. V., Chumerin, N., & Hulle, M. M. V. (2014) · Sensors · doi:10.3390/s140405967 · Cited by 50
Shishkin, S. L., Nuzhdin, Y. O., Svirin, E. P., Trofimov, A. G., Fedorova, A. A., Kozyrskiy, B. L., & Velichkovsky, B. M. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00528 · Cited by 52
Formento, E., Botros, P., & Carmena, J. M. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac35ac · Cited by 54
Lin, Y., Wang, Y., Wei, C.-S., & Jung, T. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00182 · Cited by 46
Fager, S. K., & Burnfield, J. M. (2013) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2013.787124 · Cited by 46
Käthner, I., Halder, S., Hintermüller, C., Espinosa, A., Guger, C., Miralles, F., Vargiu, E., Dauwalder, S., Rafael-Palou, X., Solà, M., et al. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00286 · Cited by 46
Autonomous Parameter Adjustment for SSVEP-Based BCIs with a Novel BCI Wizard
Gembler, F. W., Stawicki, P., & Volosyak, I. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00474 · Cited by 45
Alazrai, R., Alwanni, H., Baslan, Y., Alnuman, N., & Daoud, M. I. (2017) · Sensors · doi:10.3390/s17091937 · Cited by 46
Application of P300 Event-Related Potential in Brain-Computer Interface
Haider, A., & Fazel-Rezai, R. (2017) · InTech eBooks · doi:10.5772/intechopen.69309 · Cited by 45
Shahriari, Y., Vaughan, T. M., McCane, L. M., Allison, B. Z., Wolpaw, J. R., & Krusienski, D. J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab22ea · Cited by 45
Self-citationPeters, B., Bieker, G., Heckman, S. M., Huggins, J. E., Wolf, C., Zeitlin, D., & Fried-Oken, M. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.03.037 · Cited by 44
Holz, E. M., Botrel, L., & Kübler, A. (2015) · Brain-Computer Interfaces · doi:10.1080/2326263x.2015.1100048 · Cited by 45
Annen, J., Laureys, S., & Gosseries, O. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00011-1 · Cited by 45
Amyotrophic lateral sclerosis progression and stability of brain-computer interface communication
Silvoni, S., Cavinato, M., Volpato, C., Ruf, C. A., Birbaumer, N., & Piccione, F. (2013) · Amyotrophic Lateral Sclerosis and Frontotemporal Degeneration · doi:10.3109/21678421.2013.770029 · Cited by 43
Workshops of the Fifth International Brain-Computer Interface Meeting: Defining the Future
Huggins, J. E., Guger, C., Allison, B. Z., Anderson, C. W., Batista, A. P., Brouwer, A.-M., Brunner, C., Chavarriaga, R., Fried-Oken, M. B., Gunduz, A., et al. (2014) · Brain-Computer Interfaces · doi:10.1080/2326263x.2013.876724 · Cited by 43
Concentration on performance with P300-based BCI systems: A matter of interface features
da Silva‐Sauer, L., Aguayo, L. V., de la Torre‐Luque, A., Ron-Angevín, R., & Varona-Moya, S. (2015) · Applied Ergonomics · doi:10.1016/j.apergo.2015.08.002 · Cited by 42
Offline analysis of context contribution to ERP-based typing BCI performance
Orhan, U., Deniz Erdogmus, B., Brian Roark, A., Oken, B., & Fried-Oken, M. B. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/6/066003 · Cited by 41
A visual parallel-BCI speller based on the time–frequency coding strategy
Xu, M., Chen, L., Zhang, L., Qi, H., Ma, L., Tang, J., Wan, B., & Ming, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026014 · Cited by 42
Shishkin, S. L., Ganin, I. P., & Kaplan, A. (2011) · Neuroscience Letters · doi:10.1016/j.neulet.2011.03.089 · Cited by 41
Peters, B., Eddy, B. S., Galvin-McLaughlin, D., Betz, G., Oken, B., & Fried-Oken, M. B. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.952380 · Cited by 40
Augmentative and Alternative Communication for People with Progressive Neuromuscular Disease
Ball, L. J., Fager, S. K., & Fried-Oken, M. B. (2012) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2012.06.003 · Cited by 41
Ganin, I. P., Shishkin, S. L., & Kaplan, A. (2013) · PLoS ONE · doi:10.1371/journal.pone.0077755 · Cited by 39
Channel Selection Based on Phase Measurement in P300-Based Brain-Computer Interface
Xu, M., Qi, H., Ma, L., Sun, C., Zhang, L., Wan, B., Yin, T., & Ming, D. (2013) · PLoS ONE · doi:10.1371/journal.pone.0060608 · Cited by 39
Fabio Aloise, A., Schettini, F., Aricò, P., Salinari, S., Guger, C., Rinsma, J., Aiello, M., Donatella Mattia, A., & Febo Cincotti, A. (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200406 · Cited by 39
Exploring motion VEPs for gaze-independent communication
Schaeff, S., Treder, M. S., Venthur, B., & Blankertz, B. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/4/045006 · Cited by 39
Pitt, K. M., & Brumberg, J. S. (2018) · American Journal of Speech-Language Pathology · doi:10.1044/2018_ajslp-17-0135 · Cited by 41
Online Home Appliance Control Using EEG-Based Brain–Computer Interfaces
Kim, M., Kim, M., Hwang, M., Kim, H., Cho, J., & Kim, S.-P. (2019) · Electronics · doi:10.3390/electronics8101101 · Cited by 39
A User Centred Approach for Bringing BCI Controlled Applications to End-Users
Kübler, A., Holz, E. M., Kaufmann, T., & Zickler, C. (2013) · InTech eBooks · doi:10.5772/55802 · Cited by 38
Exploring Combinations of Auditory and Visual Stimuli for Gaze-Independent Brain-Computer Interfaces
An, X., Höhne, J., Ming, D., & Blankertz, B. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111070 · Cited by 38
Gutiérrez-Martínez, J., Mercado-Gutierrez, J. A., Carvajal-Gámez, B. E., Rosas‐Trigueros, J. L., & Contreras-Martinez, A. E. (2021) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2021.772837 · Cited by 41
A plug-and-play brain-computer interface to operate commercial assistive technology
Thompson, D. E., Gruis, K. L., & Huggins, J. E. (2013) · Disability and Rehabilitation Assistive Technology · doi:10.3109/17483107.2013.785036 · Cited by 37
Brain-controlled muscle stimulation for the restoration of motor function
Éthier, C., & Miller, L. E. (2014) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.10.014 · Cited by 40
Combaz, A., & Hulle, M. M. V. (2015) · PLoS ONE · doi:10.1371/journal.pone.0121481 · Cited by 36
Interfacing brain with computer to improve communication and rehabilitation after brain damage
Riccio, A., Pichiorri, F., Schettini, F., Toppi, J., Risetti, M., Formisano, R., Molinari, M., Astolfi, L., Cincotti, F., & Mattia, D. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.018 · Cited by 37
Online Eye state recognition from EEG data using Deep architectures
Reddy, T. K., & Behera, L. (2016) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2016.7844325 · Cited by 36
Yang, D., Nguyen, T.-H., & Chung, W. (2020) · Sensors · doi:10.3390/s20195474 · Cited by 36
Marchetti, M., Piccione, F., Silvoni, S., Gamberini, L., & Priftis, K. (2013) · Neurorehabilitation and neural repair · doi:10.1177/1545968312471903 · Cited by 40
Pels, E. G. M., Aarnoutse, E. J., Ramsey, N. F., & Vansteensel, M. J. (2017) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968317714577 · Cited by 33
Performance optimization of ERP-based BCIs using dynamic stopping
Schreuder, M., Höhne, J., Treder, M., Blankertz, B., & Tangermann, M. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091134 · Cited by 34
Nathan, V., & Jafari, R. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2471080 · Cited by 34
Lopez, C. A. F., Li, G., & Zhang, D. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.611130 · Cited by 37
Brain-computer interfaces for people with amyotrophic lateral sclerosis
Vaughan, T. M. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00004-4 · Cited by 32
Self-citationA brain computer interface-based explorer
Bai, L., Yu, T., & Li, Y. (2014) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2014.06.015 · Cited by 33
Marchetti, M., & Priftis, K. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00012 · Cited by 33
Perruchoud, D., Pisotta, I., Carda, S., Murray, M. M., & Ionta, S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/041001 · Cited by 32
An ERP-based BCI with peripheral stimuli: validation with ALS patients
Miao, Y., Yin, E., Allison, B. Z., Zhang, Y., Chen, Y., Dong, Y., Wang, X., Hu, D., Chchocki, A., & Jin, J. (2019) · Cognitive Neurodynamics · doi:10.1007/s11571-019-09541-0 · Cited by 33
Exploration of the neural correlates of cerebral palsy for sensorimotor BCI control
Daly, I. P., Faller, J., Scherer, R., Sweeney‐Reed, C. M., Nasuto, S. J., Billinger, M., & Muller-Putz, G. R. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00020 · Cited by 31
Virtual Reality Cognitive Gaming Based on Brain Computer Interfacing: A Narrative Review
Hadjiaros, M., Neokleous, K., Shimi, A. G., Avraamides, M. N., & Pattichis, C. S. (2023) · IEEE Access · doi:10.1109/access.2023.3247133 · Cited by 33
Psychological Predictors of Visual and Auditory P300 Brain-Computer Interface Performance
Hammer, E. M., Halder, S., Kleih, S. C., & Kübler, A. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00307 · Cited by 33
A survey of brain computer interfaces and their applications
Major, T. C., & Conrad, J. M. (2014) · IEEE SoutheastCon · doi:10.1109/secon.2014.6950751 · Cited by 30
Spüler, M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7318554 · Cited by 30
Huggins, J. E., Guger, C., Ziat, M., Zander, T. O., Taylor, D., Tangermann, M., Soria‐Frisch, A., Simeral, J. D., Scherer, R., Rupp, R., et al. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2016.1275488 · Cited by 32
Blain‐Moraes, S., Chesser, S. A., Kingsnorth, S., McKeever, P. D., & Biddiss, E. A. (2013) · Augmentative and Alternative Communication · doi:10.3109/07434618.2012.760648 · Cited by 30
The effects of working memory on brain–computer interface performance
Sprague, S. A., McBee, M. T., & Sellers, E. W. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.10.038 · Cited by 31
Self-citationCritical Issues Using Brain-Computer Interfaces for Augmentative and Alternative Communication
Hill, K. J., Kovacs, T., & Shin, S. (2015) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2014.01.034 · Cited by 29
Neurotechnology ethics and relational agency
Goering, S., Brown, T., & Klein, E. P. (2021) · Philosophy Compass · doi:10.1111/phc3.12734 · Cited by 30
Endovascular Brain-Computer Interfaces in Poststroke Paralysis
Brannigan, J., Fry, A., Opie, N. L., Campbell, B. C. V., Mitchell, P. J., & Oxley, T. J. (2023) · Stroke · doi:10.1161/strokeaha.123.037719 · Cited by 32
Optimization of Single-Trial Detection of Event-Related Potentials Through Artificial Trials
Cecotti, H., Marathe, A. R., & Ries, A. J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2417054 · Cited by 28
A P300-based brain computer interface for smart home interaction through an ANFIS ensemble
Achanccaray, D., Flores, C., Fonseca, C., & Andreu-Pérez, J. (2017) · IEEE International Conference on Fuzzy Systems (FUZZ-IEEE) · doi:10.1109/fuzz-ieee.2017.8015770 · Cited by 28
McFarland, D. J., & Vaughan, T. M. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.06.005 · Cited by 28
Self-citationToward an Attention-Based Diagnostic Tool for Patients With Locked-in Syndrome
Lesenfants, D., Habbal, D., Chatelle, C., Soddu, A., Laureys, S., & Noirhomme, Q. (2016) · Clinical EEG and Neuroscience · doi:10.1177/1550059416674842 · Cited by 32
Utilizing a Language Model to Improve Online Dynamic Data Collection in P300 Spellers
Mainsah, B. O., Colwell, K. A., Collins, L. M., & Morton, K. D. (2014) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2014.2321290 · Cited by 27
Initial test of a T9-like P300-based speller by an ALS patient
Ron-Angevín, R., Varona-Moya, S., & da Silva‐Sauer, L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/4/046023 · Cited by 27
Evaluating the clinical benefit of brain-computer interfaces for control of a personal computer
Fry, A., Chan, A. H. W., Harel, N. Y., Spielman, L. A., Escalon, M. X., & Putrino, D. F. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac60ca · Cited by 27
Davis, K., Meschede-Krasa, B., Cajigas, I., Prins, N. W., Alver, C. G., Gallo, S., Bhatia, S., Abel, J. H., Naeem, J., Fisher, L., et al. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01026-2 · Cited by 31
Brain Signals for Brain–Computer Interfaces
Wolpaw, J. R., & Boulay, C. (2009) · The frontiers collection · doi:10.1007/978-3-642-02091-9_2 · Cited by 27
Self-citationSpeier, W. F., Fried, I., & Pouratian, N. (2013) · Clinical Neurophysiology · doi:10.1016/j.clinph.2013.02.002 · Cited by 28
Kuber, R., & Wright, F. P. (2013) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2012.702635 · Cited by 27
Tonin, A., Jaramillo-Gonzalez, A., Rana, A., Khalili‐Ardali, M., Birbaumer, N., & Chaudhary, U. (2020) · Scientific Reports · doi:10.1038/s41598-020-65333-1 · Cited by 29
Brain–Computer Interface Based Solutions for End-Users with Severe Communication Disorders
Kübler, A., & Mattia, D. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-800948-2.00014-5 · Cited by 28
Brain–computer interfaces for patients with disorders of consciousness
Gibson, R. M., Owen, A. M., & Cruse, D. (2016) · Progress in brain research · doi:10.1016/bs.pbr.2016.04.003 · Cited by 29
Mayaud, L., Cabanilles, S., van Langhenhove, A., Congedo, M., Barachant, A., Pouplin, S., Filipe, S., Pétégnief, L., Rochecouste, O., Azabou, É., et al. (2016) · Brain-Computer Interfaces · doi:10.1080/2326263x.2016.1254403 · Cited by 26
Metadata
- Authors
- Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R.
- Affiliations
- East Tennessee State University (US)
- New York State Department of Health (US)
- Corresponding author
- Sellers, Eric W.
- Venue
- Amyotrophic Lateral Sclerosis
- Publisher
- Informa UK Limited
- Published
- 2010-06-29
- Volume
- 11
- Issue
- 5
- Pages
- 449-455
- ISSN
- 1471-180X (ISSN-L)
- 1748-2968
- OpenAlex
- W1973921785
- Cited by
- 400
- References
- 30
- Citations by year
- 2026: 5 · 2025: 12 · 2024: 12 · 2023: 9 · 2022: 12 · 2021: 17 · 2020: 26 · 2019: 21 · 2018: 23 · 2017: 27 · 2016: 31 · 2015: 47 · 2014: 48 · 2013: 37 · 2012: 33
- FWCI
- 21.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Amyotrophic Lateral Sclerosis (publishedVersion)
- PubMed (publishedVersion)
- Digital Commons - East Tennessee State University (East Tennessee State University) (submittedVersion)
- Funders
- ALS Hope Foundation
- National Institute of Neurological Disorders and Stroke
- National Institute of Biomedical Imaging and Bioengineering (EB 00856, R01EB000856)
- Eunice Kennedy Shriver National Institute of Child Health and Human Development (R01HD030146, HD30146)
- National Center for Medical Rehabilitation Research
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Health Sciences › Health Professions › Occupational Therapy › Assistive Technology in Communication and Mobility
- Keywords
- brain-computer interface, severe motor impairment, EEG-based communication, assistive technology, caregiver education, quality of life
- MeSH terms
- Amyotrophic Lateral Sclerosis, Brain, Communication Devices for People with Disabilities, Electroencephalography, Persons with Disabilities, Humans, Male, Middle Aged, User-Computer Interface, Homebound Persons, Event-Related Potentials, P300
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review