Five-year experience in using coil embolization for ruptured intracranial aneurysms: outcomes and incidence of late rebleeding
Abstract
Object. During a 5-year period 317 patients presenting with aneurysmal subarachnoid hemorrhage were successfully treated by coil embolization within 30 days of hemorrhage. The authors followed patients to assess the stability of aneurysm occlusion and its longer-term efficacy in protecting patients against rebleeding. Methods. Patients were followed for 6 to 65 months (median 22.3 months) by clinical review, angiography performed at 6 months posttreatment, and annual questionnaires. Stable angiographic occlusion was evident in 86.4% of small and 85.2% of large aneurysms with recurrent filling in 38 (14.7%) of 259 aneurysms. Rebleeding was caused by aneurysm recurrence in four patients (between 11 and 35 months posttreatment) and by rupture of a coincidental untreated aneurysm in one patient. Annual rebleeding rates were 0.8% in the 1st year, 0.6% in the 2nd year, and 2.4% in the 3rd year after aneurysm embolization, with no rebleeding in subsequent years. Rebleeding occurred in three (7.9%) of 38 recurrent aneurysms and in one (0.4%) of 221 aneurysms that appeared stable on angiography. Conclusions. Periodic follow-up angiography after coil embolization is recommended to identify aneurysm recurrence and those patients at a high risk of late rebleeding.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ASSESSMENT OF OUTCOME AFTER SEVERE BRAIN DAMAGE A Practical Scale
JENNETT, B. (1975) · The Lancet · doi:10.1016/s0140-6736(75)92830-5 · Cited by 7,501
Kassell, N. F., Torner, J. C., Haley, E. C., Jane, J. A., Adams, H. P., Kongable, G. L., & _, _. (1990) · Journal of Neurosurgery · doi:10.3171/jns.1990.73.1.0018 · Cited by 2,112
Guglielmi, G., Viñuela, F., Dion, J., & Duckwiler, G. (1991) · Journal of Neurosurgery · doi:10.3171/jns.1991.75.1.0008 · Cited by 1,364
(1988) · Journal of Neurosurgery · doi:10.3171/jns.1988.68.6.0985 · Cited by 1,196
Viñuela, F., Duckwiler, G., & Mawad, M. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.86.3.0475 · Cited by 875
Guglielmi, G., Viñuela, F., Duckwiler, G., Dion, J., Lylyk, P., Berenstein, A., Strother, C., Graves, V., Halbach, V., Nichols, D., et al. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.77.4.0515 · Cited by 645
Fernández‐Zubillaga, A., Guglielmi, G., Viñuela, F., & Duckwiler, G. (1994) · PubMed Central · Cited by 530
Regrowth of aneurysm sacs from residual neck following aneurysm clipping
Lin, T. S., Fox, A. J., & Drake, C. G. (1989) · Journal of neurosurgery · doi:10.3171/jns.1989.70.4.0556 · Cited by 319
Intracranial berry aneurysms: angiographic and clinical results after endovascular treatment.
Cognard, C., Weill, A., Castaings, L., Rey, A., & Moret, J. (1998) · Radiology · doi:10.1148/radiology.206.2.9457205 · Cited by 296
Haley, E. C., Kassell, N. F., Apperson-Hansen, C., Maile, M. H., Alves, W. M., & _, _. (1997) · Journal of Neurosurgery · doi:10.3171/jns.1997.86.3.0467 · Cited by 294
Role of angiography following aneurysm surgery
Macdonald, R. L., Wallace, M. C., & Kestle, J. R. W. (1993) · Journal of neurosurgery · doi:10.3171/jns.1993.79.6.0826 · Cited by 255
Selective endovascular treatment of 71 intracranial aneurysms with platinum coils
Casasco, A. E., Aymard, A., Gobin, Y. P., Houdart, E., Rogopoulos, A., George, B., Hodes, J. E., Cophignon, J., & Merland, J. J. (1993) · Journal of Neurosurgery · doi:10.3171/jns.1993.79.1.0003 · Cited by 233
Säveland, H., Hillman, J., Brandt, L., Edner, G., Jakobsson, K.-E., & Algers, G. (1992) · Journal of Neurosurgery · doi:10.3171/jns.1992.76.5.0729 · Cited by 191
Can Simple Questions Assess Outcome after Stroke?
Lindley, R. I., Waddell, F., Livingstone, M., Sandercock, P. A., Dennis, M. S., Slattery, J., Smith, B., & Warlow, C. P. (1994) · Cerebrovascular Diseases · doi:10.1159/000108501 · Cited by 132
Recurrence of ICA-PCoA aneurysms after neck clipping
Sakaki, T., TAKESHIMA, T., Tominaga, M., Hashimoto, H., & Kawaguchi, S. (1994) · Journal of neurosurgery · doi:10.3171/jns.1994.80.1.0058 · Cited by 102
The nature of thrombosis induced by platinum and tungsten coils in saccular aneurysms.
Byrne, J. V., Hope, J. K. A., Hubbard, N., & Morris, J. H. (1997) · PubMed · Cited by 91
Self-citation
Cited by
Molyneux, A. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11314-6 · Cited by 3,626
Self-citationRaymond, J., Guilbert, F., Weill, A., Georganos, S. A., Juravsky, L., Lambert, A., Lamoureux, J., Chagnon, M., & Roy, D. (2003) · Stroke · doi:10.1161/01.str.0000073841.88563.e9 · Cited by 1,496
Subarachnoid haemorrhage: diagnosis, causes and management
van Gijn, J., & Rinkel, G. J. E. (2001) · Brain · doi:10.1093/brain/124.2.249 · Cited by 1,353
Guglielmi Detachable Coil embolization of cerebral aneurysms: 11 years' experience
Murayama, Y., Nien, Y. L., Duckwiler, G., Gobin, Y. P., Jahan, R., Frazee, J., Martin, N., & Viñuela, F. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.5.0959 · Cited by 810
Campi, A., Ramzi, N., Molyneux, A. J., Summers, P. E., Kerr, R. S. C., Sneade, M., Yarnold, J. A., Rischmiller, J., & Byrne, J. V. (2007) · Stroke · doi:10.1161/strokeaha.106.466987 · Cited by 553
Self-citation
Metadata
- Authors
- Byrne, J. V., Sohn, M.-J., & Molyneux, A. J.
- Venue
- Journal of Neurosurgery
- Published
- 1999-04
- Volume
- 90
- Issue
- 4
- Pages
- 656-663
- ISSN
- 0022-3085 (ISSN-L)
- OpenAlex
- W2165852737
- Cited by
- 485
- References
- 16
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.