CoChat

2.5D and 3D segmentation of brain metastases with deep learning on multinational MRI data

Open access

The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.

Abstract

Introduction: Management of patients with brain metastases is often based on manual lesion detection and segmentation by an expert reader. This is a time- and labor-intensive process, and to that end, this work proposes an end-to-end deep learning segmentation network for a varying number of available MRI available sequences. Methods: We adapt and evaluate a 2.5D and a 3D convolution neural network trained and tested on a retrospective multinational study from two independent centers, in addition, nnU-Net was adapted as a comparative benchmark. Segmentation and detection performance was evaluated by: (1) the dice similarity coefficient, (2) a per-metastases and the average detection sensitivity, and (3) the number of false positives. Results: The 2.5D and 3D models achieved similar results, albeit the 2.5D model had better detection rate, whereas the 3D model had fewer false positive predictions, and nnU-Net had fewest false positives, but with the lowest detection rate. On MRI data from center 1, the 2.5D, 3D, and nnU-Net detected 79%, 71%, and 65% of all metastases; had an average per patient sensitivity of 0.88, 0.84, and 0.76; and had on average 6.2, 3.2, and 1.7 false positive predictions per patient, respectively. For center 2, the 2.5D, 3D, and nnU-Net detected 88%, 86%, and 78% of all metastases; had an average per patient sensitivity of 0.92, 0.91, and 0.85; and had on average 1.0, 0.4, and 0.1 false positive predictions per patient, respectively. Discussion/Conclusion: Our results show that deep learning can yield highly accurate segmentations of brain metastases with few false positives in multinational data, but the accuracy degrades for metastases with an area smaller than 0.4 cm 2.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fninf.2022.1056068

Cites

47 of 47 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Two patient cohorts from different institutions (A and B) were annotated by working radiologists, coregistered, and brain extracted. Cohort A was divided into a training/validation set and a test set, whilst cohort B was kept as an independent test set. Three models were trained on the training set from cohort A, and evaluated on the test set from cohort A and cohort B. Two of the models were trained with input-level dropout to allow for a variable number of input MR sequences.
Figure 1 Two patient cohorts from different institutions (A and B) were annotated by working radiologists, coregistered, and brain extracted. Cohort A was divided into a training/validation set and a test set, whilst cohort B was kept as an independent test set. Three models were trained on the training set from cohort A, and evaluated on the test set from cohort A and cohort B. Two of the models were trained with input-level dropout to allow for a variable number of input MR sequences.CC BY · PubMed Central
Figure 2 The general model architecture that takes either five slices from one to four sequences as inputs for the 2.5D model or a volume from one to four sequences for the 3D model. For the 2.5D model, the inputs are upscaled with bilinear upscaling before downsampling through a convolutional operation. The model prediction is a probability map between 0 and 1.
Figure 2 The general model architecture that takes either five slices from one to four sequences as inputs for the 2.5D model or a volume from one to four sequences for the 3D model. For the 2.5D model, the inputs are upscaled with bilinear upscaling before downsampling through a convolutional operation. The model prediction is a probability map between 0 and 1.CC BY · PubMed Central
Figure 3 Histogram plots of the number of correctly predicted metastases and the number of missed metastases as a function of the maximum metastatic area in the axial plane and metastatic volume for the Stanford patient test cohort for all three models tested. Metastases larger than 120 (area) or 500 (volume) voxels were excluded to improve readability. TP denote true positive metastases, i.e., correctly predicted metastases, and TN denotes true negative metastases, i.e., not predicted metastases.
Figure 3 Histogram plots of the number of correctly predicted metastases and the number of missed metastases as a function of the maximum metastatic area in the axial plane and metastatic volume for the Stanford patient test cohort for all three models tested. Metastases larger than 120 (area) or 500 (volume) voxels were excluded to improve readability. TP denote true positive metastases, i.e., correctly predicted metastases, and TN denotes true negative metastases, i.e., not predicted metastases.CC BY · PubMed Central
Figure 4 Histogram plots of the number of correctly predicted metastases and the number of missed metastases as a function of the maximum metastatic area in the axial plane and metastatic volume for the OUH cohort for all three models tested. Metastases larger than 120 (area) or 500 (volume) voxels were excluded to improve readability. TP denote true positive metastases, i.e., correctly predicted metastases, and TN denotes true negative metastases, i.e., not predicted metastases.
Figure 4 Histogram plots of the number of correctly predicted metastases and the number of missed metastases as a function of the maximum metastatic area in the axial plane and metastatic volume for the OUH cohort for all three models tested. Metastases larger than 120 (area) or 500 (volume) voxels were excluded to improve readability. TP denote true positive metastases, i.e., correctly predicted metastases, and TN denotes true negative metastases, i.e., not predicted metastases.CC BY · PubMed Central
Figure 5 Violin plot of the number of false positives per patient for the Stanford and OUH cohorts for the 2.5D, 3D, and nnU-Net. Patients with more than 10 false positives were excluded to improve readability. This accounts to five patients in the Stanford cohort and zero patients in the OUH cohort. The median number of false positives were either 2, 1, or 0 in the Stanford cohort and 1 or 0 in the OUH cohort.
Figure 5 Violin plot of the number of false positives per patient for the Stanford and OUH cohorts for the 2.5D, 3D, and nnU-Net. Patients with more than 10 false positives were excluded to improve readability. This accounts to five patients in the Stanford cohort and zero patients in the OUH cohort. The median number of false positives were either 2, 1, or 0 in the Stanford cohort and 1 or 0 in the OUH cohort.CC BY · PubMed Central
Figure 6 Visualization of segmentation examples from the Stanford cohort with the ground truth annotation (red regions of interests) and the segmentation probability map from the 2.5D network. The (bottom right) image slice belongs to the patient with 153 metastases and is one of the worst cases from the test set.
Figure 6 Visualization of segmentation examples from the Stanford cohort with the ground truth annotation (red regions of interests) and the segmentation probability map from the 2.5D network. The (bottom right) image slice belongs to the patient with 153 metastases and is one of the worst cases from the test set.CC BY · PubMed Central
Figure 7 Visualization of segmentation examples from the OUH cohort with the ground truth annotation (red regions of interests) and the segmentation probability map from the 2.5D network.
Figure 7 Visualization of segmentation examples from the OUH cohort with the ground truth annotation (red regions of interests) and the segmentation probability map from the 2.5D network.CC BY · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 4

  1. Consortium M. (2022). MONAI: Medical Open Network for AI.
  2. CordtsM. OmranM. RamosS. RehfeldT. EnzweilerM. BenensonR. The Cityscapes Dataset for Semantic Urban Scene Understanding,” in Proceedings of the IEEE conference on computer vision and pattern recognition, 3213–32232016
  3. Milletari F. Navab N. Ahmadi S. A. (2016). V-Net: Fully convolutional neural networks for volumetric medical image segmentation. Proc - 2016 4th Int Conf 3D Vision, 3DV 2016 565– 571. Available online at: https://arxiv.org/abs/1606.04797 (accessed on June 15, 2016). · arXiv
  4. Redmon J. Divvala S. Girshick R. Farhadi A. (2016). You Only Look Once: Unified, Real-Time Object Detection. 779– 788. Available online at: https://ieeexplore.ieee.org/document/7780460 (accessed on June 27–30, 2016).

Cited by

See all 36

Metadata

Authors
Ottesen, J. A., Yi, D., Tong, E., Iv, M., Latysheva, A., Saxhaug, C., Jacobsen, K. D., Helland, Å., Emblem, K. E., Rubin, D. L., Bjørnerud, A., Zaharchuk, G., & Grøvik, E.
Affiliations
  • University of Illinois Chicago (US)
  • Stanford University (US)
  • Oslo University Hospital (NO)
  • Norwegian University of Science and Technology (NO)
Venue
Frontiers in Neuroinformatics
Published
2023-01-18
Volume
16
Pages
1056068-1056068
ISSN
1662-5196 (ISSN-L)
OpenAlex
W4317395573
Cited by
32
References
42
Citations by year
2026: 6 · 2025: 11 · 2024: 9 · 2023: 5
FWCI
3.20
Type
journal article
Language
en
Open access
Locations
  • Frontiers in Neuroinformatics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • NORA - Norwegian Open Research Archives (submittedVersion, cc-by)
Funders
Helse Sør-Øst RHF
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Brain Tumor Detection and Classification
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Medical Image Segmentation Techniques
  • Health Sciences › Medicine › Oncology › Brain Metastases and Treatment
Keywords
brain metastases, lesion segmentation, 3D convolutional neural networks, magnetic resonance imaging, nnU-Net, lesion detection, false positives, detection sensitivity, cross-center validation, deep learning

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.