Controllable mechanical tremor reduction. Assessment of two orthoses
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
This paper presents the results of clinical trials performed using two upper-limb orthotic devices for tremor suppression, developed under the Fifth Framework Project DRIFTS (Contract QLK6-CT-2002-00536). The orthoses were tested on six subjects presenting various aetiological forms of tremor. Two different strategies of tremor reduction were investigated: viscous friction and notch filtering. The results obtained from the trials suggest that ambulatory and controllable mechanical suppression of tremor by orthotic means is a feasible intervention. The degree of tremor reduction is dependent upon the power associated with tremor. Expected reduction of tremor can be as high as 98% in severe cases. There are hints that for many persons suffering with tremor active mechanical suppression of tremor can produce a reinforcing feedback: when participants perceived and initial reduction of tremor due to the orthosis, they exhibited a further spontaneous reduction of the tremor. There are also indications in some participants that tremor can migrate from a controlled joint to other free joints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pathological tremor management: modelling, compensatory technology and evaluation
Rocon, E., Belda-Lois, J. M., Sanchez-Lacuesta, J. J., & Pons, J. L. (2004) · Technology and Disability · doi:10.3233/tad-2004-16102 · Cited by 89
Self-citationRehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87 · cited 3×
“WOTAS is able to operate in either of two modes: The ‘active’ mode in which the system is configured as a notch filter with self adjusting trakcing of main frequency [13] and the ‘passive’ mode in which the system is able to simulate different parameters of viscosity, inertia and mass for tremor suppression with loadi…”
Self-citationDynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81 · cited 1×
“The DRIFTS Project aimed to create wearable active orthoses that suppress upper-limb tremor while allowing natural movement [9].”
Self-citationLoureiro, R. C. V., Belda-Lois, J. M., Lima, E. R., Pons, J. L., Sanchez-Lacuesta, J. J., & Harwin, W. S. (2005) · 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005. · doi:10.1109/icorr.2005.1501065 · Cited by 70 · cited 1×
“To facilitate reaching the DRIFTS objectives, two systems were developed under the project: – Double Viscous-Beam-based orthosis ( DVB ) [7]: A close-to-commercial device developed and improving upon the original Viscous-Beam concept.”
Self-citation
Cited by
Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Taheri, B., Case, D., & Richer, E. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317948 · Cited by 53
“, a magnetorheological damper (MRD) [11]–[13], or a passive damper [12], [14], [15].”
BackgroundAdaptive band-pass filter (ABPF) for tremor extraction from inertial sensor data
Popović, L. Z., Šekara, T. B., & Popović, M. B. (2010) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2010.03.018 · Cited by 29
Active tremor estimation and suppression in human elbow joint
Taheri, B., Case, D., & Richer, E. (2011) · ASME 2011 Dynamic Systems and Control Conference and Bath/ASME Symposium on Fluid Power and Motion Control, Volume 2 · doi:10.1115/dscc2011-6185 · Cited by 18
“An exoskeleton can then be employed to generate a motion equal but opposite to the tremor [11, 13, 17].”
MethodTremor Suppression With Mechanical Vibration Stimulation
Liu, W., Kai, T., & Kiguchi, K. (2020) · IEEE Access · doi:10.1109/access.2020.3045023 · Cited by 13
Metadata
- Authors
- Belda-Lois, J. M., Martinez-Reyero, A. I., Castillo, A., Rocon, E., Pons, J. L., Loureiro, R., Manto, M., Normie, L., & Soede, M.
- Venue
- Technology and Disability
- Publisher
- SAGE Publications
- Published
- 2007-11
- Volume
- 19
- Issue
- 4
- Pages
- 169-178
- ISSN
- 1055-4181 (ISSN-L)
- 1878-643X
- OpenAlex
- W1865246602
- Cited by
- 29
- References
- 4
- FWCI
- 0.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- journals.sagepub.com/page/policies/text-and-data-mining-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Controllable mechanical tremor reduction. Assessment of two orthoses. https://app.cochat.ai/papers/10.3233/tad-2007-19402
- The paper
- Belda-Lois, J. M., Martinez-Reyero, A. I., Castillo, A., Rocon, E., Pons, J. L., Loureiro, R., Manto, M., Normie, L., & Soede, M. (2007). Controllable mechanical tremor reduction. Assessment of two orthoses. Technology and Disability. https://doi.org/10.3233/tad-2007-19402
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.