A pilot investigation of new superparamagnetic iron oxide (ferumoxytol) as a contrast agent for cardiovascular MRI
The DOI matches its Crossref record.
Abstract
Purpose: To evaluate the imaging potential of ferumoxytol, a new superparamagnetic iron oxide colloidal blood pool contrast agent. Materials and Methods: Magnetic resonance (MR) imaging at 1.5 Tesla was performed before and after intravenous injection of ferumoxytol using escalating doses of 0.4, 0.8, 1.2 and 1.6 mg Fe/kg for a total of 4 mg Fe/kg in five subjects imaged with 3D MR Angiography (MRA) of the trifurcation after each dose. In five subjects cardiac cine MRI was performed pre and post 4.0 mg Fe/kg. Image quality was assessed by measuring signal to-noise ratio (SNR) and contrast-to-noise ratio (CNR) in the vascular structures. Pre- and post-dose urine and blood tests as well as EKG/vital sign monitoring were performed to evaluate safety and blood samples were collected for T1 relaxivity measurements. Results: Cumulative doses of 0, 0.4, 1.2, 2.4 and 4 mg Fe/kg yielded mean SNR in the arteries of 10, 16, 39, 57 and 69 respectively indicating that the higher doses produced higher SNR on 3D vascular images. Similarly aorta SNR on 2D time-of-flight increased from 11.8 without Fe to 15.4 post Fe (p = 0.004) indicating improved image quality on MRA sequences optimized for use without contrast. At 4 mg Fe/kg there was a substantial T1 shortening measured in the blood from 1990 ± 573 ms to 80 ± 42 ms (p < 0.0001), corresponding to the increased SNR. Images of large vascular structures including cardiac chambers, aorta, and pulmonary arteries were excellent post ferumoxytol but images of smaller arteries of the trifurcation were difficult to evaluate due to enhancement of the overlapping veins. No serious adverse events occurred. Conclusion: The new superparamagnetic iron oxide colloid ferumoxytol is a promising blood pool agent especially for cardiac, aorta and pulmonary imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Translation of Nanomedicine
Min, Y., Caster, J. M., Eblan, M. J., & Wang, A. Z. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00116 · Cited by 772
Nanopharmaceuticals (part 1): products on the market
Weissig, V., Pettinger, T., & Murdock, N. (2014) · International Journal of Nanomedicine · doi:10.2147/ijn.s46900 · Cited by 591
A Review of Clinical Translation of Inorganic Nanoparticles
Anselmo, A. C., & Mitragotri, S. (2015) · The AAPS Journal · doi:10.1208/s12248-015-9780-2 · Cited by 509
Emerging applications for ferumoxytol as a contrast agent in MRI
Bashir, M. R., Bhatti, L., Marin, D., & Nelson, R. C. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24691 · Cited by 371
Muldoon, L. L., Manninger, S., Pinkston, K. E., & Neuwelt, E. A. (2005) · Neurosurgery · doi:10.1093/neurosurgery/57.4.785 · Cited by 190
Clinical applications of iron oxide nanoparticles for magnetic resonance imaging of brain tumors
Iv, M., Telischak, N., Feng, D., Holdsworth, S. J., Yeom, K. W., & Daldrup-Link, H. E. (2015) · Nanomedicine · doi:10.2217/nnm.14.203 · Cited by 134
Schnorr, J., Wagner, S., Abramjuk, C., Wojner, I., Schink, T., Kroencke, T. J., Schellenberger, E., Hamm, B., Pilgrimm, H., & Taupitz, M. (2004) · Investigative Radiology · doi:10.1097/01.rli.0000133944.30119.cc · Cited by 54
Metadata
- Authors
- Prince, M. R., Zhang, H. L., Chabra, S. G., Jacobs, P., & Wang, Y.
- Venue
- Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics
- Publisher
- SAGE Publications
- Published
- 2003-11
- Volume
- 11
- Issue
- 4
- Pages
- 231-240
- ISSN
- 0895-3996 (ISSN-L)
- 1095-9114
- OpenAlex
- W263771170
- Cited by
- 73
- References
- 0
- FWCI
- 1.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.