Scalable and DiI-compatible optical clearance of the mammalian brain
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Efficient optical clearance is fundamental for whole brain imaging. In particular, clearance of the brain without membrane damage is required for the imaging of lipophilic tracer-labeled neural tracts. Relying on an ascending gradient of fructose solutions, SeeDB can achieve sufficient transparency of the mouse brain while ensuring that the plasma membrane remains intact. However, it is challenging to extend this method to larger mammalian brains due to the extremely high viscosity of the saturated fructose solution. Here we report a SeeDB-derived optical clearing method, termed FRUIT, which utilizes a cocktail of fructose and urea. As demonstrated in the adult mouse brain, combination of these two highly water-soluble clearing agents exerts a synergistic effect on clearance. More importantly, the final FRUIT solution has low viscosity so as to produce transparency of the whole adult rabbit brain via arterial perfusion, which is impossible to achieve with a saturated fructose solution. In addition to good compatibility with enhanced yellow fluorescent protein, the cocktail also preserves the fluorescence of the lipophilic tracer DiI. This work provides a volume-independent optical clearing method which retains the advantages of SeeDB, particularly compatibility with lipophilic tracers.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,468 · cited 3×
“The transmittance of the solutions exceeded the baseline in the band from 930 to 1000 nm, particularly at about 970 nm, because water itself substantially absorbs light at near-infrared wavelengths (Hale and Querry, 1973).”
BackgroundDeep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153 · cited 1×
“Because tissue opacity results mainly from the scattering of light which occurs when the refractive index (RI) of the scatter differs from that of the medium (Helmchen and Denk, 2005), optical clearing methods usually yield tissue transparency via RI matching.”
BackgroundA mesoscale connectome of the mouse brain
Oh, S. W., Harris, J. A., Ng, L., Winslow, B., Cain, N., Mihalas, S., Wang, Q., Lau, C., Kuan, L., Henry, A. M., et al. (2014) · Nature · doi:10.1038/nature13186 · Cited by 2,612 · cited 1×
“METHODS ARTICLE published: 24 February 2015 doi: 10.3389/fnana.2015.00019 Scalable and DiI-compatible optical clearance of the mammalian brain”
BackgroundInfluentialSelf-citationStructural and molecular interrogation of intact biological systems
Chung, K., Wallace, J., Kim, S.-Y., Kalyanasundaram, S., Andalman, A. S., Davidson, T. J., Mirzabekov, J. J., Zalocusky, K. A., Mattis, J., Denisin, A. K., et al. (2013) · Nature · doi:10.1038/nature12107 · Cited by 2,008 · cited 9×
“…cellular resolution information from unsectioned mammalian brains (Dodt et al., 2007; Hama et al., 2011; Becker et al., 2012; Erturk et al., 2012a; Chung et al., 2013; Ke et al., 2013; Kim et al., 2013; Kuwajima et al., 2013; Yushchenko and Schultz, 2013; Renier et al., 2014; Susaki et al., 2014;…”
BackgroundMethodInfluentialiDISCO: A Simple, Rapid Method to Immunolabel Large Tissue Samples for Volume Imaging
Renier, N., Wu, Z., Simon, D. J., Yang, J., Ariel, P., & Tessier-Lavigne, M. (2014) · Cell · doi:10.1016/j.cell.2014.10.010 · Cited by 1,818 · cited 3×
“…brains (Dodt et al., 2007; Hama et al., 2011; Becker et al., 2012; Erturk et al., 2012a; Chung et al., 2013; Ke et al., 2013; Kim et al., 2013; Kuwajima et al., 2013; Yushchenko and Schultz, 2013; Renier et al., 2014; Susaki et al., 2014; Tomer et al., 2014; Yang et al., 2014; Zhang et al., 2014).”
BackgroundMethodInfluentialWhole-Brain Imaging with Single-Cell Resolution Using Chemical Cocktails and Computational Analysis
Susaki, E. A., Tainaka, K., Perrin, D., Kishino, F., Tawara, T., Watanabe, T. M., Yokoyama, C., Onoe, H., Eguchi, M., Yamaguchi, S., et al. (2014) · Cell · doi:10.1016/j.cell.2014.03.042 · Cited by 1,325 · cited 3×
“…Hong-Wei Dong, University of Southern California, USA *Correspondence: Tianzi Jiang, Brainnetome Center, Institute of Automation, Chinese Academy of Sciences, 95 Zhong Guan Cun East Road, Hai Dian District, Beijing 100190, China e-mail: jiangtz@nlpr.ia.ac.cn †These authors have contributed…”
BackgroundInfluentialUltramicroscopy: three-dimensional visualization of neuronal networks in the whole mouse brain
Dodt, H.-U., Leischner, U., Schierloh, A., Jährling, N., Mauch, C. P., Deininger, K., Deussing, J. M., Eder, M., Zieglgänsberger, W., & Becker, K. (2007) · Nature Methods · doi:10.1038/nmeth1036 · Cited by 1,238 · cited 9×
“METHODS ARTICLE published: 24 February 2015 doi: 10.3389/fnana.2015.00019 Scalable and DiI-compatible optical clearance of the mammalian brain”
BackgroundMethodInfluentialScale: a chemical approach for fluorescence imaging and reconstruction of transparent mouse brain
Hama, H., Kurokawa, H., Kawano, H., Ando, R., Shimogori, T., Noda, H., Fukami, K., Sakaue-Sawano, A., & Miyawaki, A. (2011) · Nature Neuroscience · doi:10.1038/nn.2928 · Cited by 1,142 · cited 20×
“Keywords: optical tissue clearing, SeeDB, Urea, tract tracing, whole brain imaging, CLARITY, CUBIC, 3DISCO”
BackgroundMethodResultInfluentialThree-dimensional imaging of solvent-cleared organs using 3DISCO
Ertürk, A., Becker, K., Jährling, N., Mauch, C. P., Hojer, C. D., Egen, J. G., Hellal, F., Bradke, F., Sheng, M., & Dodt, H.-U. (2012) · Nature Protocols · doi:10.1038/nprot.2012.119 · Cited by 992 · cited 10×
“METHODS ARTICLE published: 24 February 2015 doi: 10.3389/fnana.2015.00019 Scalable and DiI-compatible optical clearance of the mammalian brain”
BackgroundMethodInfluentialSingle-Cell Phenotyping within Transparent Intact Tissue through Whole-Body Clearing
Yang, B., Treweek, J. B., Kulkarni, R. P., Deverman, B. E., Chen, C.-K., Lubeck, E., Shah, S., Cai, L., & Gradinaru, V. (2014) · Cell · doi:10.1016/j.cell.2014.07.017 · Cited by 925 · cited 14×
“However, SeeDB and our method would not facilitate immunostaining of the whole brain (Chung et al., 2013; Renier et al., 2014; Susaki et al., 2014; Tainaka et al., 2014; Yang et al., 2014), because they are not intentionally designed to remove lipids which render tissue poorly accessible to molecular probes, such as a…”
BackgroundMethodInfluential
Cited by
Richardson, D. S., & Lichtman, J. W. (2015) · Cell · doi:10.1016/j.cell.2015.06.067 · Cited by 1,095
“Two lower-cost options are TDE and the FRUIT technique.”
InfluentialAdvanced CUBIC protocols for whole-brain and whole-body clearing and imaging
Susaki, E. A., Tainaka, K., Perrin, D., Yukinaga, H., Kuno, A., & Ueda, H. R. (2015) · Nature Protocols · doi:10.1038/nprot.2015.085 · Cited by 810
Tissue clearing and its applications in neuroscience
Ueda, H. R., Ertürk, A., Chung, K., Gradinaru, V., Chédotal, A., Tomancak, P., & Keller, P. J. (2020) · Nature Reviews Neuroscience · doi:10.1038/s41583-019-0250-1 · Cited by 609
ScaleS: an optical clearing palette for biological imaging
Hama, H., Hioki, H., Namiki, K., Hoshida, T., Kurokawa, H., Ishidate, F., Kaneko, T., Akagi, T., Saito, T., Saido, T., et al. (2015) · Nature Neuroscience · doi:10.1038/nn.4107 · Cited by 603
Chemical Landscape for Tissue Clearing Based on Hydrophilic Reagents
Tainaka, K., Murakami, T. C., Susaki, E. A., Shimizu, C., Saito, R., Takahashi, K., Hayashi-Takagi, A., Sekiya, H., Arima, Y., Nojima, S., et al. (2018) · Cell Reports · doi:10.1016/j.celrep.2018.07.056 · Cited by 337
Spatiotemporal single-cell analysis of gene expression in the mouse suprachiasmatic nucleus
Wen, S., Ma, D., Zhao, M., Xie, L., Wu, Q., Gou, L., Zhu, C., Fan, Y., Wang, H., & Yan, J. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-0586-x · Cited by 328
Susaki, E. A., & Ueda, H. R. (2016) · Cell Chemical Biology · doi:10.1016/j.chembiol.2015.11.009 · Cited by 295
Chemical Principles in Tissue Clearing and Staining Protocols for Whole-Body Cell Profiling
Tainaka, K., Kuno, A., Kubota, S. I., Murakami, T., & Ueda, H. R. (2016) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev-cellbio-111315-125001 · Cited by 277
Treweek, J. B., Chan, K. Y., Flytzanis, N. C., Yang, B., Deverman, B. E., Greenbaum, A., Lignell, A., Xiao, C., Cai, L., Ladinsky, M. S., et al. (2015) · Nature Protocols · doi:10.1038/nprot.2015.122 · Cited by 258
Whole-Brain Profiling of Cells and Circuits in Mammals by Tissue Clearing and Light-Sheet Microscopy
Ueda, H. R., Dodt, H.-U., Osten, P., Economo, M. N., Chandrashekar, J., & Keller, P. J. (2020) · Neuron · doi:10.1016/j.neuron.2020.03.004 · Cited by 213
In-vivo and ex-vivo optical clearing methods for biological tissues: review
Costantini, I., Cicchi, R., Silvestri, L., Vanzi, F., & Pavone, F. S. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.005251 · Cited by 207
Modeling glioblastoma invasion using human brain organoids and single-cell transcriptomics
Krieger, T. G., Tirier, S. M., Park, J., Jechow, K., Eisemann, T., Peterziel, H., Angel, P., Eils, R., & Conrad, C. (2020) · Neuro-Oncology · doi:10.1093/neuonc/noaa091 · Cited by 181
Rios, A. C., Capaldo, B. D., Vaillant, F., Pal, B., van Ineveld, R., Dawson, C. A., Chen, Y., Nolan, E., Fu, N. Y., Jackling, F. C., et al. (2019) · Cancer Cell · doi:10.1016/j.ccell.2019.02.010 · Cited by 168
Routine Optical Clearing of 3D-Cell Cultures: Simplicity Forward
Nürnberg, E., Vitacolonna, M., Klicks, J., von Molitor, E., Cesetti, T., Keller, F., Bruch, R., Ertongur-Fauth, T., Riedel, K., Scholz, P., et al. (2020) · Frontiers in Molecular Biosciences · doi:10.3389/fmolb.2020.00020 · Cited by 93
Mayorca-Guiliani, A. E., Willacy, O., Madsen, C. D., Rafaeva, M., Elisabeth Heumüller, S., Bock, F., Sengle, G., Koch, M., Imhof, T., Zaucke, F., et al. (2019) · Nature Protocols · doi:10.1038/s41596-019-0225-8 · Cited by 79
Metadata
- Authors
- Hou, B., Zhang, D., Zhao, S., Wei, M., Yang, Z., Wang, S., Wang, J., Zhang, X., Liu, B., Fan, L., Li, Y., Qiu, Z., Zhang, C., & Jiang, T.
- Venue
- Frontiers in Neuroanatomy
- Publisher
- Frontiers Media SA
- Published
- 2015-02-24
- Volume
- 9
- Pages
- 19-19
- ISSN
- 1662-5129 (ISSN-L)
- OpenAlex
- W1972702281
- Cited by
- 171
- References
- 24
- FWCI
- 8.47
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.