Micro-compression: a novel technique for the nondestructive assessment of local bone failure
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Many bones within the axial and appendicular skeleton are subjected to repetitive, cyclic loading during the course of ordinary daily activities. If this repetitive loading is of sufficient magnitude or duration, fatigue failure of the bone tissue may result. In clinical orthopedics, trabecular fatigue fractures are observed as compressive stress fractures in the proximal femur, vertebrae, calcaneus and tibia, and are often preceded by buckling and bending of microstructural elements. However, the relative importance of bone density and architecture in the etiology of these fractures is poorly understood. The aim of the study was to investigate failure mechanisms of 3D trabecular bone using micro-computed tomography (microCT). Because of its nondestructive nature, microCT represents an ideal approach for performing not only static measurements of bone architecture but also dynamic measurements of failure initiation and propagation as well as damage accumulation. For the purpose of the study, a novel micro-compression device was devised to measure loaded trabecular bone specimens directly in a micro-tomographic system. The measurement window in the device was made of a radiolucent, highly stiff plastic to enable X-rays to penetrate the material. The micro-compressor has an outer diameter of 19 mm and a total length of 65 mm. The internal load chamber fits wet or dry bone specimens with maximal diameters of 9 mm and maximal lengths of 22 mm. For the actual measurement, first, the unloaded bone is measured in the microCT. Second, a load-displacement curve is recorded where the load is measured with an integrated mini-button load cell and the displacement is computed directly from the microCT scout-view. For each load case, a 3D snap-shot of the structure under load is taken providing 34 microm nominal resolution. Initial measurements included specimens from bovine tibiae and whale spine to investigate the influence of the structure type on the failure mechanism. In a rod-like type of architecture as seen in the whale spine, structural failure was described by an initial buckling and bending of structural elements followed by a collapse of the overloaded trabeculae. In the more plate-like bovine tibial architecture, buckling and bending could not be observed. Failure rather seemed to occur instantaneously. In conclusion, micro-compression in combination with 3D microCT allows visualization of failure initiation and propagation and monitoring of damage accumulation in a nondestructive way. We expect these findings to improve our understanding of the relative importance of density, architecture and load in the etiology of spontaneous fractures of the hip and the spine. Eventually, this improved understanding may lead to more successful approaches to the prevention of age-related fractures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001
Self-citationvan Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865 · cited 2×
“Desk-top μCT has been used extensively for different research projects involving microstructural bone and biomaterials [8,25,26,49,51,53,54,68,69].”
How Many Women Have Osteoporosis?
Melton, L. J., Chrischilles, E. A., Cooper, C., Lane, A. W., & Riggs, B. L. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2005.20.5.886 · Cited by 708
Mosekilde, L., Mosekilde, L., & Danielsen, C. C. (1987) · Bone · doi:10.1016/8756-3282(87)90074-3 · Cited by 492
Ciarelli, M. J., Goldstein, S. A., Kuhn, J. L., Cody, D. D., & Brown, M. B. (1991) · Journal of Orthopaedic Research · doi:10.1002/jor.1100090507 · Cited by 401 · cited 1×
“On an individual basis, density alone accounts for 10–90% of the variation in the strength of trabecular bone [6].”
Fabric and elastic principal directions of cancellous bone are closely related
Odgaard, A., Kabel, J., van Rietbergen, B., Dalstra, M., & Huiskes, R. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(96)00177-7 · Cited by 338
A comparison of the fatigue behavior of human trabecular and cortical bone tissue
Choi, K., & Goldstein, S. A. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90051-2 · Cited by 247
Failure mechanisms in human vertebral cancellous bone
Fyhrie, D. P., & Schaffler, M. B. (1994) · Bone · doi:10.1016/8756-3282(94)90900-8 · Cited by 215 · cited 1×
“Only few attempts have been made to assess and quantify the mechanical behavior of bone beyond initial yielding and failure in compact [8,38] and in trabecular bone [17,23,32,34,56,73].”
Age-related differences in post-yield damage in human cortical bone. Experiment and model
Courtney, A. C., Hayes, W. C., & Gibson, L. J. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)84542-8 · Cited by 131
Self-citation
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue
Bayraktar, H. H., Morgan, E. F., Niebur, G. L., Morris, G. E., Wong, E. K., & Keaveny, T. M. (2004) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00257-4 · Cited by 1,142
Biomechanics of cellular solids
Gibson, L. J. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.027 · Cited by 961
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Niebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431
Micro-Computed Tomography—Current Status and Developments
Ritman, E. L. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140130 · Cited by 360
Micro-CT in small animal and specimen imaging
Holdsworth, D. W., & Thornton, M. M. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(02)02004-8 · Cited by 334
Effects of non-enzymatic glycation on cancellous bone fragility
Tang, S. Y., Zeenath, U., & Vashishth, D. (2007) · Bone · doi:10.1016/j.bone.2006.12.056 · Cited by 283
Damage in trabecular bone at small strains
Morgan, E., Yeh, O., & Keaveny, T. (2005) · European Journal of Morphology · doi:10.1080/09243860500095273 · Cited by 59
Metadata
- Authors
- Müller, R., Gerber, S. C., & Hayes, W. C.
- Venue
- Technology and Health Care
- Publisher
- SAGE Publications
- Published
- 1998-12-01
- Volume
- 6
- Issue
- 5-6
- Pages
- 433-444
- ISSN
- 0928-7329 (ISSN-L)
- 1878-7401
- OpenAlex
- W2131802574
- Cited by
- 112
- References
- 9
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.