Long-Term Follow-Up of Cerebral Aneurysms after Endovascular Therapy Prediction and Outcome of Retreatment
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
BACKGROUND AND PURPOSE: The purpose of this study was to analyze angiographic and clinical results before and after additional endovascular therapy in patients with previously coiled but reopened cerebral aneurysms and to identify possible risk factors for retreatment of an aneurysm. MATERIALS AND METHODS: Follow-up with selective digital subtraction angiography was performed in 323/596 (54.2%) patients harboring 342 aneurysms with a mean follow-up time of 28.6 months. The patients were divided into 3 groups: group A, who remained stable after initial treatment; group B, who showed minor morphologic changes; and group C, who underwent repeat treatment. Univariate and multivariate regression analyses were performed to determine possible risk factors for aneurysmal retreatment. RESULTS: Single or multiple retreatment was performed in 33 of 323 (10.2%) patients. Retreatment of small aneurysms (< or =10 mm) with small necks (< or =4 mm) was performed in 6 of 214 aneurysms. When summarizing all other aneurysms as a "risk group" (n = 128), the odds ratio (OR) for retreatment in the "risk group" was 3.11 (95% CI: 1.43-6.75; P = .004). In patients with residual aneurysm after the first treatment, OR for retreatment was 3.96 (95% CI: 1.48-10.65; P = .006), whereas a neck remnant, clinical presentation, and aneurysmal localization were not predictive. We observed no resulting morbidity and mortality from the 33 retreatment procedures. CONCLUSION: In our series, the retreatment of aneurysmal recurrences was a safe procedure. The best single predictors of aneurysmal recurrence were aneurysmal anatomy (neck width >4 mm and diameter >10 mm) and the presence of a residual aneurysm after initial treatment. A limitation in our study was the significant number of patients lost to follow-up (22.7%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Molyneux, A. (2002) · The Lancet · doi:10.1016/s0140-6736(02)11314-6 · Cited by 3,626 · cited 1×
“Endovascular coil embolization of cerebral aneurysms is associated with low morbidity and mortality rates and has become widely used in patients with ruptured and unruptured intracranial aneurysms.(1-8) Recent data on the incidence of rebleeding after endovascular aneurysm therapy indicate that the rate is as low as 0.”
BackgroundMolyneux, A. J., Kerr, R. S., Yu, L.-M., Clarke, M., Sneade, M., Yarnold, J. A., & Sandercock, P. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67214-5 · Cited by 2,886
Raymond, J., Guilbert, F., Weill, A., Georganos, S. A., Juravsky, L., Lambert, A., Lamoureux, J., Chagnon, M., & Roy, D. (2003) · Stroke · doi:10.1161/01.str.0000073841.88563.e9 · Cited by 1,496 · cited 4×
“Similar experiences were reported by Raymond et al.(14)”
BackgroundResultInfluentialEndovascular Treatment of Unruptured Aneurysms
Roy, D., Milot, G., & Raymond, J. (2001) · Stroke · doi:10.1161/hs0901.095600 · Cited by 961 · cited 2×
“tained to assess the result according to the classification as proposed by Roy et al.(24) Embolization was considered to be complete (c/o) if”
MethodGuglielmi Detachable Coil embolization of cerebral aneurysms: 11 years' experience
Murayama, Y., Nien, Y. L., Duckwiler, G., Gobin, Y. P., Jahan, R., Frazee, J., Martin, N., & Viñuela, F. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.5.0959 · Cited by 810 · cited 1×
“Endovascular coil embolization of cerebral aneurysms is associated with low morbidity and mortality rates and has become widely used in patients with ruptured and unruptured intracranial aneurysms.(1-8) Recent data on the incidence of rebleeding after endovascular aneurysm therapy indicate that the rate is as low as 0.”
BackgroundAmerican Journal of Neuroradiology
Lee, S. (1986) · Surgical Neurology · doi:10.1016/0090-3019(86)90301-0 · Cited by 556
Byrne, J. V., Sohn, M.-J., & Molyneux, A. J. (1999) · Journal of Neurosurgery · doi:10.3171/jns.1999.90.4.0656 · Cited by 485
Long-term Angiographic Follow-up of 169 Intracranial Berry Aneurysms Occluded with Detachable Coils
Cognard, C., Weill, A., Spelle, L., Piotin, M., Castaings, L., Rey, A., & Moret, J. (1999) · Radiology · doi:10.1148/radiology.212.2.r99jl47348 · Cited by 413
Endovascular Coil Occlusion of 1811 Intracranial Aneurysms: Early Angiographic and Clinical Results
Henkes, H., Fischer, S., Weber, W., Miloslavski, E., Felber, S., Brew, S., & Kuehne, D. (2004) · Neurosurgery · doi:10.1227/01.neu.0000103221.16671.f0 · Cited by 322
Regrowth of aneurysm sacs from residual neck following aneurysm clipping
Lin, T. S., Fox, A. J., & Drake, C. G. (1989) · Journal of neurosurgery · doi:10.3171/jns.1989.70.4.0556 · Cited by 319 · cited 1×
“However, the risk of bleeding in these small recurrences cannot be ruled out completely.(26) Location of the aneurysm was no significant predictor of recurrent treatment.”
BackgroundThe CARAT Investigators* (2006) · Stroke · doi:10.1161/01.str.0000221331.01830.ce · Cited by 306 · cited 1×
“a.(5,9,10) A major concern of endovascular treatment is the possibility of reopening of a coiled aneurysm and the necessity of a retreatment with its inherent risks and costs.”
BackgroundMurayama, Y., Tateshima, S., Gonzalez, N. R., & Vinuela, F. (2003) · Stroke · doi:10.1161/01.str.0000083394.33633.c2 · Cited by 228 · cited 1×
“The first clinical observations of these devices, however, reveal variable results.(18-23) We present the data of our institutional review on both the stability of endovascular treatment in patients with aneurysm and the rate, morbidity, and mortality of the retreatment procedures.”
BackgroundA multicenter study of 705 ruptured intracranial aneurysms treated with Guglielmi detachable coils.
Gallas, S., Pasco, A., Cottier, J., Gabrillargues, J., Drouineau, J., Cognard, C., & Herbreteau, D. (2005) · PubMed Central · Cited by 217
Thornton, J., Debrun, G. M., Aletich, V. A., Bashir, Q., Charbel, F. T., & Ausman, J. (2002) · Neurosurgery · doi:10.1097/00006123-200202000-00003 · Cited by 196
Sluzewski, M., van Rooij, W. J., Rinkel, G. J. E., & Wijnalda, D. (2003) · Radiology · doi:10.1148/radiol.2273020656 · Cited by 193 · cited 1×
“A major concern of endovascular treatment is the possibility of reopening of a coiled aneurysm and the necessity of a retreatment with its inherent risks and costs.(11-13) Nevertheless, since the estimates for aneurysm recurrence can be expected in a range from 6.”
BackgroundPark, H. K., Horowitz, M., Jungreis, C. A., Genevro, J., Koebbe, C. J., Levy, E. I., & Kassam, A. B. (2005) · PubMed Central · Cited by 186
Friedman, J. A., Nichols, D. A., Meyer, F. B., Pichelmann, M. A., McIver, J. I., Toussaint, L. G., Axley, P. L., & Brown, R. D. (2003) · PubMed · Cited by 140
Henkes, H. H., Fischer, S., Liebig, T., Weber, W., Reinartz, J., Miloslavski, E., & Kühne, D. (2006) · Neurosurgery · doi:10.1227/01.neu.0000194831.54183.3f · Cited by 133
Embolization of Intracranial Aneurysms With Hydrogel-Coated Coils Versus Inert Platinum Coils
Gaba, R. C., Ansari, S. A., Roy, S. S., Marden, F. A., Viana, M. A. G., & Malisch, T. W. (2006) · Stroke · doi:10.1161/01.str.0000221314.55144.0b · Cited by 125
Durability of Aneurysm Embolization with Matrix Detachable Coils
Fiorella, D. J., Albuquerque, F. C., & McDougall, C. G. (2005) · Neurosurgery · doi:10.1227/01.neu.0000194190.45595.9e · Cited by 124
Additional coiling of previously coiled cerebral aneurysms: clinical and angiographic results.
Slob, M. J., Sluzewski, M., van Rooij, W. J., Roks, G., & Rinkel, G. J. E. (2004) · PubMed Central · Cited by 101
Mallouhi, A., Felber, S. R., Chemelli, A., Dessl, A., Auer, A., Schocke, M., Jaschke, W. R., & Waldenberger, P. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.1.1800055 · Cited by 68 · cited 2×
“Even if rebleeding from completely occluded aneurysms on angiograms has been reported,5 a further impetus for control angiograms is the detection of treatable aneurysmal recurrences, which are thought to be a risk factor for SAH, perhaps more often with noninvasive techniques such as MRA.30,31 A single retreatment of…”
BackgroundInfluentialMurayama, Y., Suzuki, Y., Viñuela, F., Kaibara, M., Kurotobi, K., Iwaki, M., & Abe, T. (1999) · PubMed Central · Cited by 49
Cited by
Ferns, S. P., Sprengers, M. E. S., van Rooij, W. J., Rinkel, G. J. E., van Rijn, J. C., Bipat, S., Sluzewski, M., & Majoie, C. B. L. M. (2009) · Stroke · doi:10.1161/strokeaha.109.553099 · Cited by 455
Metadata
- Authors
- Ries, T., Siemonsen, S., Thomalla, G., Grzyska, U., Zeumer, H., & Fiehler, J.
- Venue
- American Journal of Neuroradiology
- Published
- 2007-10-01
- Volume
- 28
- Issue
- 9
- Pages
- 1755-1761
- ISSN
- 0195-6108 (ISSN-L)
- 1936-959X
- OpenAlex
- W2031345969
- Cited by
- 186
- References
- 23
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.