The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Gadolinium-Based Contrast Agent Accumulation and Toxicity: An Update
Open accessAbstract
In current practice, gadolinium-based contrast agents have been considered safe when used at clinically recommended doses in patients without severe renal insufficiency. The causal relationship between gadolinium-based contrast agents and nephrogenic systemic fibrosis in patients with renal insufficiency resulted in new policies regarding the administration of these agents. After an effective screening of patients with renal disease by performing either unenhanced or reduced-dose-enhanced studies in these patients and by using the most stable contrast agents, nephrogenic systemic fibrosis has been largely eliminated since 2009. Evidence of in vivo gadolinium deposition in bone tissue in patients with normal renal function is well-established, but recent literature showing that gadolinium might also deposit in the brain in patients with intact blood-brain barriers caught many individuals in the imaging community by surprise. The purpose of this review was to summarize the literature on gadolinium-based contrast agents, tying together information on agent stability and animal and human studies, and to emphasize that low-stability agents are the ones most often associated with brain deposition.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
American Journal of Neuroradiology
(2020) · American Journal of Neuroradiology · doi:10.3174/ajnr · Cited by 2,453
Grobner, T. (2006) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfk062 · Cited by 1,859
Marckmann, P., Skov, L., Rossen, K., Dupont, A., Damholt, M. B., Heaf, J. G., & Thomsen, H. S. (2006) · Journal of the American Society of Nephrology · doi:10.1681/asn.2006060601 · Cited by 1,400
Intracranial gadolinium deposition after contrast-enhanced MR imaging
McDonald, R. J., McDonald, J. S., Kallmes, D. F., Jentoft, M. E., Murray, D. L., Thielen, K. R., Williamson, E. E., & Eckel, L. J. (2015) · Radiology · doi:10.1148/radiol.15150025 · Cited by 1,358
Kanda, T., Ishii, K., Kawaguchi, H., Kitajima, K., & Takenaka, D. (2014) · Radiology · doi:10.1148/radiol.13131669 · Cited by 1,339
Kanda, T., Fukusato, T., Matsuda, M., Toyoda, K., Oba, H., Kotoku, J., Haruyama, T., Kitajima, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.2015142690 · Cited by 874
Radbruch, A., Weberling, L. D., Kieslich, P. J., Eidel, O., Burth, S., Kickingereder, P., Heiland, S., Wick, W., Schlemmer, H.-P., & Bendszus, M. (2015) · Radiology · doi:10.1148/radiol.2015150337 · Cited by 561
Stability of Gadolinium-Based Magnetic Resonance Imaging Contrast Agents in Human Serum at 37°C
Frenzel, T., Lengsfeld, P., Schirmer, H., Hütter, J., & Weinmann, H.-J. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181852171 · Cited by 539
Biodistribution of gadolinium‐based contrast agents, including gadolinium deposition
Aime, S., & Caravan, P. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21969 · Cited by 534
Kanda, T., Osawa, M., Oba, H., Toyoda, K., Kotoku, J., Haruyama, T., Takeshita, K., & Furui, S. (2015) · Radiology · doi:10.1148/radiol.14140364 · Cited by 472
Errante, Y., Cirimele, V., Mallio, C. A., Di Lazzaro, V., Zobel, B. B., & Quattrocchi, C. C. (2014) · Investigative Radiology · doi:10.1097/rli.0000000000000072 · Cited by 421
White, G. W., Gibby, W. A., & Tweedle, M. F. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000186569.32408.95 · Cited by 362
MRI contrast agents: Basic chemistry and safety
Hao, D., Ai, T., Goerner, F., Hu, X., Runge, V. M., & Tweedle, M. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23725 · Cited by 336
Incorporation of excess gadolinium into human bone from medical contrast agents
Darrah, T. H., Prutsman-Pfeiffer, J. J., Poreda, R. J., Ellen Campbell, M., Hauschka, P. V., & Hannigan, R. E. (2009) · Metallomics · doi:10.1039/b905145g · Cited by 299
Ersoy, H., & Rybicki, F. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21135 · Cited by 283
Broome, D. R. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.02.011 · Cited by 283
Toxicological and cytophysiological aspects of lanthanides action.
Pałasz, A., & Czekaj, P. (2000) · Acta Biochimica Polonica · doi:10.18388/abp.2000_3963 · Cited by 268
MR contrast agents: Physical and pharmacologic basics
Lin, S., & Brown, J. J. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20955 · Cited by 259
Robert, P., Lehericy, S., Grand, S., Violas, X., Fretellier, N., Idée, J.-M., Ballet, S., & Corot, C. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000181 · Cited by 257
Ramalho, J., Castillo, M., AlObaidy, M., Nunes, R. H., Ramalho, M., Dale, B. M., & Semelka, R. C. (2015) · Radiology · doi:10.1148/radiol.2015150872 · Cited by 230
Self-citationStojanov, D. A., Aracki-Trenkic, A., Vojinovic, S., Benedeto-Stojanov, D., & Ljubisavljevic, S. (2016) · European Radiology · doi:10.1007/s00330-015-3879-9 · Cited by 211
Wertman, R., Altun, E., Martin, D. R., Mitchell, D. G., Leyendecker, J. R., O'Malley, R. B., Parsons, D. J., Fuller, E. R., & Semelka, R. C. (2008) · Radiology · doi:10.1148/radiol.2483072093 · Cited by 187
Self-citationWeberling, L. D., Kieslich, P. J., Kickingereder, P., Wick, W., Bendszus, M., Schlemmer, H.-P., & Radbruch, A. (2015) · Investigative Radiology · doi:10.1097/rli.0000000000000206 · Cited by 168
Idée, J.-M., Port, M., Medina, C., Lancelot, E., Fayoux, E., Ballet, S., & Corot, C. (2008) · Toxicology · doi:10.1016/j.tox.2008.03.012 · Cited by 161
Gadolinium Chloride Toxicity in the Rat
Spencer, A. J., Wilson, S. A., Batchelor, J. F., Reid, A., Pees, J., & Harpur, E. S. (1997) · Toxicologic Pathology · doi:10.1177/019262339702500301 · Cited by 146
Gadolinium‐induced oxidative stress triggers endoplasmic reticulum stress in rat cortical neurons
Xia, Q., Feng, X., Huang, H., Du, L., Yang, X., & Wang, K. (2010) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.2010.07162.x · Cited by 119
Nephrogenic Systemic Fibrosis: History and Epidemiology
Thomsen, H. S. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2009.05.003 · Cited by 107
Roccatagliata, L., Vuolo, L., Bonzano, L., Pichiecchio, A., & Mancardi, G. (2009) · Radiology · doi:10.1148/radiol.2511081269 · Cited by 106
Feng, X., Xia, Q., Yuan, L., Yang, X., & Wang, K. (2010) · NeuroToxicology · doi:10.1016/j.neuro.2010.04.003 · Cited by 106
Quarles, L. D., Hartle, J. E., Middleton, J. P., et al. (1994) · Journal of Cellular Biochemistry · doi:10.1002/jcb.240560115 · Cited by 94
Gadolinium as a CT Contrast Agent: Assessment in a Porcine Model
Gierada, D. S., & Bae, K. T. (1999) · Radiology · doi:10.1148/radiology.210.3.r99mr06829 · Cited by 84
Varani, J., DaSilva, M., Warner, R. L., Deming, M. O., Barron, A. G., Johnson, K. J., & Swartz, R. D. (2009) · Investigative Radiology · doi:10.1097/rli.0b013e31818f76b5 · Cited by 80
Schroeder, J. A., Weingart, C., Coras, B., Haußer, I., Reinhold, S. W., Mack, M., Seybold, V., VOGT, T. M., Banas, B., Hofstaedter, F., et al. (2008) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.00100108 · Cited by 76
Edward, M., Quinn, J. A., Burden, A. D., Newton, B. B., & Jardine, A. G. (2010) · Radiology · doi:10.1148/radiol.10091131 · Cited by 63
Fretellier, N., Idée, J., Guérret, S., Hollenbeck, C., Hartmann, D. J., González, W., Pujolle-Robic, C., Port, M., & Corot, C. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181f54044 · Cited by 55
Nephrogenic Systemic Fibrosis and Management of High-risk Patients
Altun, E., Semelka, R. C., & Cakit, C. (2009) · Academic Radiology · doi:10.1016/j.acra.2009.01.001 · Cited by 45
Self-citationFibroblast Response to Gadolinium
Bhagavathula, N., Dame, M. K., DaSilva, M., Jenkins, W., Aslam, M. N., Perone, P., & Varani, J. (2010) · Investigative Radiology · doi:10.1097/rli.0b013e3181e943d2 · Cited by 39
Imaging of Bilateral Striopallidodentate Calcinosis
Ogi, S., Fukumitsu, N., Tsuchida, D., et al. (2002) · Clinical Nuclear Medicine · doi:10.1097/00003072-200210000-00008 · Cited by 34
Cited by
Aboyans, V., Ricco, J.-B., Bartelink, M.-L. E. L., Björck, M., Brodmann, M., Cohnert, T., Collet, J.-P., Czerny, M., De Carlo, M., Debus, S., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehx095 · Cited by 3,293
Aboyans, V., Ricco, J.-B., Bartelink, M.-L. E. L., Björck, M., Brodmann, M., Cohnert, T., Collet, J.-P., Czerny, M., De Carlo, M., Debus, S., et al. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2017.07.018 · Cited by 963
Gadolinium-based contrast agent toxicity: a review of known and proposed mechanisms
Rogosnitzky, M., & Branch, S. (2016) · BioMetals · doi:10.1007/s10534-016-9931-7 · Cited by 766
Halliday, A., & Bax, J. J. (2018) · European Journal of Vascular and Endovascular Surgery · doi:10.1016/j.ejvs.2018.03.004 · Cited by 651
Magnetic nanoparticles in nanomedicine: a review of recent advances
Wu, K., Su, D., Liu, J., Saha, R., & Wang, J.-P. (2019) · Nanotechnology · doi:10.1088/1361-6528/ab4241 · Cited by 509
Metadata
- Authors
- Ramalho, J., Semelka, R. C., Ramalho, M., Nunes, R. H., AlObaidy, M., & Castillo, M.
- Venue
- American Journal of Neuroradiology
- Published
- 2015-12-10
- Volume
- 37
- Issue
- 7
- Pages
- 1192-1198
- ISSN
- 0195-6108 (ISSN-L)
- 1936-959X
- OpenAlex
- W2191128648
- Cited by
- 453
- References
- 38
- FWCI
- 15.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.