Near-infrared spectroscopic localization of intracranial hematomas
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
✓ Near-infrared spectroscopy (NIRS) of the cerebral hemispheres, applied transcranially through the intact scalp and skull, was evaluated for its ability to detect the presence of an intracranial hematoma in 46 head-injured patients. In 40 patients intracranial hematomas (22 subdural, 10 epidural, eight intracerebral) were identified on computerized tomography (CT); in all 40 cases, NIRS demonstrated greater absorption of light at 760 nm on the side of the hematoma. The mean difference in optical density (OD) between the hemisphere with the hematoma and the normal hemisphere was 0.99 ± 0.30 for epidural hematomas, 0.87 ± 0.31 for subdural hematomas, but only 0.41 ± 0.11 for intracerebral hematomas. In 36 patients, the asymmetry in OD resolved after surgical evacuation of the hematoma or with spontaneous resorption of the hematoma. Four patients who developed postoperative or delayed hematomas exhibited persistence of the asymmetry in OD. Six patients had only diffuse injuries and exhibited only minor differences in OD between the hemispheres, similar to 10 patients in the control group with no head injury. It appears that NIRS is useful in the initial examination of the head-injured patient, as an adjunct to CT, and in following patients postoperatively in the intensive care unit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Wray, S., Cope, M., Delpy, D. T., Wyatt, J. S., & Reynolds, E. O. R. (1988) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/0005-2728(88)90069-2 · Cited by 912
Wyatt, J. S., Delpy, D. T., Cope, M., Wray, S., & Reynolds, E. O. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90467-8 · Cited by 876
Impaired autoregulation of cerebral blood flow in the distressed newborn infant
Lou, H. C., Lassen, N. A., & Friis-Hansen, B. (1979) · The Journal of Pediatrics · doi:10.1016/s0022-3476(79)80373-x · Cited by 642
Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain.
Chance, B., Leigh, J. S., Miyake, H., Smith, D. S., Nioka, S., Greenfeld, R., Finander, M., Kaufmann, K., Levy, W., & Young, M. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.14.4971 · Cited by 464
Self-citationCOTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370
Noninvasive Monitoring of Cerebral Oxygenation in Preterm Infants: Preliminary Observations
Brazy, J. E., Lewis, D. V., Mitnick, M. H., & vander Vliet, F. F. J. (1985) · Pediatrics · doi:10.1542/peds.75.2.217 · Cited by 356
Hazeki, O., & Tamura, M. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.64.2.796 · Cited by 129
Changes in cerebral blood volume and cytochrome aa3 during hypertensive peaks in preterm infants
Brazy, J. E., & Lewis, D. V. (1986) · The Journal of Pediatrics · doi:10.1016/s0022-3476(86)80944-1 · Cited by 102
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Spectroscopy and Imaging with Diffusing Light
Yodh, A., & Chance, B. (1995) · Physics Today · doi:10.1063/1.881445 · Cited by 800
Self-citationConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationBoas, D. A., & Yodh, A. G. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000192 · Cited by 606
Fluorescence Spectroscopy In Vivo
Ramanujam, N. (2000) · Encyclopedia of Analytical Chemistry · doi:10.1002/9780470027318.a0102 · Cited by 508
Okada, E., Firbank, M., Schweiger, M., Arridge, S. R., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000021 · Cited by 477
Irani, F., Platek, S. M., Bunce, S., Ruocco, A. C., & Chute, D. (2007) · The Clinical Neuropsychologist · doi:10.1080/13854040600910018 · Cited by 451
Hielscher, A. H., Alcouffe, R. E., & Barbour, R. L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/5/017 · Cited by 332
Near-infrared oximetry of the brain
Madsen, P. L., & Secher, N. H. (1999) · Progress in Neurobiology · doi:10.1016/s0301-0082(98)00093-8 · Cited by 315
Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/6/308 · Cited by 277
“…Edwards et al 1988) and in adults to quantify cerebral hemodynamics (Elwell et al 1994), to monitor brain activity (Gratton et al 1995, Meek et al 1995, Wenzel et al 1996, Tamura et al 1997, Villringer and Chance 1997) and to detect intracranial haematomas (Gopinath et al 1993, Hennes et al 1999).”
On-line optical imaging of the human brain with 160-ms temporal resolution
Franceschini, M. A., Toronov, V., Filiaci, M. E., Gratton, E., & Fantini, S. (2000) · Optics Express · doi:10.1364/oe.6.000049 · Cited by 237
Zauner, A., Doppenberg, E. M. R., Woodward, J. J., Choi, S. C., Young, H. F., & Bullock, R. (1997) · Neurosurgery · doi:10.1097/00006123-199711000-00011 · Cited by 218
Wilson, M., Davis, D. P., & Coimbra, R. (2003) · The Journal of Emergency Medicine · doi:10.1016/s0736-4679(03)00042-8 · Cited by 176
Franceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Near-infrared spectroscopy use in patients with head injury
Kirkpatrick, P. J., Smielewski, P., Czosnyka, M., Menon, D. K., & Pickard, J. D. (1995) · Journal of Neurosurgery · doi:10.3171/jns.1995.83.6.0963 · Cited by 162
Near‐Infrared Diffuse Optical Tomography
Hielscher, A. H., Bluestone, A. Y., Abdoulaev, G. S., Klose, A. D., Lasker, J., Stewart, M., Netz, U., & Beuthan, J. (2002) · Disease Markers · doi:10.1155/2002/164252 · Cited by 159
“methods [81,147].”
Background
Metadata
- Authors
- Gopinath, S. P., Robertson, C. S., Grossman, R. G., & Chance, B.
- Venue
- Journal of Neurosurgery
- Published
- 1993-07
- Volume
- 79
- Issue
- 1
- Pages
- 43-47
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2085624360
- Cited by
- 163
- References
- 14
- FWCI
- 8.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.