The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Present and future of gait assessment in clinical practice: Towards the application of novel trends and technologies
Open accessAbstract
Background: Despite being available for more than three decades, quantitative gait analysis remains largely associated with research institutions and not well leveraged in clinical settings. This is mostly due to the high cost/cumbersome equipment and complex protocols and data management/analysis associated with traditional gait labs, as well as the diverse training/experience and preference of clinical teams. Observational gait and qualitative scales continue to be predominantly used in clinics despite evidence of less efficacy of quantifying gait. Research objective: This study provides a scoping review of the status of clinical gait assessment, including shedding light on common gait pathologies, clinical parameters, indices, and scales. We also highlight novel state-of-the-art gait characterization and analysis approaches and the integration of commercially available wearable tools and technology and AI-driven computational platforms. Methods: A comprehensive literature search was conducted within PubMed, Web of Science, Medline, and ScienceDirect for all articles published until December 2021 using a set of keywords, including normal and pathological gait, gait parameters, gait assessment, gait analysis, wearable systems, inertial measurement units, accelerometer, gyroscope, magnetometer, insole sensors, electromyography sensors. Original articles that met the selection criteria were included. Results and significance: Clinical gait analysis remains highly observational and is hence subjective and largely influenced by the observer's background and experience. Quantitative Instrumented gait analysis (IGA) has the capability of providing clinicians with accurate and reliable gait data for diagnosis and monitoring but is limited in clinical applicability mainly due to logistics. Rapidly emerging smart wearable technology, multi-modality, and sensor fusion approaches, as well as AI-driven computational platforms are increasingly commanding greater attention in gait assessment. These tools promise a paradigm shift in the quantification of gait in the clinic and beyond. On the other hand, standardization of clinical protocols and ensuring their feasibility to map the complex features of human gait and represent them meaningfully remain critical challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Munn, Z., Peters, M. D. J., Stern, C., Tufanaru, C., McArthur, A., & Aromataris, E. (2018) · BMC Medical Research Methodology · doi:10.1186/s12874-018-0611-x · Cited by 11,385
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Multiple Sclerosis Severity Score: Using disability and disease duration to rate disease severity
Roxburgh, R. H. S. R., Seaman, S. R., Masterman, T., Hensiek, A. E., Sawcer, S. J., Vukusic, S., Achiti, I., Confavreux, C., Coustans, M., le Page, E., et al. (2005) · Neurology · doi:10.1212/01.wnl.0000156155.19270.f8 · Cited by 963
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Gait impairments in Parkinson’s disease
Mirelman, A., Bonato, P., Camicioli, R., Ellis, T. D., Giladi, N., Hamilton, J. L., Hass, C. J., Hausdorff, J. M., Pelosin, E., & Almeida, Q. J. (2019) · The Lancet Neurology · doi:10.1016/s1474-4422(19)30044-4 · Cited by 821
Foot Plantar Pressure Measurement System: A Review
Abdul Razak, A. H., Zayegh, A., Begg, R. K., & Wahab, Y. (2012) · Sensors · doi:10.3390/s120709884 · Cited by 817
Patterson, K. K., Gage, W. H., Brooks, D., Black, S. E., & McIlroy, W. E. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2009.10.014 · Cited by 740
Colyer, S. L., Evans, M., Cosker, D. P., & Salo, A. I. T. (2018) · Sports Medicine - Open · doi:10.1186/s40798-018-0139-y · Cited by 629
Gait analysis methods in rehabilitation
Baker, R. (2006) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-3-4 · Cited by 587
Rehabilitation of gait after stroke: a review towards a top-down approach
Belda-Lois, J.-M., Mena-del Horno, S., Bermejo-Bosch, I., Moreno, J. C., Pons, J. L., Farina, D., Iosa, M., Molinari, M., Tamburella, F., Ramos, A., et al. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-66 · Cited by 581
Fukuchi, C. A., Fukuchi, R. K., & Duarte, M. (2019) · Systematic Reviews · doi:10.1186/s13643-019-1063-z · Cited by 526
Neurological gait disorders in elderly people: clinical approach and classification
Snijders, A. H., van de Warrenburg, B. P., Giladi, N., & Bloem, B. R. (2007) · The Lancet Neurology · doi:10.1016/s1474-4422(06)70678-0 · Cited by 499
3D gait assessment in young and elderly subjects using foot-worn inertial sensors
Mariani, B., Hoskovec, C., Rochat, S., Büla, C., Penders, J., & Aminian, K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.07.003 · Cited by 370
Cappozzo, A. (1984) · Human Movement Science · doi:10.1016/0167-9457(84)90004-6 · Cited by 361
Clinical gait analysis: A review
Whittle, M. W. (1996) · Human Movement Science · doi:10.1016/0167-9457(96)00006-1 · Cited by 349
Noseworthy, J. H., Vandervoort, M. K., Wong, C. J., & Ebers, G. C. (1990) · Neurology · doi:10.1212/wnl.40.6.971 · Cited by 328
Gait parameters following stroke: a practical assessment.
von Schroeder, H. P., Coutts, R. D., Lyden, P. D., Billings, E., & Nickel, V. L. (1995) · PubMed · Cited by 317
Validity and Reliability of Wearable Sensors for Joint Angle Estimation: A Systematic Review
Poitras, I., Dupuis, F., Bielmann, M., Campeau-Lecours, A., Mercier, C., Bouyer, L., & Roy, J.-S. (2019) · Sensors · doi:10.3390/s19071555 · Cited by 309
Summary measures for clinical gait analysis: A literature review
Cimolin, V., & Galli, M. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.02.001 · Cited by 287
Estimation of Ground Reaction Forces and Moments During Gait Using Only Inertial Motion Capture
Karatsidis, A., Bellusci, G., Schepers, H., De Zee, M., Andersen, M., & Veltink, P. (2016) · Sensors · doi:10.3390/s17010075 · Cited by 287
Stagni, R., Fantozzi, S., Cappello, A., & Leardini, A. (2005) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2004.11.012 · Cited by 283
Smart Insole: A Wearable Sensor Device for Unobtrusive Gait Monitoring in Daily Life
Lin, F., Wang, A., Zhuang, Y., Tomita, M. R., & Xu, W. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2585643 · Cited by 265
Interrater Reliability of Videotaped Observational Gait-Analysis Assessments
Eastlack, M. E., Arvidson, J., Snyder-Mackler, L., Danoff, J. V., & McGarvey, C. L. (1991) · Physical Therapy · doi:10.1093/ptj/71.6.465 · Cited by 259
Gait analysis and clinical correlations in early Parkinson�s disease
Pistacchi, M. (2017) · Functional Neurology · doi:10.11138/fneur/2017.32.1.028 · Cited by 252
di Biase, L., Di Santo, A., Caminiti, M. L., De Liso, A., Shah, S. A., Ricci, L., & Di Lazzaro, V. (2020) · Sensors · doi:10.3390/s20123529 · Cited by 249
Gait performance of hemiparetic stroke patients: selected variables.
Rw, B. (1987) · PubMed · Cited by 242
McCamley, J., Donati, M., Grimpampi, E., & Mazzà, C. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.02.019 · Cited by 241
A Review on Accelerometry-Based Gait Analysis and Emerging Clinical Applications
Jarchi, D., Pope, J., Lee, T. K. M., Tamjidi, L., Mirzaei, A., & Sanei, S. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2018.2807182 · Cited by 224
Gait symmetry measures: A review of current and prospective methods
Vítečková, S., Kutílek, P., Svoboda, Z., Krupička, R., Kauler, J., & Szabo, Z. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2018.01.013 · Cited by 217
A Wireless Flexible Sensorized Insole for Gait Analysis
Crea, S., Donati, M., De Rossi, S., Oddo, C., & Vitiello, N. (2014) · Sensors · doi:10.3390/s140101073 · Cited by 216
Bugané, F., Benedetti, M. G., Casadio, G., Attala, S., Biagi, F., Manca, M., & Leardini, A. (2012) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2012.02.003 · Cited by 209
Patterson, K. K., Gage, W. H., Brooks, D., Black, S. E., & McIlroy, W. E. (2010) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968310372091 · Cited by 209
Role of machine learning in gait analysis: a review
Khera, P., & Kumar, N. (2020) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2020.1822940 · Cited by 187
Mohan, D. M., Khandoker, A. H., Wasti, S. A., Ismail Ibrahim Ismail Alali, S., Jelinek, H. F., & Khalaf, K. (2021) · Frontiers in Neurology · doi:10.3389/fneur.2021.650024 · Cited by 184
Self-citationA review of observational gait assessment in clinical practice
Toro, B., Nester, C., & Farren, P. C. (2003) · Physiotherapy Theory and Practice · doi:10.1080/09593980307964 · Cited by 180
Ewen, A. M., Stewart, S., St Clair Gibson, A., Kashyap, S. N., & Caplan, N. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.12.024 · Cited by 177
Franki, I., Desloovere, K., Cat, J. D., Feys, H., Molenaers, G., Calders, P., Vanderstraeten, G., Himpens, E., & Broeck, C. (2012) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-0983 · Cited by 173
Bahl, J. S., Nelson, M. J., Taylor, M., Solomon, L. B., Arnold, J. B., & Thewlis, D. (2018) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2018.02.897 · Cited by 171
Gait analysis in neurological populations: Progression in the use of wearables
Celik, Y., Stuart, S., Woo, W. L., & Godfrey, A. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.11.005 · Cited by 167
Diabetic Neuropathy and Gait: A Review
Alam, U., Riley, D. R., Jugdey, R. S., Azmi, S., Rajbhandari, S., D’Août, K., & Malik, R. A. (2017) · Diabetes Therapy · doi:10.1007/s13300-017-0295-y · Cited by 165
Aminian, K., Trevisan, C., Najafi, B., Dejnabadi, H., Frigo, C., Pavan, E., Telonio, A., Cerati, F., Marinoni, E. C., Robert, P., et al. (2004) · Gait & Posture · doi:10.1016/s0966-6362(03)00093-6 · Cited by 164
Clinical efficacy of instrumented gait analysis: Systematic review 2020 update
Wren, T. A. L., Tucker, C. A., Rethlefsen, S. A., Gorton, G. E., & Õunpuu, S. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.05.031 · Cited by 161
Saboor, A., Kask, T., Kuusik, A., Alam, M. M., Le Moullec, Y., Niazi, I. K., Zoha, A., & Ahmad, R. (2020) · IEEE Access · doi:10.1109/access.2020.3022818 · Cited by 158
Observation and analysis of hemiplegic gait: swing phase
Moore, S., Schurr, K., Wales, A., Moseley, A. M., & Herbert, R. (1993) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60487-6 · Cited by 150
Tools for Observational Gait Analysis in Patients With Stroke: A Systematic Review
Ferrarello, F., Bianchi, V. A. M., Baccini, M., Rubbieri, G., Mossello, E., Cavallini, M. C., Marchionni, N., & Bari, M. D. (2013) · Physical Therapy · doi:10.2522/ptj.20120344 · Cited by 145
Towards Inertial Sensor Based Mobile Gait Analysis: Event-Detection and Spatio-Temporal Parameters
Teufl, W., Lorenz, M., Miezal, M., Taetz, B., Fröhlich, M., & Bleser, G. (2018) · Sensors · doi:10.3390/s19010038 · Cited by 142
Utilization of wearable technology to assess gait and mobility post-stroke: a systematic review
Peters, D. M., O’Brien, E. S., Kamrud, K. E., Roberts, S. M., Rooney, T. A., Thibodeau, K. P., Balakrishnan, S., Gell, N., & Mohapatra, S. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00863-x · Cited by 133
Observation and analysis of hemiplegic gait: stance phase
Moseley, A. M., Wales, A., Herbert, R., Schurr, K., & Moore, S. (1993) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60486-4 · Cited by 115
Latorre, J., Colomer, C., Alcañíz, M., & Lloréns, R. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0568-y · Cited by 111
A Wearable Inertial Measurement Unit for Long-Term Monitoring in the Dependency Care Area
Rodríguez-Martín, D., Pérez‐López, C., Samà, A., Cabestany, J., & Catalá, A. (2013) · Sensors · doi:10.3390/s131014079 · Cited by 101
Effects of Knee Osteoarthritis on Hip and Ankle Gait Mechanics
Ro, D. H., Lee, J., Lee, J., Park, J., Han, H., & Lee, M. C. (2019) · Advances in Orthopedics · doi:10.1155/2019/9757369 · Cited by 98
A Clinically Interpretable Computer-Vision Based Method for Quantifying Gait in Parkinson’s Disease
Rupprechter, S., Morinan, G., Peng, Y., Foltynie, T., Sibley, K. G., Weil, R. S., Leyland, L., Baig, F., Morgante, F., Gilron, R., et al. (2021) · Sensors · doi:10.3390/s21165437 · Cited by 96
Gait Analysis for Poststroke Rehabilitation
Nadeau, S. M., Betschart, M., & Béthoux, F. (2013) · Physical Medicine and Rehabilitation Clinics of North America · doi:10.1016/j.pmr.2012.11.007 · Cited by 94
Development and validation of an accelerometer-based method for quantifying gait events
Boutaayamou, M., Schwartz, C., Stamatakis, J., Denoël, V., Maquet, D., Forthomme, B., Croisier, J., Macq, B. M. M., Verly, J., Garraux, G., et al. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.01.001 · Cited by 94
Lu, R., Xu, Y., Li, X., Fan, Y., Zeng, W., Tan, Y., Ren, K., Chen, W., & Cao, X. (2020) · Parkinson s Disease · doi:10.1155/2020/4693019 · Cited by 94
Rispens, S. M., Pijnappels, M. A. G. M., van Schooten, K. S., Beek, P. J., Daffertshofer, A., & van Dieën, J. H. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.182 · Cited by 93
The relative skin movement of the foot: a 2-D roentgen photogrammetry study
Tranberg, R., & Karlsson, D. (1998) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00052-1 · Cited by 88
Clinical scoring methods for multiple sclerosis
Noseworthy, J. H. (1994) · Annals of Neurology · doi:10.1002/ana.410360718 · Cited by 87
The effects of exercise on cognition and gait in Parkinson’s disease: A scoping review
Intzandt, B., Beck, E. N., & Silveira, C. R. A. (2018) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2018.09.018 · Cited by 87
Prajapati, S. K., Gage, W. H., Brooks, D., Black, S. E., & McIlroy, W. E. (2011) · Neurorehabilitation and Neural Repair · doi:10.1177/1545968310374189 · Cited by 86
Stability and Harmony of Gait in Patients with Subacute Stroke
Iosa, M., Bini, F., Marinozzi, F., Fusco, A., Morone, G., Koch, G., Cinnera, A. M., Bonnì, S., & Paolucci, S. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0178-0 · Cited by 75
Strazza, A., Mengarelli, A., Fioretti, S., Burattini, L., Agostini, V., Knaflitz, M., & Nardo, F. D. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.11.003 · Cited by 73
Data-driven gait analysis for diagnosis and severity rating of Parkinson’s disease
Balaji, E., Brindha, D., Elumalai, V. K., & Umesh, K. (2021) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2021.03.005 · Cited by 72
Byun, S., Han, J. W., Kim, T. H., & Kim, K. W. (2016) · PLoS ONE · doi:10.1371/journal.pone.0158956 · Cited by 69
Using swing resistance and assistance to improve gait symmetry in individuals post-stroke
Yen, S., Schmit, B. D., & Wu, M. (2015) · Human Movement Science · doi:10.1016/j.humov.2015.05.010 · Cited by 67
Application of wearable sensors for human gait analysis using fuzzy computational algorithm
Alaqtash, M., Yu, H., Brower, R. D., Abdelgawad, A. H. K., & Sarkodie-Gyan, T. (2011) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2011.04.010 · Cited by 65
Melese, H., Alamer, A., Temesgen, M. H., & Kahsay, G. (2020) · Diabetes Metabolic Syndrome and Obesity · doi:10.2147/dmso.s261175 · Cited by 61
Liu, K., INOUE, Y., SHIBATA, K., & Enguo, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2089454 · Cited by 60
Real-Time Gait Analysis Using a Single Head-Worn Inertial Measurement Unit
Hwang, T., Reh, J., Effenberg, A. O., & Blume, H. (2018) · IEEE Transactions on Consumer Electronics · doi:10.1109/tce.2018.2843289 · Cited by 59
Jagoš, H., Pils, K., Haller, M., Wassermann, C., Chhatwal, C., Rafolt, D., & Rattay, F. (2017) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2017.1320434 · Cited by 57
Gait Analysis for Post-Stroke Hemiparetic Patient by Multi-Features Fusion Method
Li, M., Tian, S., Sun, L., & Chen, X. (2019) · Sensors · doi:10.3390/s19071737 · Cited by 55
Roach, K. E., Wang, B., Kapron, A. L., Fiorentino, N. M., Saltzman, C. L., Foreman, K. B., & Anderson, A. E. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4034263 · Cited by 54
Schülein, S., Barth, J., Rampp, A., Rupprecht, R., Eskofier, B. M., Winkler, J., Gaßmann, K., & Klucken, J. (2017) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-017-0228-z · Cited by 54
Interlimb Coordination During the Stance Phase of Gait in Subjects With Stroke
Sousa, A. S. P., Silva, A., Santos, R. S., Sousa, F., & Tavares, J. M. R. S. (2013) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2013.06.032 · Cited by 53
Assessment of hemiplegic gait using the Wisconsin Gait Scale
Turani, N., Kemiksizoğlu, A., Karataş, M., & Özker, R. (2004) · Scandinavian Journal of Caring Sciences · doi:10.1111/j.1471-6712.2004.00262.x · Cited by 50
Leitch, K. M., Birmingham, T. B., Jones, I. C., Giffin, J. R., & Jenkyn, T. R. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.06.008 · Cited by 47
Acceleration Gait Measures as Proxies for Motor Skill of Walking: A Narrative Review
Dasgupta, P., VanSwearingen, J. M., Godfrey, A., Redfern, M., Montero‐Odasso, M., & Sejdić, E. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.3044260 · Cited by 46
Arafsha, F., Hanna, C., Aboualmagd, A., Fraser, S., & Saddik, A. E. (2018) · Journal of Sensor and Actuator Networks · doi:10.3390/jsan7030036 · Cited by 45
Gait disorder rehabilitation using vision and non-vision based sensors: A systematic review
Ali, A., Sundaraj, K., Ahmad, R. B., Ahamed, N. U., & Islam, M. A. (2012) · Bosnian Journal of Basic Medical Sciences · doi:10.17305/bjbms.2012.2484 · Cited by 43
Allseits, E., Kim, K. J., Bennett, C., GAILEY, R. S., GAUNAURD, I. A., & Agrawal, V. (2018) · Sensors · doi:10.3390/s18092759 · Cited by 43
Laudanski, A. F., Brouwer, B. J., & Li, Q. (2013) · Journal of Healthcare Engineering · doi:10.1260/2040-2295.4.4.555 · Cited by 39
Ihlen, E. A. F., Weiss, A., Beck, Y., et al. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.03.019 · Cited by 38
Nukala, B. T., Nakano, T., Rodriguez, A. I., Tsay, J., Lopez, J., Nguyen, T., Zupancic, S., & Lie, D. Y. C. (2016) · Biosensors · doi:10.3390/bios6040058 · Cited by 33
Assessment of Gait Symmetry and Gait Normality Using Inertial Sensors: In-Lab and In-Situ Evaluation
Sant’Anna, A., Wickström, N., Eklund, H., Zügner, R., & Tranberg, R. (2013) · Communications in computer and information science · doi:10.1007/978-3-642-38256-7_16 · Cited by 27
Butz, C., Iske, C., Truba, N. P., & Trott, K. (2019) · PubMed · Cited by 26
Toward a low-cost gait analysis system for clinical and free-living assessment
Ladha, C., Din, S. D., Nazarpour, K., et al. (2016) · doi:10.1109/embc.2016.7591086 · Cited by 21
Hsu, C., Tsai, Y., Yau, C.-S., Shie, H.-H., & Wu, C.-M. (2016) · Sensors · doi:10.3390/s16081156 · Cited by 21
Gait Training in Chronic Stroke Using Walk-Even Feedback Device: A Pilot Study
Krishnan, V., Khoo, I., Marayong, P., Demars, K., & Cormack, J. C. (2016) · Neuroscience Journal · doi:10.1155/2016/6808319 · Cited by 20
Hebda-Boon, A., Zhang, B., Amankwah, A., Shortland, A. P., & Morrissey, D. (2022) · Physical & Occupational Therapy In Pediatrics · doi:10.1080/01942638.2022.2037808 · Cited by 18
Ardalan, A., Yamane, N., Rao, A. K., Montes, J., & Goldman, S. (2021) · Health Informatics Journal · doi:10.1177/14604582211055650 · Cited by 9
Cited by
Deep Learning Approaches for Enhanced Lower-Limb Exoskeleton Control: A Review
Belal, M., Alsheikh, N., Aljarah, A., & Hussain, I. (2024) · IEEE Access · doi:10.1109/access.2024.3414175 · Cited by 42
Metadata
- Authors
- Hulleck, A. A., Menoth Mohan, D., Abdallah, N., El Rich, M., & Khalaf, K.
- Venue
- Frontiers in Medical Technology
- Publisher
- Frontiers Media SA
- Published
- 2022-12-16
- Volume
- 4
- Pages
- 901331-901331
- ISSN
- 2673-3129 (ISSN-L)
- OpenAlex
- W4313275909
- Cited by
- 281
- References
- 90
- FWCI
- 13.02
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.