A Sub-millimeter, Inductively Powered Neural Stimulator
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Wireless neural stimulators are being developed to address problems associated with traditional lead-based implants. However, designing wireless stimulators on the sub-millimeter scale (<1mm3) is challenging. As device size shrinks, it becomes difficult to deliver sufficient wireless power to operate the device. Here, we present a sub-millimeter, inductively powered neural stimulator consisting only of a coil to receive power, a capacitor to tune the resonant frequency of the receiver, and a diode to rectify the radio-frequency signal to produce neural excitation. By replacing any complex receiver circuitry with a simple rectifier, we have reduced the required voltage levels that are needed to operate the device from – 0.5 - 1V (e.g. for CMOS) to approximately 0.25 – 0.5V. This reduced voltage allows the use of smaller receive antennas for power, resulting in a device volume of 0.3 – 0.5mm3. The device was encapsulated in epoxy, and successfully passed accelerated lifetime tests in 80°C saline for two weeks. We demonstrate a basic proof-of-concept using stimulation with tens of microamps of current delivered to the sciatic nerve in rat to produce a motor response. The device is designed to operate in tissue up to approximately 5cm depth.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Self-citationNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845 · cited 1×
“We do not have control over the precise distance between the electrode and the nerve, but given that the thickness of the epineurium in rat sciatic nerve, we estimate this distance to be on the order of hundreds of microns (Navarro et al., 2005).”
BackgroundA jump-start for electroceuticals
Famm, K., Litt, B., Tracey, K. J., Boyden, E. S., & Slaoui, M. (2013) · Nature · doi:10.1038/496159a · Cited by 554
Wireless power transfer to deep-tissue microimplants
Ho, J. S., Yeh, A. J., Neofytou, E., Kim, S., Tanabe, Y., Patlolla, B., Beygui, R. E., & Poon, A. S. Y. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1403002111 · Cited by 541 · cited 4×
“Another recent design uses so-called mid-field coupling at Frontiers in Neuroscience | www.frontiersin.org 10 November 2017 | Volume 11 | Article 659 1.6 GHz, resulting in a device that is about 5mm in the longest dimension (Ho et al., 2014).”
BackgroundMethodInfluentialBION ™ system for distributed neural prosthetic interfaces
Loeb, G. E., Peck, R. A., Moore, W. H., & Hood, K. (2001) · Medical Engineering & Physics · doi:10.1016/s1350-4533(01)00011-x · Cited by 243 · cited 3×
“The well-known RF BION uses inductive coupling at 2 MHz with a multi-turn coil with ferrite, but is ∼10 times larger than our device, measuring 16mm in length and 2mm in diameter (Loeb et al., 2001).”
BackgroundMethodMagneto-electric nano-particles for non-invasive brain stimulation.
Yue, K., Guduru, R., Hong, J., Liang, P., Nair, M., & Khizroev, S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0044040 · Cited by 161
Zargham, M., & Gulak, P. G. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2328318 · Cited by 115 · cited 1×
“Zargham and Gulak, 2015; Larson and Nurmikko, 2016).”
Background
Cited by
Piech, D. K., Johnson, B. C., Shen, K., Ghanbari, M. M., Li, K. Y., Neely, R. M., Kay, J. E., Carmena, J. M., Maharbiz, M. M., & Muller, R. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0518-9 · Cited by 442
Recent Advances in Materials, Devices, and Systems for Neural Interfaces
Won, S. M., Song, E., Zhao, J., Li, J., Rivnay, J., & Rogers, J. A. (2018) · Advanced Materials · doi:10.1002/adma.201800534 · Cited by 206
Magnetoelectric materials for miniature, wireless neural stimulation at therapeutic frequencies
Singer, A., Dutta, S., Lewis, E., Chen, Z., Chen, J. C., Verma, N., Avants, B., Feldman, A. K., O’Malley, J., Beierlein, M., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.05.019 · Cited by 202
Wireless power delivery techniques for miniature implantable bioelectronics
Singer, A., & Robinson, J. T. (2021) · Advanced Healthcare Materials · doi:10.1002/adhm.202100664 · Cited by 159
Luan, L., Robinson, J. T., Aazhang, B., Chi, T., Yang, K., Li, X., Rathore, H., Singer, A., Yellapantula, S., Fan, Y., et al. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.011 · Cited by 150
Metadata
- Authors
- Freeman, D. K., O'Brien, J. M., Kumar, P., Daniels, B., Irion, R. A., Shraytah, L., Ingersoll, B. K., Magyar, A. P., Czarnecki, A., Wheeler, J., Coppeta, J. R., Abban, M. P., Gatzke, R., Fried, S. I., Lee, S. W., Duwel, A. E., Bernstein, J. J., Widge, A. S., Hernandez-Reynoso, A., Kanneganti, A., Romero-Ortega, M. I., & Cogan, S. F.
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2017-11-27
- Volume
- 11
- Pages
- 659-659
- ISSN
- 1662-453X (ISSN-L)
- OpenAlex
- W2769624357
- Cited by
- 72
- References
- 7
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Sub-millimeter, Inductively Powered Neural Stimulator. https://app.cochat.ai/papers/10.3389/fnins.2017.00659
- The paper
- Freeman, D. K., O'Brien, J. M., Kumar, P., Daniels, B., Irion, R. A., Shraytah, L., Ingersoll, B. K., Magyar, A. P., Czarnecki, A., Wheeler, J., Coppeta, J. R., Abban, M. P., Gatzke, R., Fried, S. I., Lee, S. W., Duwel, A. E., Bernstein, J. J., Widge, A. S., Hernandez-Reynoso, A., . . . Cogan, S. F. (2017). A Sub-millimeter, Inductively Powered Neural Stimulator. Frontiers in Neuroscience. https://doi.org/10.3389/fnins.2017.00659
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.