Background: The risk of developing long-term complications of type 1 diabetes (T1D) is related to glycaemic control and is reduced by the use of intensive insulin treatment regimens: multiple daily injections (MDI) (≥ 4) and continuous subcutaneous insulin infusion (CSII). Despite a lack of evidence that the more expensive treatment with CSII is superior to MDI, both treatments are used widely within the NHS. Objectives: (1) To compare glycaemic control during treatment with CSII and MDI and (2) to determine safety and cost-effectiveness of the treatment, and quality of life (QoL) of the patients. Design: A pragmatic, open-label randomised controlled trial with an internal pilot and 12-month follow-up with 1 : 1 web-based block randomisation stratified by age and centre. Setting: Fifteen diabetes clinics in hospitals in England and Wales. Participants: Patients aged 7 months to 15 years. Interventions: Continuous subsutaneous insulin infusion or MDI initiated within 14 days of diagnosis of T1D. Data sources: Data were collected at baseline and at 3, 6, 9 and 12 months using paper forms and were entered centrally. Data from glucometers and CSII were downloaded. The Health Utilities Index Mark 2 was completed at each visit and the Pediatric Quality of Life Inventory (PedsQL, diabetes module) was completed at 6 and 12 months. Costs were estimated from hospital patient administration system data. Outcomes: The primary outcome was glycosylated haemoglobin (HbA 1c) concentration at 12 months. The secondary outcomes were (1) HbA 1c concentrations of < 48 mmol/mol, (2) severe hypoglycaemia, (3) diabetic ketoacidosis (DKA), (4) T1D- or treatment-related adverse events (AEs), (5) change in body mass index and height standard deviation score, (6) insulin requirements, (7) QoL and (8) partial remission rate. The economic outcome was the incremental cost per quality-adjusted life-year (QALY) gained. Results: A total of 293 participants, with a median age of 9.8 years (minimum 0.7 years, maximum 16 years), were randomised (CSII, n = 149; MDI, n = 144) between May 2011 and January 2015. Primary outcome data were available for 97% of participants (CSII, n = 143; MDI, n = 142). At 12 months, age-adjusted least mean squares HbA 1c concentrations were comparable between groups: CSII, 60.9 mmol/mol [95% confidence interval (CI) 58.5 to 63.3 mmol/mol]; MDI, 58.5 mmol/mol (95% CI 56.1 to 60.9 mmol/mol); and the difference of CSII – MDI, 2.4 mmol/mol (95% CI –0.4 to 5.3 mmol/mol). For HbA 1c concentrations of < 48 mmol/mol (CSII, 22/143 participants; MDI, 29/142 participants), the relative risk was 0.75 (95% CI 0.46 to 1.25), and for partial remission rates (CSII, 21/86 participants; MDI, 21/64), the relative risk was 0.74 (95% CI 0.45 to 1.24). The incidences of severe hypoglycaemia (CSII, 6/144; MDI, 2/149 participants) and DKA (CSII, 2/144 participants; MDI, 0/149 participants) were low. In total, 68 AEs (14 serious) were reported during CSII treatment and 25 AEs (eight serious) were reported during MDI treatment. Growth outcomes did not differ. The reported insulin use was higher with CSII (mean difference 0.1 unit/kg/day, 95% CI 0.0 to 0.2 unit/kg/day; p = 0.01). QoL was slightly higher for those randomised to CSII. From a NHS perspective, CSII was more expensive than MDI mean total cost (£1863, 95% CI £1620 to £2137) with no additional QALY gains (–0.006 QALYs, 95% CI –0.031 to 0.018 QALYs). Limitations: Generalisability beyond 12 months is uncertain. Conclusions: No clinical benefit of CSII over MDI was identified. CSII is not a cost-effective treatment in patients representative of the study population. Future work: Longer-term follow-up is required to determine if clinical outcomes diverge after 1 year. A qualitative exploration of patient and professional experiences of MDI and CSII should be considered. Trial registration: Current Controlled Trials ISRCTN29255275 and EudraCT 2010-023792-25. Funding: This project was funded by the National Institute for Health Research (NIHR) Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 22, No. 42. See the NIHR Journals Library website for further project information. The cost of insulin pumps and consumables supplied by F. Hoffman-La Roche AG (Basel, Switzerland) for the purpose of the study were subject to a 25% discount on standard NHS costs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3310/hta22420

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 36

Metadata

Authors
Blair, J., McKay, A., Ridyard, C., Thornborough, K., Bedson, E., Peak, M., Didi, M., Annan, F., Gregory, J. W., Hughes, D., & Gamble, C.
Venue
Health Technology Assessment
Published
2018-08
Volume
22
Issue
42
Pages
1-112
ISSN
  • 1366-5278 (ISSN-L)
  • 2046-4924
OpenAlex
W2885032144
Cited by
36
References
22
FWCI
2.22
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.