The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Synthesis and characterization of PVP-functionalized superparamagnetic Fe3O4 nanoparticles as an MRI contrast agent
Open accessAbstract
The magnetite (Fe3O4) nanoparticles (MNPs) coated with poly(N-vinyl pyrrolidone) (PVP) via covalent bonds were prepared as T2 contrast agent for magnetic resonance imaging (MRI).The surface of MNPs was first coated with 3-(trimethoxysilyl) propyl methacrylate (silan A) by a silanization reaction to introduce reactive vinyl groups onto the surface, then poly(N-vinyl pyrrolidone) was grafted onto the surface of modified-MNPs via surface-initiated radical polymerization.The obtained nanoparticles were characterized by FT-IR (Fourier transform infrared spectroscopy), XRD (X-ray diffraction), TEM (transmission electron microscopy), VSM (vibrating sample magnetometer), and TGA (thermogravimetric analysis).The MNPs had an average size of 14 nm and exhibited superparamagnetism and high saturation magnetization at room temperature.T2-weighted MRI images of PVP-grafted MNPs showed that the magnetic resonance signal is enhanced significantly with increasing nanoparticle concentration in water.The r1 and r2 values per millimole Fe, and r2/r1 value of the PVP-grafted MNPs were calculated to be 2.6 , 72.1, and 28.1(mmol/l) -1 •s -1 , respectively.These results indicate that the PVP-grafted MNPs have great potential for application in MRI as a T2 contrast agent.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
Bean, C. P., & Livingston, J. D. (1959) · Journal of Applied Physics · doi:10.1063/1.2185850 · Cited by 1,773
Wang, Y.-X. J., Hussain, S. M., & Krestin, G. P. (2001) · European Radiology · doi:10.1007/s003300100908 · Cited by 1,381
Jung, C. W., & Jacobs, P. (1995) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)00024-b · Cited by 622
Lee, H., Lee, E., Kim, D. K., Jang, N. K., Jeong, Y. Y., & Jon, S. (2006) · Journal of the American Chemical Society · doi:10.1021/ja061529k · Cited by 594
Magnetic nanoparticles with dual functional properties: Drug delivery and magnetic resonance imaging
Jain, T. K., Richey, J., Strand, M., Leslie-Pelecky, D. L., Flask, C. A., & Labhasetwar, V. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.07.004 · Cited by 491
Kohler, N., Fryxell, G. E., & Zhang, M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja049195r · Cited by 466
Xu, C., Xu, K., Gu, H., Zhong, X., Guo, Z., Zheng, R., Zhang, X., & Xu, B. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031776d · Cited by 445
Kohler, N., Sun, C., Fichtenholtz, A., Gunn, J., Fang, C., & Zhang, M. (2006) · Small · doi:10.1002/smll.200600009 · Cited by 424
Gillis, P., & Koenig, S. H. (1987) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910050404 · Cited by 353
Contrast Agents for MR Imaging of the Liver
Semelka, R. C., & Helmberger, T. K. G. (2001) · Radiology · doi:10.1148/radiology.218.1.r01ja2427 · Cited by 337
Senéterre, E., Taourel, P., Bouvier, Y., Pradel, J., Van Beers, B., Daures, J. P., Pringot, J., Mathieu, D., & Bruel, J. M. (1996) · Radiology · doi:10.1148/radiology.200.3.8756932 · Cited by 310
Convection-enhanced delivery of nanocarriers for the treatment of brain tumors
Allard, E., Passirani, C., & Benoit, J.-P. (2009) · Biomaterials · doi:10.1016/j.biomaterials.2009.01.003 · Cited by 294
Cao, H., He, J., Deng, L., & Gao, X. (2009) · Applied Surface Science · doi:10.1016/j.apsusc.2009.04.199 · Cited by 270
Le Garrec, D., Gori, S., Luo, L., Lessard, D., Smith, D. C., Yessine, M.-A., Ranger, M., & Leroux, J.-C. (2004) · Journal of Controlled Release · doi:10.1016/j.jconrel.2004.06.018 · Cited by 255
Synthesis and Characterization of Soluble Iron Oxide−Dendrimer Composites
Strable, E., Bulte, J. W. M., Moskowitz, B., Vivekanandan, K., Allen, M., & Douglas, T. (2001) · Chemistry of Materials · doi:10.1021/cm010125i · Cited by 192
Magnetic Resonance of a Dextran-Coated Magnetic Fluid Intravenously Administered in Mice
Lacava, L. M., Lacava, Z. G. M., Da Silva, M. F., Silva, O., Chaves, S. B., Azevedo, R. B., Pelegrini, F., Gansau, C., Buske, N., Sabolovic, D., et al. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76217-0 · Cited by 172
Magnetite ferrofluid with high specific absorption rate for application in hyperthermia
Zhang, L.-Y., Gu, H.-C., & Wang, X.-M. (2007) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.11.179 · Cited by 165
Colloidal dispersions of monodisperse magnetite nanoparticles modified with poly(ethylene glycol)
Barrera, C., Herrera, A., & Rinaldi, C. (2008) · Journal of Colloid and Interface Science · doi:10.1016/j.jcis.2008.09.071 · Cited by 159
Fan, Q., Neoh, K. G., Kang, E. T., Shuter, B., & Wang, S. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.08.039 · Cited by 152
Specific MR imaging of human lymphocytes by monoclonal antibody‐guided dextran‐magnetite particles
Bulte, J. W. M., Hoekstra, Y., Kamman, R. L., Magin, R. L., WEBB, A. G., Briggs, R. W., Go, K. G., Hulstaert, C. E., Miltenyi, S., THE, T. H., et al. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250115 · Cited by 147
Lee, H., Lee, S., Xu, C., Xie, J., Lee, J., Wu, B., Koh, A. L., Wang, X., Sinclair, R., Wang, S. X., et al. (2008) · Nanotechnology · doi:10.1088/0957-4484/19/16/165101 · Cited by 144
Liu, H.-L., Ko, S. P., Wu, J.-H., Jung, M., Min, J. H., Lee, J. H., An, B. H., & Kim, Y. K. (2006) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2006.10.776 · Cited by 129
Novel nanomedicine-based MRI contrast agents for gynecological malignancies
Mody, V. V., Nounou, M. I., & Bikram, M. (2009) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2009.04.020 · Cited by 128
Preparation and application of polymer-grafted magnetic nanoparticles for lipase immobilization
Yong, Y., Bai, Y., Li, Y., Lei, L., Cui, Y., & Xia, C. (2008) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2008.04.158 · Cited by 127
Brusentsov, N. A., Гогосов, В. В., Brusentsova, T. N., et al. (2001) · Journal of Magnetism and Magnetic Materials · doi:10.1016/s0304-8853(00)01238-5 · Cited by 116
Kaim, A. H., Wischer, T. K., O’Reilly, T., Jundt, G., Froehlich, J. M., von Schulthess, G. K., & ALLEGRINI, P. R. (2002) · Radiology · doi:10.1148/radiol.2253011485 · Cited by 73
Tietze, R., Jurgons, R., Lyer, S., Schreiber, E., Wiekhorst, F., Eberbeck, D., Richter, H., Steinhoff, U., Trahms, L., & Alexiou, C. (2009) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2009.02.068 · Cited by 47
Liu, J. W., Zhang, Y., Chen, D., Yang, T., Chen, Z. P., Pan, S. Y., & Gu, N. (2009) · Colloids and Surfaces A Physicochemical and Engineering Aspects · doi:10.1016/j.colsurfa.2009.03.033 · Cited by 26
Relaxometry of magnetic resonance imaging contrast agents.
Koenig, S. H., & Rd, B. (1987) · PubMed · Cited by 16
Cited by
Nanoparticles in biomedical applications
McNamara, K., & Tofail, S. A. M. (2017) · Advances in Physics: X · doi:10.1080/23746149.2016.1254570 · Cited by 529
Metadata
- Authors
- Arsalani, N., Fattahi, H., & Nazarpoor, M.
- Venue
- Express Polymer Letters
- Published
- 2010
- Volume
- 4
- Issue
- 6
- Pages
- 329-338
- ISSN
- 1788-618X (ISSN-L)
- OpenAlex
- W2060029924
- Cited by
- 259
- References
- 30
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- diamond
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.