P300 brain computer interface: current challenges and emerging trends
Open accessAbstract
A brain-computer interface (BCI) enables communication without movement based on brain signals measured with electroencephalography (EEG). BCIs usually rely on one of three types of signals: the P300 and other components of the event-related potential (ERP), steady state visual evoked potential (SSVEP), or event related desynchronization (ERD). Although P300 BCIs were introduced over twenty years ago, the past few years have seen a strong increase in P300 BCI research. This closed-loop BCI approach relies on the P300 and other components of the ERP, based on an oddball paradigm presented to the subject. In this paper, we overview the current status of P300 BCI technology, and then discuss new directions: paradigms for eliciting P300s; signal processing methods; applications; and hybrid BCIs. We conclude that P300 BCIs are quite promising, as several emerging directions have not yet been fully explored and could lead to improvements in bit rate, reliability, usability, and flexibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Is the P300 component a manifestation of context updating?
Donchin, E., & Coles, M. G. H. (1988) · Behavioral and Brain Sciences · doi:10.1017/s0140525x00058027 · Cited by 3,585
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Temporary suppression of visual processing in an RSVP task: An attentional blink?
Raymond, J. E., Shapiro, K. L., & Arnell, K. M. (1992) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037//0096-1523.18.3.849 · Cited by 2,260
Motor imagery and direct brain-computer communication
Pfurtscheller, G., & Neuper, C. (2001) · Proceedings of the IEEE · doi:10.1109/5.939829 · Cited by 1,990
Donchin, E. (1981) · Psychophysiology · doi:10.1111/j.1469-8986.1981.tb01815.x · Cited by 1,848
Temporary suppression of visual processing in an RSVP task: an attentional blink?
Raymond, J. E., Shapiro, K. L., & Arnell, K. M. (1992) · Journal of Experimental Psychology: Human Perception and Performance · doi:10.1037/0096-1523.18.3.849 · Cited by 1,649
The mental prosthesis: assessing the speed of a P300-based brain-computer interface
Donchin, E., Spencer, K. M., & Wijesinghe, R. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847808 · Cited by 1,222
Herrmann, C. S. (2001) · Experimental Brain Research · doi:10.1007/s002210100682 · Cited by 1,080
Bin, G., Gao, X., Yan, Z., Hong, B., & Gao, S. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046002 · Cited by 773
A comparison of classification techniques for the P300 Speller
Krusienski, D. J., Sellers, E. W., Cabestaing, F., Bayoudh, S., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/007 · Cited by 762
Self-citationInformation Delivery and the Sensory Evoked Potential
Sutton, S., Tueting, P., Zubin, J., & John, E. R. (1967) · Science · doi:10.1126/science.155.3768.1436 · Cited by 696
Repetition blindness: Type recognition without token individuation
Kanwisher, N. G. (1987) · Cognition · doi:10.1016/0010-0277(87)90016-3 · Cited by 664
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
Self-citationEimer, M. (2000) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00285-0 · Cited by 635
A P300-based brain–computer interface for people with amyotrophic lateral sclerosis
Nijboer, F., Sellers, E. W., Mellinger, J., Jordan, M. A., Matuz, T., Furdea, A., Halder, S., Mochty, U., Krusienski, D. J., Vaughan, T. M., et al. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2008.03.034 · Cited by 633 · cited 1×
“The BP and Intendix systems described above were validated with ALS users in their home settings, as were other P300 BCI systems (Sellers et al., 2006, 2010; Vaughan et al., 2006; Nijboer et al., 2008).”
MethodSelf-citationPfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570 · cited 5×
“Several human perceptual phenomena such as attentional blink, repetition blindness, and habituation are potential sources of error in P300 detection and have been addressed in the literature (Fazel-Rezai, 2007, 2009; Citi et al., 2008; Jin et al., 2010; Townsend et al., 2010).”
BackgroundMethodResultInfluentialSelf-citationHow many people are able to operate an EEG-based brain-computer interface (BCI)?
Guger, C., Edlinger, G., Harkam, W., Niedermayer, I., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814481 · Cited by 526
Self-citationIturrate, I., Antelis, J. M., Kubler, A., & Minguez, J. (2009) · IEEE Transactions on Robotics · doi:10.1109/tro.2009.2020347 · Cited by 512
Sellers, E. W., Krusienski, D. J., McFarland, D. J., Vaughan, T. M., & Wolpaw, J. R. (2006) · Biological Psychology · doi:10.1016/j.biopsycho.2006.04.007 · Cited by 501
Self-citationThe thought translation device (TTD) for completely paralyzed patients
Birbaumer, N., Kubler, A., Ghanayim, N., Hinterberger, T., Perelmouter, J., Kaiser, J., Iversen, I., Kotchoubey, B., Neumann, N., & Flor, H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847812 · Cited by 493
An improved P300-based brain-computer interface
Serby, H., Yom-Tov, E., & Inbar, G. F. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.841878 · Cited by 403
A brain-computer interface for long-term independent home use
Sellers, E. W., Vaughan, T. M., & Wolpaw, J. R. (2010) · Amyotrophic Lateral Sclerosis · doi:10.3109/17482961003777470 · Cited by 400
Self-citationControl of a humanoid robot by a noninvasive brain–computer interface in humans
Bell, C. J., Shenoy, P., Chalodhorn, R., & Rao, R. P. N. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/2/012 · Cited by 387
(C)overt attention and visual speller design in an ERP-based brain-computer interface
Treder, M. S., & Blankertz, B. (2010) · Behavioral and Brain Functions · doi:10.1186/1744-9081-6-28 · Cited by 362
The wadsworth BCI research and development program: at home with BCI
Vaughan, T. M., McFarland, D. J., Schalk, G., Sarnacki, W. A., Krusienski, D. J., Sellers, E. W., & Wolpaw, J. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875577 · Cited by 334
Self-citationTowards an independent brain–computer interface using steady state visual evoked potentials
Allison, B. Z., McFarland, D. J., Schalk, G., Zheng, S. D., Jackson, M. M., & Wolpaw, J. R. (2008) · Clinical Neurophysiology · doi:10.1016/j.clinph.2007.09.121 · Cited by 327
Self-citationPiccione, F., Giorgi, F., Tonin, P., Priftis, K., Giove, S., Silvoni, S., Palmas, G., & Beverina, F. (2006) · Clinical Neurophysiology · doi:10.1016/j.clinph.2005.07.024 · Cited by 325
A high-speed BCI based on code modulation VEP
Bin, G., Gao, X., Wang, Y., Li, Y., Hong, B., & Gao, S. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025015 · Cited by 305
Kübler, A., Furdea, A., Halder, S., Hammer, E. M., Nijboer, F., & Kotchoubey, B. (2009) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2008.04122.x · Cited by 303
Self-citationFlashing characters with famous faces improves ERP-based brain–computer interface performance
Kaufmann, T., Schulz, S. M., Grünzinger, C., & Kübler, A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/5/056016 · Cited by 300
Self-citationA Comprehensive Survey of Brain Interface Technology Designs
Mason, S. G., Bashashati, A., Fatourechi, M., Navarro, K. F., & Birch, G. E. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9170-0 · Cited by 299
An EEG-Based BCI System for 2-D Cursor Control by Combining Mu/Beta Rhythm and P300 Potential
Li, Y., Long, J., Yu, T., Yu, Z., Wang, C., Zhang, H., & Guan, C. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055564 · Cited by 298
Toward a hybrid brain–computer interface based on imagined movement and visual attention
Allison, B. Z., Brunner, C., Kaiser, V, Müller-Putz, G. R., Neuper, C., & Pfurtscheller, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026007 · Cited by 291
Self-citationDoes the ‘P300’ speller depend on eye gaze?
Brunner, P., Joshi, S., Briskin, S., Wolpaw, J. R., Bischof, H., & Schalk, G. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056013 · Cited by 291
P300 amplitude is determined by target‐to‐target interval
Gonsalvez, C. J., & Polich, J. (2002) · Psychophysiology · doi:10.1017/s0048577201393137 · Cited by 279
A tactile P300 brain-computer interface
Brouwer (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00019 · Cited by 278
Robust classification of EEG signal for brain-computer interface
Thulasidas, M., Guan, C., & Wu, J. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.862695 · Cited by 261
Motivation modulates the P300 amplitude during brain–computer interface use
Kleih, S. C., Nijboer, F., Halder, S., & Kübler, A. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.034 · Cited by 258
Self-citationXu, N., Gao, X., Hong, B., Miao, X., Gao, S., & Yang, F. (2004) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2004.826699 · Cited by 258
ERPs evoked by different matrix sizes: implications for a brain computer interface (BCI) system
Allison, B. Z., & Pineda, J. A. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814448 · Cited by 225
Self-citationWorkload assessment of computer gaming using a single-stimulus event-related potential paradigm
Allison, B. Z., & Polich, J. (2008) · Biological Psychology · doi:10.1016/j.biopsycho.2007.10.014 · Cited by 203
Self-citationAn Asynchronous P300 BCI With SSVEP-Based Control State Detection
Panicker, R. C., Puthusserypady, S., & Sun, Y. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2116018 · Cited by 203
Visual modifications on the P300 speller BCI paradigm
Salvaris, M., & Sepulveda, F. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/4/046011 · Cited by 197
N200-speller using motion-onset visual response
Hong, B., Guo, F., Liu, T., Gao, X., & Gao, S. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.06.026 · Cited by 192
Comparison of Dry and Gel Based Electrodes for P300 Brain–Computer Interfaces
Guger, C., Krausz, G., Allison, B. Z., & Edlinger, G. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00060 · Cited by 190
Self-citationMünßinger, J. I., Halder, S., Kleih, S. C., Furdea, A., Raco, V., Hösle, A., & Kübler, A. (2010) · Frontiers in Neuroscience · doi:10.3389/fnins.2010.00182 · Cited by 175
Self-citationToward a high-throughput auditory P300-based brain–computer interface
Klobassa, D. S., Vaughan, T. M., Brunner, P., Schwartz, N. E., Wolpaw, J. R., Neuper, C., & Sellers, E. W. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.04.019 · Cited by 165
Self-citationA brain–computer interface using motion-onset visual evoked potential
Guo, F., Hong, B., Gao, X., & Gao, S. (2008) · Journal of Neural Engineering · doi:10.1088/1741-2560/5/4/011 · Cited by 163
A virtual reality testbed for brain-computer interface research
Bayliss, J. D., & Ballard, D. H. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847811 · Cited by 161
A Brain-Computer Interface as Input Channel for a Standard Assistive Technology Software
Zickler, C., Riccio, A., Leotta, F., Hillian-Tress, S., Halder, S., Holz, E. M., Staiger-Sälzer, P., Hoogerwerf, E.-J., Desideri, L., Mattia, D., et al. (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200409 · Cited by 159
Self-citationPredictive Spelling With a P300-Based Brain–Computer Interface: Increasing the Rate of Communication
Ryan, D. B., Frye, G. E., Townsend, G., Berry, D. R., Mesa-G, S., Gates, N. A., & Sellers, E. W. (2010) · International Journal of Human-Computer Interaction · doi:10.1080/10447318.2011.535754 · Cited by 155
Self-citationP300-Based BCI Mouse With Genetically-Optimized Analogue Control
Citi, L., Poli, R., Cinel, C., & Sepulveda, F. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.913184 · Cited by 153
The neurochip BCI: towards a neural prosthesis for upper limb function
Jackson, A., Moritz, C. T., Mavoori, J., Lucas, T. H., & Fetz, E. E. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875547 · Cited by 139
The Eriksen flanker effect revisited
Sanders, A. F., & Lamers, J. M. (2002) · Acta Psychologica · doi:10.1016/s0001-6918(01)00048-8 · Cited by 134
Allison, B. Z., & Pineda, J. A. (2005) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2005.02.007 · Cited by 123
Self-citationMartens, S., Hill, N. J., Farquhar, J. D. R., & Schölkopf, B. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026003 · Cited by 115
Toward smarter BCIs: extending BCIs through hybridization and intelligent control
Allison, B. Z., Leeb, R., Brunner, C., Müller-Putz, G., Bauernfeind, G., Kelly, J. W., & Neuper, C. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/1/013001 · Cited by 112
Self-citationA region-based P300 speller for brain-computer interface
Fazel-Rezai, R., & Abhari, K. (2009) · Canadian Journal of Electrical and Computer Engineering · doi:10.1109/cjece.2009.5443854 · Cited by 101
Self-citationJin, J., Allison, B. Z., Wang, X., & Neuper, C. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.01.004 · Cited by 97
Self-citationAn online brain–computer interface using non-flashing visual evoked potentials
Liu, T., Goldberg, L., Gao, S., & Hong, B. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/3/036003 · Cited by 96
Human Error in P300 Speller Paradigm for Brain-Computer Interface
Fazel-Rezai, R. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4352840 · Cited by 95
Self-citationOut of the frying pan into the fire—the P300-based BCI faces real-world challenges
Kleih, S. C., Kaufmann, T., Zickler, C., Halder, S., Leotta, F., Cincotti, F., Aloise, F., Riccio, A., Herbert, C., Mattia, D., et al. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00019-4 · Cited by 94
Self-citationLakey, C. E., Berry, D. R., & Sellers, E. W. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025019 · Cited by 88
Self-citationA Hybrid Brain-Computer Interface for Smart Home Control
Edlinger, G., Holzner, C., & Guger, C. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21605-3_46 · Cited by 73
Self-citationA new P300 stimulus presentation pattern for EEG-based spelling systems
Jin, J., Horki, P., Brunner, C., Wang, X., Neuper, C., & Pfurtscheller, G. (2010) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.029 · Cited by 65
A hybrid brain-computer interface control strategy in a virtual environment
Su, Y., Qi, Y., Luo, J., Wu, B., Yang, F., Yi, L., Zhuang, Y., Zheng, X., & Chen, W. (2011) · Frontiers of Information Technology & Electronic Engineering · doi:10.1631/jzus.c1000208 · Cited by 55
Fazel-Rezai, R., & Abhari, K. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649364 · Cited by 48
Self-citationAnalysis of P300 Classifiers in Brain Computer Interface Speller
Mirghasemi, H., Fazel-Rezai, R., & Shamsollahi, M. B. (2006) · Conference proceedings · doi:10.1109/iembs.2006.259521 · Cited by 43
Self-citationAllison, B. Z. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02577-8_61 · Cited by 41
Self-citationP300-based Brain-Computer Interface Paradigm Design
Fazel-Rezai, R., & Ahm, W. (2011) · InTech eBooks · doi:10.5772/14858 · Cited by 37
Self-citationGoal-Oriented Control with Brain-Computer Interface
Edlinger, G., Holzner, C., Groenegress, C., Guger, C., & Slater, M. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02812-0_83 · Cited by 35
Self-citationA Comparison among Several P300 Brain-Computer Interface Speller Paradigms
Fazel-Rezai, R., Gavett, S., Ahmad, W., Rabbi, A. F., & Schneider, E. (2011) · Clinical EEG and Neuroscience · doi:10.1177/155005941104200404 · Cited by 21
Self-citationEdlinger, G., & Guger, C. (2011) · Lecture notes in computer science · doi:10.1007/978-3-642-21663-3_59 · Cited by 16
Self-citationAsynchronous P300 Bci: Ssvep-Based Control State Detection
Panicker, R. C., Puthusserypady, S. K., & Sun, Y. (2010) · National University of Singapore · doi:10.5281/zenodo.42093 · Cited by 9
Cited by
EEGNet: A Compact Convolutional Network for EEG-based Brain-Computer Interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2016) · arXiv · doi:10.48550/arxiv.1611.08024 · Cited by 5,105
EEGNet: a compact convolutional neural network for EEG-based brain-computer interfaces
Lawhern, V. J., Solon, A. J., Waytowich, N. R., Gordon, S. M., Hung, C. P., & Lance, B. J. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aace8c · Cited by 5,115
“They are generally robust across subjects and contain well-stereotyped waveforms, enabling the exact time course of the ERP to be modeled through machine learning efficiently [40].”
BackgroundA comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
Visual and Auditory Brain–Computer Interfaces
Gao, S., Wang, Y., Gao, X., & Hong, B. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2300164 · Cited by 449
Metadata
- Authors
- Fazel-Rezai, R., Allison, B. Z., Guger, C., Sellers, E. W., Kleih, S. C., & Kübler, A.
- Venue
- Frontiers in Neuroengineering
- Publisher
- Frontiers Media SA
- Published
- 2012
- Volume
- 5
- Pages
- 14-14
- ISSN
- 1662-6443 (ISSN-L)
- OpenAlex
- W2105438329
- Cited by
- 359
- References
- 76
- FWCI
- 9.21
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.