Thalamic stimulation and functional magnetic resonance imaging: localization of cortical and subcortical activation with implanted electrodes: Technical note
The DOI matches its Crossref record.
Abstract
✓ The utility of functional magnetic resonance (fMR) imaging in patients with implanted thalamic electrodes has not yet been determined. The aim of this study was to establish the safety of performing fMR imaging in patients with thalamic deep brain stimulators and to determine the value of fMR imaging in detecting cortical and subcortical activity during stimulation. Functional MR imaging was performed in three patients suffering from chronic pain and two patients with essential tremor. Two of the three patients with pain had undergone electrode implantation in the thalamic sensory ventralis caudalis (Vc) nucleus and the other had undergone electrode implantation in both the Vc and the periventricular gray (PVG) matter. Patients with tremor underwent electrode implantation in the ventralis intermedius (Vim) nucleus. Functional MR imaging was performed during stimulation by using a pulse generator connected to a transcutaneous extension lead. Clinically, Vc stimulation evoked paresthesias in the contralateral body, PVG stimulation evoked a sensation of diffuse internal body warmth, and Vim stimulation caused tremor arrest. Functional images were acquired using a 1.5-tesla MR imaging system. The Vc stimulation at intensities provoking paresthesias resulted in activation of the primary somatosensory cortex (SI). Stimulation at subthreshold intensities failed to activate the SI. Additional stimulation-coupled activation was observed in the thalamus, the secondary somatosensory cortex (SII), and the insula. In contrast, stimulation of the PVG electrode did not evoke paresthesias or activate the SI, but resulted in medial thalamic and cingulate cortex activation. Stimulation in the Vim resulted in thalamic, basal ganglia, and SI activation. An evaluation of the safety of the procedure indicated that significant current could be induced within the electrode if a faulty connecting cable (defective insulation) came in contact with the patient. Simple precautions, such as inspection of wires for fraying and prevention of their contact with the patient, enabled the procedure to be conducted safely. Clinical safety was further corroborated by performing 86 MR studies in patients in whom electrodes had been implanted with no adverse clinical effects. This is the first report of the use of fMR imaging during stimulation with implanted thalamic electrodes. The authors' findings demonstrate that fMR imaging can safely detect the activation of cortical and subcortical neuronal pathways during stimulation and that stimulation does not interfere with imaging. This approach offers great potential for understanding the mechanisms of action of deep brain stimulation and those underlying pain and tremor generation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Perlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073
Translational principles of deep brain stimulation
Kringelbach, M. L., Jenkinson, N., Owen, S. L. F., & Aziz, T. Z. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2196 · Cited by 853
Uncovering the mechanism(s) of action of deep brain stimulation: activation, inhibition, or both
McIntyre, C. C., Savasta, M., Kerkerian-Le Goff, L., & Vitek, J. L. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.12.024 · Cited by 741
MR Procedures: Biologic Effects, Safety, and Patient Care
Shellock, F. G., & Crues, J. V. (2004) · Radiology · doi:10.1148/radiol.2323030830 · Cited by 563
Network perspectives on the mechanisms of deep brain stimulation
McIntyre, C. C., & Hahn, P. J. (2010) · Neurobiology of Disease · doi:10.1016/j.nbd.2009.09.022 · Cited by 439
Starr, P. A., Christine, C. W., Theodosopoulos, P. V., Lindsey, N., Byrd, D., Mosley, A., & Marks, W. J. (2002) · Journal of Neurosurgery · doi:10.3171/jns.2002.97.2.0370 · Cited by 415
Long-term Hardware-related Complications of Deep Brain Stimulation
Oh, M. Y., Abosch, A., Kim, S. H., Lang, A. E., & Lozano, A. M. (2002) · Neurosurgery · doi:10.1097/00006123-200206000-00017 · Cited by 405
Self-citationDeep brain stimulation for pain relief: A meta-analysis
Bittar, R. G., Kar-Purkayastha, I., Owen, S. L., Bear, R. E., Green, A., Wang, S., & Aziz, T. Z. (2005) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2004.10.005 · Cited by 396
Deep brain stimulation for Parkinson's disease: disrupting the disruption
Lozano, A. M., Dostrovsky, J., Chen, R., & Ashby, P. (2002) · The Lancet Neurology · doi:10.1016/s1474-4422(02)00101-1 · Cited by 354
Self-citationTechnical aspects and utility of fMRI using BOLD and ASL
Detre, J. A., & Wang, J. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00038-x · Cited by 291
Rezai, A. R., Finelli, D., Nyenhuis, J. A., Hrdlicka, G., Tkach, J., Sharan, A., Rugieri, P., Stypulkowski, P. H., & Shellock, F. G. (2002) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10069 · Cited by 285
Self-citationRauch, S. L., Dougherty, D. D., Malone, D., Rezai, A., Friehs, G., Fischman, A. J., Alpert, N. M., Haber, S. N., Stypulkowski, P. H., Rise, M. T., et al. (2006) · Journal of Neurosurgery · doi:10.3171/jns.2006.104.4.558 · Cited by 260
Self-citationMure, H., Hirano, S., Tang, C. C., Isaias, I. U., Antonini, A., Ma, Y., Dhawan, V., & Eidelberg, D. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.09.028 · Cited by 259
Stefurak, T., Mikulis, D., Mayberg, H., Lang, A. E., Hevenor, S., Pahapill, P., Saint‐Cyr, J., & Lozano, A. (2003) · Movement Disorders · doi:10.1002/mds.10593 · Cited by 215
Self-citationRezai, A. R., Phillips, M., Baker, K. B., Sharan, A. D., Nyenhuis, J., Tkach, J., Henderson, J., & Shellock, F. G. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000124940.02340.ab · Cited by 192
Self-citationBlood flow responses to deep brain stimulation of thalamus
Perlmutter, J. S., Mink, J. W., Bastian, A. J., Zackowski, K., Hershey, T., Miyawaki, E., Koller, W., & Videen, T. O. (2002) · Neurology · doi:10.1212/wnl.58.9.1388 · Cited by 175
Jech, R., Urgošík, D., Tintěra, J., Nebuželský, A., Krásenský, J., Liščák, R., Roth, J., & Růžička, E. (2001) · Movement Disorders · doi:10.1002/mds.1217 · Cited by 172
Grachev, I. D., Thomas, P. S., & Ramachandran, T. S. (2002) · Brain and Cognition · doi:10.1006/brcg.2001.1489 · Cited by 58
Metadata
- Authors
- Rezai, A. R., Lozano, A. M., Crawley, A. P., Joy, M. L. G., Davis, K. D., Kwan, C. L., Dostrovsky, J. O., Tasker, R. R., & Mikulis, D. J.
- Venue
- Journal of Neurosurgery
- Published
- 1999-03
- Volume
- 90
- Issue
- 3
- Pages
- 583-590
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2164007320
- Cited by
- 169
- References
- 0
- FWCI
- 6.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.