CoChat

Interfacing the body’s own sensing receptors into neural prosthesis devices

Haugland, Morten, Sinkjær, Thomas · 1999 · Technology and Health Care
Cited by 46

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Functional Electric Stimulation (FES) is today available as a tool in muscle activation used in picking up objects, in standing and walking, in controlling bladder emptying, and for breathing. Despite substantial progress over nearly three decades of development, many challenges remain to provide a more efficient functionality of FES systems. The most important of these is an improved control of the activated muscles. Instead of artificial sensors for feedback, new developments in electrodes to do long-term and reliable recordings from peripheral nerves emphasize the use of the body's own sensors. These are already installed and optimised through millions of years of natural evolution. This paper presents recent results on a system using electrical stimulation of motor nerves to produce movement and using the natural sensors as feedback signals to control the stimulation that can replicate some of the functions of the spinal cord and its communication with the brain. We have used the nerve signal recorded from cutaneous nerves in two different human applications: (1) to replace the external heel switch of a system for correction of spastic drop foot by peroneal stimulation, and (2) to provide an FES system for restoration of hand grasp with sensory feedback from the fingertip. For the bladder function, the sacral root stimulator is a useful control tool in emptying the bladder. To decide when to stimulate, we are at present carrying out experiments on pigs and cats using cuff electrodes on the pelvic nerve and sacral roots to record the neural information from bladder afferents. This information can potentially be used to inhibit unwanted bladder contractions and to trigger the FES system and thereby bladder emptying. Future research will show whether cuffs and other types of electrodes can be used to reliably extract signals from the large number of other receptors in the body to improve and expand on the use of natural sensors in clinical FES systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3233/thc-1999-7603

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 46

Metadata

Authors
Haugland, M., & Sinkjær, T.
Venue
Technology and Health Care
Published
1999-12-01
Volume
7
Issue
6
Pages
393-399
ISSN
  • 0928-7329 (ISSN-L)
  • 1878-7401
OpenAlex
W1503705660
Cited by
46
References
6
FWCI
0.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Interfacing the body’s own sensing receptors into neural prosthesis devices. https://app.cochat.ai/papers/10.3233/thc-1999-7603
The paper
Haugland, M., & Sinkjær, T. (1999). Interfacing the body’s own sensing receptors into neural prosthesis devices. Technology and Health Care. https://doi.org/10.3233/thc-1999-7603

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.