The study of rheological effects on vascular endothelial cells in culture
The DOI matches its Crossref record.
Abstract
A number of cell culture studies have been reported on the influence of shear stress on vascular endothelial cells. Although through such studies much has been learned about the effect of an endothelial cell's hydrodynamic environment on its structure and function, the reports indicate significant differences in methodology. Using cell shape as an indicator of differences that might result from differing methodologies, an investigation of the influence of selected variables has been carried out. The results presented indicate that not only are such variables as the level of shear stress and the duration of exposure important, but also substrate, media composition, characteristics of the cell itself, and the nature of the flow, e.g. whether it is steady state or pulsatile.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Heparan Sulfate Proteoglycan Is a Mechanosensor on Endothelial Cells
Florian, J. A., Kosky, J. R., Ainslie, K., Pang, Z., Dull, R. O., & Tarbell, J. M. (2003) · Circulation Research · doi:10.1161/01.res.0000101744.47866.d5 · Cited by 615
Remodeling of an acellular collagen graft into a physiologically responsive neovessel
Huynh, T., Abraham, G., Murray, J., Brockbank, K., Hagen, P.-O., & Sullivan, S. (1999) · Nature Biotechnology · doi:10.1038/15062 · Cited by 330
Probing transmembrane mechanical coupling and cytomechanics using magnetic twisting cytometry
Wang, N., & Ingber, D. E. (1995) · Biochemistry and Cell Biology · doi:10.1139/o95-041 · Cited by 230
“1991), and application of fluid shear stresses (Levesque and Nerem 1989; Davies and Tripathi 1993; Barbee et al. 1994).”
BackgroundAnalysis of Cell Mechanics in Single Vinculin-Deficient Cells Using a Magnetic Tweezer
Alenghat, F. J., Fabry, B., Tsai, K. Y., Goldmann, W. H., & Ingber, D. E. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.3636 · Cited by 216
Metadata
- Authors
- Levesque, M. J., & Nerem, R. M.
- Venue
- Biorheology
- Publisher
- SAGE Publications
- Published
- 1989-06-01
- Volume
- 26
- Issue
- 2
- Pages
- 345-357
- ISSN
- 0006-355X (ISSN-L)
- 1878-5034
- OpenAlex
- W2436474770
- Cited by
- 59
- References
- 0
- FWCI
- 1.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The study of rheological effects on vascular endothelial cells in culture. https://app.cochat.ai/papers/10.3233/bir-1989-26218
- The paper
- Levesque, M. J., & Nerem, R. M. (1989). The study of rheological effects on vascular endothelial cells in culture. Biorheology. https://doi.org/10.3233/bir-1989-26218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.