Automatic real-time monitoring and assessment of tremor parameters in the upper limb from orientation data
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Upper limb tremor is the most prevalent movement disorder and, unfortunately, it is not effectively managed in a large proportion of the patients. Neuroprostheses that stimulate the sensorimotor pathways are one of the most promising alternatives although they are still under development. To enrich the interpretation of data recorded during long-term tremor monitoring and to increase the intelligence of tremor suppression neuroprostheses we need to be aware of the context. Context awareness is a major challenge for neuroprostheses and would allow these devices to react more quickly and appropriately to the changing demands of the user and/or task. Traditionally kinematic features are used to extract context information, with most recently the use of joint angles as highly potential features. In this paper we present two algorithms that enable the robust extraction of joint angle and related features to enable long-term continuous monitoring of tremor with context awareness. First, we describe a novel relative sensor placement identification technique based on orientation data. We focus on relative rather than absolute sensor location, because in many medical applications magnetic and inertial measurement units (MIMU) are used in a chain stretching over adjacent segments, or are always placed on a fixed set of locations. Subsequently we demonstrate how tremor parameters can be extracted from orientation data using an adaptive estimation algorithm. Relative sensor location was detected with an accuracy of 94.12% for the 4 MIMU configuration, and 100% for the 3 MIMU configurations. Kinematic tracking error values with an average deviation of 8% demonstrate our ability to estimate tremor from orientation data. The methods presented in this study constitute an important step toward more user-friendly and context-aware neuroprostheses for tremor suppression and monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Consensus Statement of the Movement Disorder Society on Tremor
Deuschl, G., Bain, P., & Brin, M. (2008) · Movement Disorders · doi:10.1002/mds.870131303 · Cited by 1,981 · cited 3×
“The patients were diagnosed by the neurological personnel of the Hospital Frontiers in Neuroscience | Neuroprosthetics July 2014 | Volume 8 | Article 221 | 2 12 de Octubre as definite essential tremor, according to the criteria described in Deuschl et al. (1998).”
MethodA practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Tracking and Kalman Filtering Made Easy
Brookner, E. (1998) · doi:10.1002/0471224197 · Cited by 435 · cited 2×
“, 1998) By estimating the voluntary movement with a g-h filter (Brookner, 1998), and subtracting it from the raw movement data we obtained an estimate of the tremulous movement.”
MethodEstimating Three-Dimensional Orientation of Human Body Parts by Inertial/Magnetic Sensing
Sabatini, A. M. (2011) · Sensors · doi:10.3390/s110201489 · Cited by 349
Wenning, G. K., Kiechl, S., Seppi, K., Müller, J., Högl, B., Saletu, M., Rungger, G., Gasperi, A., Willeit, J., & Poewe, W. (2005) · The Lancet Neurology · doi:10.1016/s1474-4422(05)70226-x · Cited by 302 · cited 3×
“Pathological tremor encompasses all types of tremors that impair motor performance (e.g., essential tremor and parkinsonian tremor; McAuley and Marsden, 2000), and is the most common movement disorder (Wenning et al., 2005).”
BackgroundMethodInfluentialAttenuation of pathological tremors by functional electrical stimulation I: Method
Prochazka, A., Elek, J., & Javidan, M. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368521 · Cited by 150
Electrical stimulation for the suppression of pathological tremor
Popović Maneski, L., Jorgovanović, N., Ilić, V., Došen, S., Keller, T., Popović, M. B., & Popović, D. B. (2011) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-011-0803-6 · Cited by 129
Real-Time Estimation of Pathological Tremor Parameters from Gyroscope Data
Gallego, J., Rocon, E., Roa, J. O., Moreno, J., & Pons, J. L. (2010) · Sensors · doi:10.3390/s100302129 · Cited by 107
Self-citationTremor: Clinical Features, Pathophysiology, and Treatment
Elble, R. J. (2009) · Neurologic Clinics · doi:10.1016/j.ncl.2009.04.003 · Cited by 102 · cited 1×
“Both MEMS accelerometers and gyroscopes are used to monitor tremor (Grimaldi et al., 2008; Elble, 2009).”
MethodEmpirical Mode Decomposition: a novel technique for the study of tremor time series
de Lima, E. R., Andrade, A. O., Pons, J. L., Kyberd, P., & Nasuto, S. J. (2006) · Medical and Biological Engineering and Computing · doi:10.1007/s11517-006-0065-x · Cited by 93
Self-citation
Cited by
Using Portable Transducers to Measure Tremor Severity
Elble, R. J., & McNames, J. (2016) · Tremor and Other Hyperkinetic Movements · doi:10.5334/tohm.320 · Cited by 95
Transducer‐based evaluation of tremor
Haubenberger, D., Abbruzzese, G., Bain, P. G., Bajaj, N., Benito‐León, J., Bhatia, K. P., Deuschl, G., Forjaz, M. J., Hallett, M., Louis, E. D., et al. (2016) · Movement Disorders · doi:10.1002/mds.26671 · Cited by 87
Using Portable Transducers to Measure Tremor Severity
Elble, R., & McNames, J. (2016) · Tremor and Other Hyperkinetic Movements · doi:10.7916/d8dr2vcc · Cited by 43
Characterization of Parkinsonian Hand Tremor and Validation of a High-Order Tremor Estimator
Zhou, Y., Jenkins, M. E., Naish, M. D., & Trejos, A. L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2018.2859793 · Cited by 42
López-Blanco, R., Velasco, M. A., Méndez-Guerrero, A., Romero, J. P., del Castillo, M. D., Serrano, J. I., Benito-León, J., Bermejo-Pareja, F., & Rocon, E. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.02.015 · Cited by 40
Metadata
- Authors
- Lambrecht, S., Gallego, J. A., Rocon, E., & Pons, J. L.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2014-07-24
- Volume
- 8
- Pages
- 221-221
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W1998521469
- Cited by
- 16
- References
- 15
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic real-time monitoring and assessment of tremor parameters in the upper limb from orientation data. https://app.cochat.ai/papers/10.3389/fnins.2014.00221
- The paper
- Lambrecht, S., Gallego, J. A., Rocon, E., & Pons, J. L. (2014). Automatic real-time monitoring and assessment of tremor parameters in the upper limb from orientation data. Frontiers in Neuroscience. https://doi.org/10.3389/fnins.2014.00221
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.