CoChat

Dobutamine stress magnetocardiography for the detection of significant coronary artery stenoses—a prospective study in comparison with simultaneous 12-lead electrocardiography

Park, J.-W., Leithäuser, B., Vršansky, M., Jung, F. · 2008 · Clinical Hemorheology and Microcirculation

The DOI matches its Crossref record; 39 of the 40 references it cites were found in a registry or an index.

Abstract

Background: Exercise electrocardiography is an imperfect test for the detection of coronary artery disease (CAD). Magnetocardiography detects cardiac electrical disturbances associated with myocardial ischemia. We prospectively investigated the accuracy of high-dose dobutamine stress magnetocardiography (DS-MCG) and simultaneous electrocardiography (DS-ECG) for the detection of significant CAD. Methods: 100 patients with an intermediate pre-test probability for CAD underwent DS-MCG using a multichannel magnetometer prior to invasive coronary angiography. Patients were examined at rest and during a standard dobutamine–atropine scheme. Significant reduction of epicardial current strength/density during stress, reconstructed from the magnetic field map and superposed on a virtual heart model indicates myocardial ischemia. A 12-lead DS-ECG was recorded simultaneously. Significant coronary artery stenosis was defined as ≥70% of lumen reduction. Results: Without β-blocker all 100 patients reached the targeted heart rate. The image quality of DS-MCG and DS-ECG was sufficient for analysis in all patients. In 19 patients CAD was ruled out angiographically. Thirty two or seven patients revealed coronary artery stenoses of 30–49% or of 50–69%, respectively. In 42 patients we found significant stenoses of ≥70%. In 41 of these patients DS-MCG revealed myocardial ischemia. The sensitivity of DS-MCG and DS-ECG for the detection of significant coronary artery stenosis was 97.6% and 26.2%, the specificity of DS-MCG and DS-ECG 82.8% and 82.8%, respectively. Conclusions: DS-MCG can be performed with a standard dobutamine/atropine stress protocol. DS-MCG yields a significantly higher accuracy for the detection of significant coronary artery stenosis than DS-ECG.

Overview

Integrity signals

Registry

Crossref · 10.3233/ch-2008-1064

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Cited by

See all 27

Metadata

Authors
Park, J.-W., Leithäuser, B., Vršansky, M., & Jung, F.
Affiliations
  • Lausitzer Seenland Klinikum (DE)
  • Institute for Heart and Circulation Research, Hoyerswerda, Germany
  • Cardiology/Angiology Division, Hoyerswerda Hospital, Hoyerswerda, Germany
  • Berlin-Brandenburger Centrum für Regenerative Therapien (DE)
Venue
Clinical Hemorheology and Microcirculation
Published
2008-06
Volume
39
Issue
1-4
Pages
21-32
ISSN
  • 1386-0291 (ISSN-L)
  • 1875-8622
OpenAlex
W314671638
Cited by
27
References
40
Citations by year
2026: 2 · 2025: 6 · 2024: 1 · 2023: 4 · 2022: 1 · 2020: 2 · 2019: 1 · 2018: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2014: 1 · 2013: 1 · 2012: 2
FWCI
0.51
Type
journal article
Language
en
Open access
closed
Licence
journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
Locations
  • Clinical Hemorheology and Microcirculation (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Acute Myocardial Infarction Research
Keywords
coronary artery stenosis, coronary artery disease, myocardial ischemia, 12-lead ECG, magnetic field mapping, virtual heart model, diagnostic accuracy, exercise electrocardiography
MeSH terms
Aged, Coronary Artery Disease, Dobutamine, Electrocardiography, Electrophysiology, Female, Humans, Male, Middle Aged, Models, Biological, Probability, Prospective Studies, Signal Processing, Computer-Assisted, Coronary Angiography, Coronary Stenosis, Magnetocardiography

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.