Dobutamine stress magnetocardiography for the detection of significant coronary artery stenoses—a prospective study in comparison with simultaneous 12-lead electrocardiography
The DOI matches its Crossref record; 39 of the 40 references it cites were found in a registry or an index.
Abstract
Background: Exercise electrocardiography is an imperfect test for the detection of coronary artery disease (CAD). Magnetocardiography detects cardiac electrical disturbances associated with myocardial ischemia. We prospectively investigated the accuracy of high-dose dobutamine stress magnetocardiography (DS-MCG) and simultaneous electrocardiography (DS-ECG) for the detection of significant CAD. Methods: 100 patients with an intermediate pre-test probability for CAD underwent DS-MCG using a multichannel magnetometer prior to invasive coronary angiography. Patients were examined at rest and during a standard dobutamine–atropine scheme. Significant reduction of epicardial current strength/density during stress, reconstructed from the magnetic field map and superposed on a virtual heart model indicates myocardial ischemia. A 12-lead DS-ECG was recorded simultaneously. Significant coronary artery stenosis was defined as ≥70% of lumen reduction. Results: Without β-blocker all 100 patients reached the targeted heart rate. The image quality of DS-MCG and DS-ECG was sufficient for analysis in all patients. In 19 patients CAD was ruled out angiographically. Thirty two or seven patients revealed coronary artery stenoses of 30–49% or of 50–69%, respectively. In 42 patients we found significant stenoses of ≥70%. In 41 of these patients DS-MCG revealed myocardial ischemia. The sensitivity of DS-MCG and DS-ECG for the detection of significant coronary artery stenosis was 97.6% and 26.2%, the specificity of DS-MCG and DS-ECG 82.8% and 82.8%, respectively. Conclusions: DS-MCG can be performed with a standard dobutamine/atropine stress protocol. DS-MCG yields a significantly higher accuracy for the detection of significant coronary artery stenosis than DS-ECG.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“However, despite the great clinical significance of movable MCG systems, few studies have been reported (14, 15, 23–27).”
From A movable unshielded magnetocardiography system (2023) · cites this paper as [25]
In the citing paper
“The usefulness of MCG for a better understanding of the arrhythmogenic mechanisms underlying the high-risk J syndromes (225, 327–336); the identification of atrial arrhythmogenic vulnerability (248), of left atrial dysfunction (330), and of the atrial propagation pathways (228); and the dominant frequencies (181, 183, 189, 232) in patients with atrial fibrillation, as well as providing accurate”
From Clinical magnetocardiography: the unshielded bet—past, present, and future (2023) · cites this paper as [332]
Citations
Cites
Analysis of probability as an aid in the clinical diagnosis of coronary artery disease.
Diamond, G. A., & Forrester, J. S. (1979) · New England Journal of Medicine · doi:10.1056/nejm197906143002402 · Cited by 2,664 · cited 1×
“…artery disease (CAD) the need for further evaluation by non-invasive and invasive diagnosis can be simply estimated by calculating the pre-test probability of the disease on the basis of patient’s history, physical examination, and initial tests including laboratory tests and ECG at rest [1,2].”
Committee Members, Gibbons, R. J., Balady, G. J., Timothy Bricker, J., Chaitman, B. R., Fletcher, G. F., Froelicher, V. F., Mark, D. B., McCallister, B. D., Mooss, A. N., et al. (2002) · Circulation · doi:10.1161/01.cir.0000034670.06526.15 · Cited by 2,607
Picano, E., Mathias, W., A, P., R, B., & M, P. (1994) · The Lancet · doi:10.1016/s0140-6736(94)90508-8 · Cited by 394
Paetsch, I., Jahnke, C., Wahl, A., Gebker, R., Neuss, M., Fleck, E., & Nagel, E. (2004) · Circulation · doi:10.1161/01.cir.0000138927.00357.fb · Cited by 333
Morise, A. P., & Diamond, G. A. (1995) · American Heart Journal · doi:10.1016/0002-8703(95)90072-1 · Cited by 191 · cited 2×
“Although the ECG tolerance test represents a cornerstone in non-invasive diagnostics of CAD, its accuracy is comparatively poor [3,4].”
BackgroundElhendy, A., O'Leary, E. L., Xie, F., McGrain, A. C., Anderson, J. R., & Porter, T. R. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2004.08.059 · Cited by 179 · cited 1×
“Cardiac imaging techniques like stress echocardiography [5–8], contrast echocardiography [9–13], nuclear imaging (SPECT, PET) [8,14– 18], or cardiac computed tomography [19–22] have demonstrated significantly better diagnostic values.”
BackgroundHeinle, S. K., Noblin, J., Goree-Best, P., Mello, A., Ravad, G., Mull, S., Mammen, P., & Grayburn, P. A. (2000) · Circulation · doi:10.1161/01.cir.102.1.55 · Cited by 173
Berman, D. S., Hachamovitch, R., Shaw, L. J., Friedman, J. D., Hayes, S. W., Thomson, L., Fieno, D. S., Germano, G., Slomka, P. J., Wong, N. D., et al. (2006) · PubMed · Cited by 159
Shimoni, S., Zoghbi, W. A., Xie, F., Kricsfeld, D., Iskander, S., Gobar, L. S., Mikati, I. A., Abukhalil, J. M., Verani, M. S., O’Leary, E. L., et al. (2001) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(00)01179-7 · Cited by 151
Holland, R. P., & Brooks, H. (1975) · Circulation Research · doi:10.1161/01.res.37.4.471 · Cited by 148 · cited 3×
“Nevertheless, changes of the ionic currents of the action potential are the first consequences of cellular hypoxia and occur long before discernible functional disturbances of the myocardium [37,38,52].”
BackgroundInfluential
Cited by
A movable unshielded magnetocardiography system
Xiao, W., Sun, C., Shen, L., Feng, Y., Liu, M., Wu, Y., Liu, X., Wu, T., Peng, X., & Guo, H. (2023) · Science Advances · doi:10.1126/sciadv.adg1746 · Cited by 116
Kwong, J. S. W., Leithäuser, B., Park, J.-W., & Yu, C.-M. (2013) · International Journal of Cardiology · doi:10.1016/j.ijcard.2012.12.056 · Cited by 103
“2 and 3) [38].”
MethodSelf-citationClinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Pena, M. E., Pearson, C. L., Goulet, M. P., Kazan, V. M., DeRita, A. L., Szpunar, S. M., & Dunne, R. B. (2020) · IJC Heart & Vasculature · doi:10.1016/j.ijcha.2019.100466 · Cited by 70
Magnetocardiography for the detection of myocardial ischemia
Her, A., Dischl, D., Kim, Y. H., Kim, S., & Shin, E. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1242215 · Cited by 68
“(43) Abnormalities of the mean time isointegral MFM Acute MI/ Patients with MI with a history of prolonged cardiac pain and diagnostic enzyme level elevations who were either previously diagnosed using standard 12-lead EKG, as having anterior (4) or inferior (7) Q wave MI or non-Q wave MI (11)/Normal controls (9) Shie…”
MethodInfluentialOptically pumped magnetometers enable a new level of biomagnetic measurements
Sander, T. H., Jodko-Władzińska, A., Hartwig, S., Brühl, R., & Middelmann, T. (2019) · Advanced Optical Technologies · doi:10.1515/aot-2020-0027 · Cited by 44
Park, J.-W., Shin, E.-S., Ann, S. H., Gödde, M., Park, L. S.-I., Brachmann, J., Vidal-Lopez, S., Wierzbinski, J., Lam, Y.-Y., & Jung, F. (2015) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-141912 · Cited by 29
“Stress recordings were acquired by bicycle exercise test in 45 patients and dobutamine hydrochloride (Dobutamine 280 mg/50ml; Fresenius AG, Bad Homburg, Germany) test in 2 patients who were unable to exercise, as described previously [40].”
Self-citationAgarwal, R., Saini, A., Alyousef, T., & Umscheid, C. A. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2012.00538.x · Cited by 28
Wang, Y., Zhao, Z., Chai, Z., Fang, J., & Chen, M. (2023) · The FASEB Journal · doi:10.1096/fj.202300201rr · Cited by 27
“Park et al. 94 first showed promising results for rule-in CAD patients with intermediate pretest probability, with a high sensitivity of 97.6% compared with 26.2% for ECG, but with the same specificity as ECG.”
ResultInfluentialWu, Y., Lin, L. C., Tseng, W., Liu, Y., Kao, H.-L., Lin, M. S., Huang, H. C., Wang, S. Y., Horng, H. E., Yang, H. C., et al. (2014) · PubMed · Cited by 22
Her, A., & Park, J. (2016) · Yonsei Medical Journal · doi:10.3349/ymj.2016.57.6.1305 · Cited by 18
Self-citationAdvances of magnetocardiography in application of adult and fetal cardiac diseases
Li, J., Shen, Y., Shen, C., Ning, X., & Xiang, M. (2025) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2025.1522467 · Cited by 15
Huang, X., Hua, N., Tang, F., & Zhang, S. (2020) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt-20-121 · Cited by 10
“Several MCG parameters calculated along the ST interval and T-wave were typically abnormal at rest in patients with CAD, and appear to be sensitive diagnostic parameters (3,5,6,11,15-17).”
BackgroundMagnetocardiography for the diagnosis of non-obstructive coronary artery disease1
Shin, E., Park, J., & Lim, D. (2018) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-189106 · Cited by 9
“Magnetocardiography (MCG) is non-invasive and contactless, and does not require contrast material or radiation to record cardiac electromagnetic activity with high resolution, which allows the recording of the magnetic fields generated by the electrical activity of the heart [8, 9].”
Self-citationBrisinda, D., Fenici, R., & Smars, P. (2022) · Contemporary Cardiology · doi:10.1007/978-3-031-05520-1_17 · Cited by 6
Krause, H., & Dong, H. (2017) · Springer series on chemical sensors and biosensors · doi:10.1007/5346_2017_13 · Cited by 6
“Applications include the detection of myocardial ischemia [21] and viability [22], coronary artery disease [23,24,25], arrhythmogenic risk assessment, imaging of arrhythmogenic sites such as the Wolff-Parkinson-White syndrome [26] or ventricular arrhythmia [27].”
BackgroundSpecial article Magnetocardiography in clinical cardiology. Status quo and future applications
Leithäuser, B., Jung, F., & Park, J. (2011) · Advances in Interventional Cardiology · doi:10.5114/pwki.2011.24739 · Cited by 6
Self-citationYang, M., Sun, C., Zhao, B., Wu, B., Xiang, J., Xu, M., Wu, T., Zhang, J., Xu, W., & Guo, H. M. (2024) · medRxiv · doi:10.1101/2024.01.31.24302044 · Cited by 3
Ma, Z., Xu, F., Yang, S., Zhang, H., Liu, L., Zhou, S., Feng, L., Tu, C., Song, X., & Zhang, H. (2025) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2025.154085 · Cited by 2
Bioelectric and biomagnetic measurements are differentially sensitive to spiral currents
Haueisen, J., Dietzel, A., Liehr, M., Weiser, T., Elsarnagawy, T., & Bellemann, M. E. (2011) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2011.104 · Cited by 2
Wearable Wireless Dual-Plane OPM-MCG System for Rest/Stress Cardiac Magnetic Field Measurement
Li, T., Cheng, H., Wang, D., Yin, Y., Li, C., Gu, W., Jiang, C., Lyu, B., & Gao, J. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3595239 · Cited by 3
“M AGNETOCARDIOGRAPHY (MCG) is a contactless and noninvasive method that measures the magnetic fields produced by cardiac electrical activities [1], [2], [3].”
Feng, L., Zhao, X., Yang, S., Liu, L., Ma, Z., Zhang, H., Xiang, J., Ding, M., Tu, C., Song, X., et al. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100661 · Cited by 1
“Several studies have demonstrated that stress exercise can enhance the sensitivity and specificity of MCG in diagnosing myocardial ischemia [16 – 18].”
Leithäuser, B., Jung, F., & Park, J. W. (2012) · Der Kardiologe · doi:10.1007/s12181-012-0401-3
Self-citationChandran, K., Senthilnathan, S., Patel, R., & Mani, A. (2025) · International Journal of Applied Electromagnetics and Mechanics · doi:10.1177/13835416251361647
Meta-analysis of magnetocardiography in diagnosing coronary artery disease and myocardial ischemia
Li, J., Yan, M., Xiang, M., & Ning, X. (2026) · Next research. · doi:10.1016/j.nexres.2026.101496 · Cited by 1
Application of artificial intelligence on magnetocardiology
Mockler, J., Yang, S., Schmid, L., Bannasch, S., Maier, A., & Park, J. W. (2025) · Clinical Hemorheology and Microcirculation · doi:10.1177/13860291251378923 · Cited by 1
Self-citationMagnetocardiography in diagnosis of MINOCA: a case series
Xue, X., Zhang, J., Zhou, Y., Zhu, Y., Liang, J., Tian, K., Xu, D., Chen, Y., Zhang, X., & Xiang, M. (2026) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2026.1759132
Metadata
- Authors
- Park, J.-W., Leithäuser, B., Vršansky, M., & Jung, F.
- Affiliations
- Lausitzer Seenland Klinikum (DE)
- Institute for Heart and Circulation Research, Hoyerswerda, Germany
- Cardiology/Angiology Division, Hoyerswerda Hospital, Hoyerswerda, Germany
- Berlin-Brandenburger Centrum für Regenerative Therapien (DE)
- ORCID
- Jung, F.
- Venue
- Clinical Hemorheology and Microcirculation
- Publisher
- SAGE Publications
- Published
- 2008-06
- Volume
- 39
- Issue
- 1-4
- Pages
- 21-32
- ISSN
- 1386-0291 (ISSN-L)
- 1875-8622
- OpenAlex
- W314671638
- Cited by
- 27
- References
- 40
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 1 · 2023: 4 · 2022: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 2
- FWCI
- 0.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
- Locations
- Clinical Hemorheology and Microcirculation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
- Keywords
- coronary artery stenosis, coronary artery disease, myocardial ischemia, 12-lead ECG, magnetic field mapping, virtual heart model, diagnostic accuracy, exercise electrocardiography
- MeSH terms
- Aged, Coronary Artery Disease, Dobutamine, Electrocardiography, Electrophysiology, Female, Humans, Male, Middle Aged, Models, Biological, Probability, Prospective Studies, Signal Processing, Computer-Assisted, Coronary Angiography, Coronary Stenosis, Magnetocardiography
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.