Optimizing NV magnetometry for Magnetoneurography and Magnetomyography applications
Open accessThe DOI matches its Crossref record; 66 of the 66 references it cites were found in a registry or an index.
Abstract
Magnetometers based on color centers in diamond are setting new frontiers for sensing capabilities due to their combined extraordinary performances in sensitivity, bandwidth, dynamic range, and spatial resolution, with stable operability in a wide range of conditions ranging from room to low temperatures. This has allowed for its wide range of applications, from biology and chemical studies to industrial applications. Among the many, sensing of bio-magnetic fields from muscular and neurophysiology has been one of the most attractive applications for NV magnetometry due to its compact and proximal sensing capability. Although SQUID magnetometers and optically pumped magnetometers (OPM) have made huge progress in Magnetomyography (MMG) and Magnetoneurography (MNG), exploring the same with NV magnetometry is scant at best. Given the room temperature operability and gradiometric applications of the NV magnetometer, it could be highly sensitive in the pT/Hz-range even without magnetic shielding, bringing it close to industrial applications. The presented work here elaborates on the performance metrics of these magnetometers to the state-of-the-art techniques by analyzing the sensitivity, dynamic range, and bandwidth, and discusses the potential benefits of using NV magnetometers for MMG and MNG applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures







Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Use of Surface Electromyography in Biomechanics
De Luca, C. J. (1997) · Journal of Applied Biomechanics · doi:10.1123/jab.13.2.135 · Cited by 3,268 · cited 1×
“Thereby, one distinguishes electromyography (EMG) (cf. e.g., De Luca, 1997; Merletti and Farina, 2016), which measures muscleinduced electrical potential, and MMG, i.e., recording the muscle-induced magnetic field.”
BackgroundHigh-sensitivity diamond magnetometer with nanoscale resolution
Taylor, J. M., Cappellaro, P., Childress, L., Jiang, L., Budker, D., Hemmer, P. R., Yacoby, A., Walsworth, R., & Lukin, M. D. (2008) · Nature Physics · doi:10.1038/nphys1075 · Cited by 1,959 · cited 2×
“One of the most attractive advantages of the NV magnetometers is the high sensitivity per volume at room temperature, which indicates that the sensors can achieve high sensitivity with a very small sensing volume (Taylor et al., 2008).”
BackgroundBioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Sensitivity optimization for NV-diamond magnetometry
Barry, J. F., Schloss, J. M., Bauch, E., Turner, M. J., Hart, C. A., Pham, L. M., & Walsworth, R. L. (2020) · Reviews of Modern Physics · doi:10.1103/revmodphys.92.015004 · Cited by 1,247 · cited 2×
“accumulated from the interaction between the spins and the external fields is measured to interpret the magnetic fields (Taylor et al., 2008; Barry et al., 2020).”
BackgroundMethodNuclear Magnetic Resonance Spectroscopy on a (5-Nanometer) 3 Sample Volume
Staudacher, T., Shi, F., Pezzagna, S., Meijer, J., Du, J., Meriles, C. A., Reinhard, F., & Wrachtrup, J. (2013) · Science · doi:10.1126/science.1231675 · Cited by 754 · cited 1×
“For most sequences, switching functions can be applied to describe the effects in which a π pulse switches the constant value between +1 and −1 (Staudacher et al., 2013).”
BackgroundSelf-citationMultichannel Blind Source Separation Using Convolution Kernel Compensation
Holobar, A., & Zazula, D. (2007) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2007.896108 · Cited by 648
Multi-channel intramuscular and surface EMG decomposition by convolutive blind source separation
Negro, F., Muceli, S., Castronovo, A. M., Holobar, A., & Farina, D. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/2/026027 · Cited by 647 · cited 1×
“Accordingly, non-invasive MMG is superior to EMG for distinguishing spatially shifted muscle fiber sources; something highly desirable, for example, for decomposing an interference signal into the spike trains of individual motor units (e.g., Holobar and Zazula, 2007; De Luca et al., 2015; Negro et al., 2016) and for…”
BackgroundOptical magnetic detection of single-neuron action potentials using quantum defects in diamond
Barry, J. F., Turner, M. J., Schloss, J. M., Glenn, D. R., Song, Y., Lukin, M. D., Park, H., & Walsworth, R. L. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1601513113 · Cited by 637
The extraction of neural strategies from the surface EMG: an update
Farina, D., Merletti, R., & Enoka, R. M. (2014) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00162.2014 · Cited by 589 · cited 1×
“Considering well-established EMG measurements, signals can be measured invasively via needle or fine-wire electrodes (Merletti and Farina, 2009) or by means of noninvasive surface electrodes (Farina et al., 2014).”
BackgroundAdvances in Magnetic Field Sensors
Ripka, P., & Janosek, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2043429 · Cited by 546 · cited 1×
“However, these sensors have a trade-off between the sensitivity and the sensor volume, and the miniaturized sensors usually have a sensitivity in the range of a few nT—50 pT (Chaves et al., 2007; Ripka and Janosek, 2010; Liou et al., 2011; Cubells-Beltrán et al., 2016; Zuo et al., 2020).”
BackgroundDréau, A., Lesik, M., Rondin, L., Spinicelli, P., Arcizet, O., Roch, J.-F., & Jacques, V. (2011) · Physical Review B · doi:10.1103/physrevb.84.195204 · Cited by 523 · cited 1×
“In the CW-ODMR scheme, high laser power broadens the linewidth (linewidth narrowing barely happens when the T∗ 2 is a few μs long) and reduces the signal contrast, and high MW power also broadens the linewidth and deteriorates the sensitivity of CWODMR measurements (Dréau et al., 2011; Jensen et al., 2013).”
BackgroundSurface Electromyography : Physiology, Engineering, and Applications
(2016) · doi:10.1002/9781119082934 · Cited by 462 · cited 10×
“However, whether MMG provides any advantage over EMG for obtaining novel insights into the neuromuscular system has yet to be explored experimentally.”
BackgroundInfluential(1989) · Springer eBooks · doi:10.1007/978-1-4613-0581-1 · Cited by 452 · cited 1×
“The decrease of the magnetic fields with increasing distance from single nerves has been investigated theoretically and experimentally and is dependent on the length of the fiber and the distance itself (Williamson and Hoke, 2012).”
BackgroundSkeletal Muscle Form and Function
MacIntosh, B. R., Gardiner, P. F., & McComas, A. J. (2006) · Human Kinetics eBooks · doi:10.5040/9781492596912 · Cited by 451
Heckman, C. J., & Enoka, R. M. (2012) · Comprehensive Physiology · doi:10.1002/cphy.c100087 · Cited by 414 · cited 1×
“Skeletal muscle contraction is controlled by the nervous system (Kandel et al., 2000; Heckman and Enoka, 2012) through electric signals (MacIntosh et al.”
BackgroundSubpicotesla Diamond Magnetometry
Wolf, T., Neumann, P., Nakamura, K., Sumiya, H., Ohshima, T., Isoya, J., & Wrachtrup, J. (2015) · Physical Review X · doi:10.1103/physrevx.5.041001 · Cited by 378
Self-citationNanoscale nuclear magnetic resonance with chemical resolution
Aslam, N., Pfender, M., Neumann, P., Reuter, R., Zappe, A., Fávaro de Oliveira, F., Denisenko, A., Sumiya, H., Onoda, S., Isoya, J., et al. (2017) · Science · doi:10.1126/science.aam8697 · Cited by 332 · cited 1×
“This property is used for nuclear magnetic resonance applications to achieve a high-frequency resolution (Aslam et al., 2017).”
MethodSelf-citationUltrasensitive Magnetic Field Sensors for Biomedical Applications
Murzin, D., Mapps, D. J., Levada, K., Belyaev, V., Omelyanchik, A., Panina, L., & Rodionova, V. (2020) · Sensors · doi:10.3390/s20061569 · Cited by 277
Ultralong Dephasing Times in Solid-State Spin Ensembles via Quantum Control
Bauch, E., Hart, C. A., Schloss, J. M., Turner, M. J., Barry, J. F., Kehayias, P., Singh, S., & Walsworth, R. L. (2018) · Physical Review X · doi:10.1103/physrevx.8.031025 · Cited by 231 · cited 2×
“However, these errors are shown to be suppressed by methods such as the double quantummagnetometry (Mamin et al., 2014; Bauch et al., 2018; Barry et al., 2020).”
BackgroundMethodQuantum enhanced optomechanical magnetometry
Li, B.-B., Bílek, J., Hoff, U. B., Madsen, L. S., Forstner, S., Prakash, V., Schäfermeier, C., Gehring, T., Bowen, W. P., & Andersen, U. L. (2018) · Optica · doi:10.1364/optica.5.000850 · Cited by 203
Clinical application of magnetocardiography
Fenici, R., Brisinda, D., & Meloni, A. M. (2005) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.5.3.291 · Cited by 174 · cited 1×
“One specific bio-magnetic field sensing modality is magnetocardiography (MCG), measuring the magnetic field stemming from the electric excitation of the heart (Fenici et al., 2005).”
BackgroundLight narrowing of magnetic resonances in ensembles of nitrogen-vacancy centers in diamond
Jensen, K., Acosta, V. M., Jarmola, A., & Budker, D. (2013) · Physical Review B · doi:10.1103/physrevb.87.014115 · Cited by 159 · cited 1×
“In the CW-ODMR scheme, high laser power broadens the linewidth (linewidth narrowing barely happens when the T∗ 2 is a few μs long) and reduces the signal contrast, and high MW power also broadens the linewidth and deteriorates the sensitivity of CWODMR measurements (Dréau et al., 2011; Jensen et al., 2013).”
BackgroundDiamond magnetometer enhanced by ferrite flux concentrators
Fescenko, I., Jarmola, A., Savukov, I., Kehayias, P., Smits, J., Damron, J., Ristoff, N., Mosavian, N., & Acosta, V. M. (2020) · Physical Review Research · doi:10.1103/physrevresearch.2.023394 · Cited by 158 · cited 2×
“Hyperfine driving and double resonance driving are used to enhance the sensitivity (Fescenko et al., 2020; Zhang et al., 2021).”
BackgroundAnalysis of intramuscular electromyogram signals
Merletti, R., & Farina, D. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2008.0235 · Cited by 153 · cited 1×
“Considering well-established EMG measurements, signals can be measured invasively via needle or fine-wire electrodes (Merletti and Farina, 2009) or by means of noninvasive surface electrodes (Farina et al.”
BackgroundDecomposition of surface EMG signals from cyclic dynamic contractions
Luca, C. J. D., Chang, S.-S., Roy, S. H., Kline, J. C., & Nawab, S. H. (2014) · Journal of Neurophysiology · doi:10.1152/jn.00555.2014 · Cited by 153
A multiple-layer finite-element model of the surface EMG signal
Lowery, M. M., Stoykov, N. S., Taflove, A., & Kuiken, T. A. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.995683 · Cited by 152
High Bandwidth Atomic Magnetometery with Continuous Quantum Nondemolition Measurements
Shah, V., Vasilakis, G., & Romalis, M. V. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.013601 · Cited by 150 · cited 1×
“However, there is usually a trade-off between the dynamic range and sensitivity of a sensor (Shah et al., 2010).”
BackgroundVolume conduction models for surface EMG; confrontation with measurements
Roeleveld, K., Blok, J. H., Stegeman, D. F., & van Oosterom, A. (1997) · Journal of Electromyography and Kinesiology · doi:10.1016/s1050-6411(97)00009-6 · Cited by 141 · cited 1×
“, acting as a low-pass filter (Roeleveld et al., 1997; Lowery et al., 2002; Klotz et al., 2020), and hence, the signal provides a more global view of the muscle.”
BackgroundDiamond Magnetometry and Gradiometry Towards Subpicotesla dc Field Measurement
Zhang, C., Shagieva, F., Widmann, M., Kübler, M., Vorobyov, V., Kapitanova, P., Nenasheva, E., Corkill, R., Rhrle, O., Nakamura, K., et al. (2021) · Physical Review Applied · doi:10.1103/physrevapplied.15.064075 · Cited by 138 · cited 5×
“5μs was reported and found as one of the longest T∗ 2 in experiments (Zhang et al., 2021), and the calculated sensitivity that can be achieved is about 2.”
BackgroundMethodSelf-citationSQUID sensor array configurations for magnetoencephalography applications
Vrba, J., & Robinson, S. E. (2002) · Superconductor Science and Technology · doi:10.1088/0953-2048/15/9/201 · Cited by 126 · cited 1×
“Otherwise, array configurations are required for improving the signal noise ratio (Vrba and Robinson, 2002; Clancy et al., 2021).”
BackgroundRobust high-dynamic-range vector magnetometry with nitrogen-vacancy centers in diamond
Clevenson, H., Pham, L., Teale, C., Johnson, K., Englund, D. R., & Braje, D. (2018) · Applied Physics Letters · doi:10.1063/1.5034216 · Cited by 123
Miniaturized Magnetic Sensors for Implantable Magnetomyography
Zuo, S., Heidari, H., Farina, D., & Nazarpour, K. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000185 · Cited by 122 · cited 1×
“However, these sensors have a trade-off between the sensitivity and the sensor volume, and the miniaturized sensors usually have a sensitivity in the range of a few nT—50 pT (Chaves et al., 2007; Ripka and Janosek, 2010; Liou et al., 2011; Cubells-Beltrán et al., 2016; Zuo et al., 2020).”
BackgroundMagnetomyography: magnetic fields around the human body produced by skeletal muscles
Cohen, D., & Givler, E. (1972) · Applied Physics Letters · doi:10.1063/1.1654294 · Cited by 109
Low frequency picotesla field detection using hybrid MgO based tunnel sensors
Chaves, R. C., Freitas, P. P., Ocker, B., & Maaß, W. (2007) · Applied Physics Letters · doi:10.1063/1.2775802 · Cited by 108
Optimizing a dynamical decoupling protocol for solid-state electronic spin ensembles in diamond
Farfurnik, D., Jarmola, A., Pham, L., Wang, Z. H., Dobrovitski, V. V., Walsworth, R. L., Budker, D., & Bar‐Gill, N. (2015) · Physical Review B · doi:10.1103/physrevb.92.060301 · Cited by 107 · cited 1×
“The XY8 sequence is an alternate dynamical decoupling sequence that can reduce the influence of the pulse errors (Farfurnik et al., 2015).”
BackgroundHeterodyne sensing of microwaves with a quantum sensor
Meinel, J., Vorobyov, V., Yavkin, B. V., Dasari, D., Sumiya, H., Onoda, S., Isoya, J., & Wrachtrup, J. (2021) · Nature Communications · doi:10.1038/s41467-021-22714-y · Cited by 104
Self-citationMultipulse Double-Quantum Magnetometry with Near-Surface Nitrogen-Vacancy Centers
Mamin, H. J., Sherwood, M. H., Kim, M., Rettner, C. T., Ohno, K., Awschalom, D. D., & Rugar, D. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.030803 · Cited by 101
High-dynamic-range magnetometry with a single electronic spin in diamond
Nusran, N., Momeen, M. U., & Dutt, M. V. G. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.225 · Cited by 94 · cited 1×
“Phase-estimation-algorithm (PEA) and QPSD technique can be used to extend the dynamic range of NV sensors based on interferometry schemes (Nusran et al., 2012; Zhang et al., 2022).”
MethodIntegration of GMR Sensors with Different Technologies
Cubells‐Beltrán, M., Reig, C., Madrenas, J., Marcellis, A. D., Santos, J. D., Cardoso, S., & Freitas, P. P. (2016) · Sensors · doi:10.3390/s16060939 · Cited by 93
Röhrle, O., Yavuz, U. Ş., Klotz, T., Negro, F., & Heidlauf, T. (2019) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1457 · Cited by 93
Self-citationSensing of Arbitrary-Frequency Fields Using a Quantum Mixer
Wang, G., Liu, Y.-X., Schloss, J. M., Alsid, S. T., Braje, D., & Cappellaro, P. (2022) · Physical Review X · doi:10.1103/physrevx.12.021061 · Cited by 85
Stepanov, V., Cho, F. H., Abeywardana, C., & Takahashi, S. (2015) · Applied Physics Letters · doi:10.1063/1.4908528 · Cited by 70
Biomagnetic functional localization of a peripheral nerve in man
Trahms, L., Erne, S. N., Trontelj, Z., Curio, G., & Aust, P. (1989) · Biophysical Journal · doi:10.1016/s0006-3495(89)82911-x · Cited by 68 · cited 1×
“The dispersion effect of the nerve conduction velocity leads to a quadratic distance dependence of the magnetic fields (Trahms et al., 1989).”
BackgroundHeterodyne sensing of microwaves with a quantum sensor
Meinel, J., Vorobyov, V., Yavkin, B. V., et al. (2021) · RePEc: Research Papers in Economics · Cited by 68
Picotesla Magnetic Sensors for Low-Frequency Applications
Liou, S. H., Yin, X., Russek, S. E., Heindl, R., Silva, F. C. S. D., Moreland, J., Pappas, D. P., Yuan, L., & Shen, J. (2011) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2011.2157997 · Cited by 64 · cited 1×
“However, these sensors have a trade-off between the sensitivity and the sensor volume, and the miniaturized sensors usually have a sensitivity in the range of a few nT—50 pT (Chaves et al., 2007; Ripka and Janosek, 2010; Liou et al., 2011; Cubells-Beltrán et al., 2016; Zuo et al., 2020).”
Backgrounddc Magnetometry with Engineered Nitrogen-Vacancy Spin Ensembles in Diamond
Balasubramanian, P., Osterkamp, C., Chen, Y., Chen, X., Teraji, T., Wu, E., Naydenov, B., & Jelezko, F. (2019) · Nano Letters · doi:10.1021/acs.nanolett.9b02993 · Cited by 63 · cited 1×
“There are also cases that dynamical decoupling techniques, such as the WAHUHA sequence, are used to address the dipole-dipole interactions to extend T∗ 2 and to improve the dc sensitivity (Balasubramanian et al., 2019).”
MethodRoom-temperature operation of a radiofrequency diamond magnetometer near the shot-noise limit
Shin, C. S., Avalos, C. E., Butler, M. C., Trease, D. R., Seltzer, S. J., Peter Mustonen, J., Kennedy, D. J., Acosta, V. M., Budker, D., Pines, A., et al. (2012) · Journal of Applied Physics · doi:10.1063/1.4771924 · Cited by 59 · cited 1×
“One is based on the ODMR spectrum, in which the shifts of the resonant lines detect external magnetic fields (Shin et al., 2012).”
BackgroundUltrabroadband and sensitive cavity optomechanical magnetometry
Li, B., Brawley, G. A., Greenall, H., Forstner, S., Sheridan, E., Rubinsztein-Dunlop, H. H., & Bowen, W. P. (2020) · Photonics Research · doi:10.1364/prj.390261 · Cited by 58
Cross-Axis Dynamic Field Compensation of Optically Pumped Magnetometer Arrays for MEG
Robinson, S. E., Benitez-Andonegui, A., Holroyd, T., Hughes, K. J., Alem, O., Knappe, S. A., Maydew, T., Griesshammer, A., & Nugent, A. C. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119559 · Cited by 55 · cited 7×
“For example, OPMs with fT sensitivity mostly require magnetic shielding to maintain the near-zero operation field range.”
BackgroundInfluentialInvited Article: Scalable high-sensitivity optomechanical magnetometers on a chip
Li, B., Bulla, D. A. P., Prakash, V., Forstner, S., Dehghan‐Manshadi, A., Rubinsztein-Dunlop, H. H., Foster, S. B., & Bowen, W. P. (2018) · APL Photonics · doi:10.1063/1.5055029 · Cited by 48
Craik, D. P. L. A., Kehayias, P., Greenspon, A. S., Zhang, X., Turner, M. J., Schloss, J. M., Bauch, E., Hart, C. A., Hu, E. L., & Walsworth, R. L. (2020) · Physical Review Applied · doi:10.1103/physrevapplied.14.014009 · Cited by 41 · cited 2×
“To optimize the LPF, we estimate the charge state ratio based on the microwaveassisted spectroscopy method (Craik et al., 2020).”
MethodOptically pumped magnetometers reveal fasciculations non-invasively
Marquetand, J. C., Middelmann, T., Dax, J., Baek, S., Sometti, D., Grimm, A. M., Lerche, H., Martin, P., Kronlage, C., Siegel, M., et al. (2021) · Clinical Neurophysiology · doi:10.1016/j.clinph.2021.06.009 · Cited by 38 · cited 1×
“, 2016) and for detecting hallmarks of neuromuscular disorders (e.g., Rubin, 2019; Marquetand et al., 2021).”
BackgroundInvestigating the spatial resolution of EMG and MMG based on a systemic multi-scale model
Klotz, T., Gizzi, L., & Röhrle, O. (2022) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-022-01572-7 · Cited by 38 · cited 2×
“A recent simulation study (Klotz et al., 2022) shows that MMG signals are less affected by subcutaneous fat than a corresponding EMG signal.”
BackgroundMethodSelf-citationA study of scalar optically-pumped magnetometers for use in magnetoencephalography without shielding
Clancy, R. J., Gerginov, V., Alem, O., Becker, S., & Knappe, S. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ac18fb · Cited by 37 · cited 3×
“Besides, efforts have been made to enhance the dynamic range of NVmagnetometers (Clancy et al., 2021; Zhang et al., 2022), and the dynamic range of NV magnetometers is much larger than the OPMs.”
BackgroundExtending resection and preserving function: modern concepts of glioma surgery
Schucht, P., Beck, J., Seidel, K., & Raabe, A. (2015) · Swiss Medical Weekly · doi:10.4414/smw.2015.14082 · Cited by 35 · cited 1×
“, the localization of critical nerve bundles such as the facial nerve in cochlea implant surgery or during brain tumor resection (Heman-Ackah et al., 2013; Schucht et al., 2015).”
BackgroundIs facial nerve integrity monitoring of value in chronic ear surgery?
Heman‐Ackah, S. E., Gupta, S., & Lalwani, A. K. (2012) · The Laryngoscope · doi:10.1002/lary.23363 · Cited by 29
Normal and abnormal spontaneous activity
Rubin, D. I. (2019) · Handbook of clinical neurology · doi:10.1016/b978-0-444-64032-1.00017-5 · Cited by 29 · cited 1×
“…highly desirable, for example, for decomposing an interference signal into the spike trains of individual motor units (e.g., Holobar and Zazula, 2007; De Luca et al., 2015; Negro et al., 2016) and for detecting hallmarks of neuromuscular disorders (e.g., Rubin, 2019; Marquetand et al., 2021).”
BackgroundModelling the electrical activity of skeletal muscle tissue using a multi-domain approach
Klotz, T., Gizzi, L., Yavuz, U. Ş., & Röhrle, O. (2019) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-019-01214-5 · Cited by 28 · cited 1×
“, acting as a low-pass filter (Roeleveld et al., 1997; Lowery et al., 2002; Klotz et al., 2020), and hence, the signal provides a more global view of the muscle.”
BackgroundSelf-citationT2 -limited sensing of static magnetic fields via fast rotation of quantum spins
Wood, A. A., Aeppli, A. G., Lilette, E., Fein, Y. Y., Stacey, A. D., Hollenberg, L. C. L., Scholten, R. E., & Martin, A. (2018) · Physical review. B./Physical review. B · doi:10.1103/physrevb.98.174114 · Cited by 27 · cited 1×
“Modulation techniques can be a solution to up-covert the dc field to a high-frequency ac field, and the ac magnetometry sequences can be applied to achieve T2 limited sensitivity (Wood et al., 2018; Xie et al., 2022).”
Gradiometer Using Separated Diamond Quantum Magnetometers
MASUYAMA, Y., Suzuki, K., Hekizono, A., Iwanami, M., Hatano, M., Iwasaki, T., & Ohshima, T. (2021) · Sensors · doi:10.3390/s21030977 · Cited by 23
Clinical aspects of biological fields: an introduction for health care professionals
Oschman, J. L. (2002) · Journal of Bodywork and Movement Therapies · doi:10.1054/jbmt.2001.0259 · Cited by 21 · cited 1×
“Unlike electrical potentials, magnetic fields can be propagated through the body without distortion (Malmivuo et al., 1995; Oschman, 2002).”
BackgroundQuantum-assisted distortion-free audio signal sensing
Zhang, C., Dasari, D. B. R., Widmann, M., Meinel, J., Vorobyov, V., Kapitanova, P. V., Nenasheva, E. A., Nakamura, K. T., Sumiya, H., Onoda, S., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-32150-1 · Cited by 20
Self-citationProspective Validation of Facial Nerve Monitoring to Prevent Nerve Damage During Robotic Drilling
Ansó, J., Dür, C., Apelt, M., Venail, F., Scheidegger, O., Seidel, K., Rohrbach, H., Forterre, F., Dettmer, M. S., Zlobec, I., et al. (2019) · Frontiers in Surgery · doi:10.3389/fsurg.2019.00058 · Cited by 14 · cited 1×
“Currently, intraoperative monitoring of these structures is usually done by electrical stimulation techniques that suffer from patient-specific differences in tissue morphology and tissue impedance (Ansó et al., 2019).”
BackgroundToward T2-Limited DC Diamond Quantum Magnetometry via Flux Concentration and Modulation
Xie, Y., Xie, C., Zhu, Y., Jing, K., Tong, Y., Qin, X., Guan, H., Duan, C., Wang, Y., & Rong, X. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3299596 · Cited by 14
Furlong, P. L., Foley, E., Witton, C., & Seri, S. (2016) · Oxford University Press eBooks · doi:10.1093/med/9780199688395.003.0013 · Cited by 8
$T_2$-limited dc Quantum Magnetometry via Flux ModulationPreprint
Xie, Y., Xie, C., Zhu, Y., et al. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2204.07343 · Cited by 1 · cited 1×
“Modulation techniques can be a solution to up-covert the dc field to a high-frequency ac field, and the ac magnetometry sequences can be applied to achieve T2 limited sensitivity (Wood et al., 2018; Xie et al., 2022).”
Research works printed but not linked: 2
- Kandel E. R. Schwartz J. H. Jessell T. M. Siegelbaum S. Hudspeth A. J. Mack S.. (2000). Principles of Neural Science, Vol. 4. New York, NY: McGraw-Hill.
- Wolf T. (2018). On magnetometry using ensembles of NV defect centers in diamond [Dissertation]. Universität Stuttgart, Stuttgart, Germany.
Cited by
Clinical magnetocardiography: the unshielded bet—past, present, and future
Brisinda, D., Fenici, P., & Fenici, R. (2023) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2023.1232882 · Cited by 80
Yu, Y.-H., Zhang, R., Xu, Y., Chen, X.-Q., Zheng, H., Li, Q., Liu, R., Pan, X., Budker, D., & Liu, G. (2024) · Physical Review Applied · doi:10.1103/physrevapplied.21.044051 · Cited by 26
Klotz, T., Lehmann, L., Negro, F., & Röhrle, O. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/ace7f7 · Cited by 24
Self-citationRoth, B. J. (2024) · Biophysics Reviews · doi:10.1063/5.0201950 · Cited by 24
Bright Quantum-Grade Fluorescent Nanodiamonds
Oshimi, K., Ishiwata, H., Nakashima, H., Mandić, S., Kobayashi, H., Teramoto, M., Tsuji, H., Nishibayashi, Y., Shikano, Y., An, T., et al. (2024) · ACS Nano · doi:10.1021/acsnano.4c03424 · Cited by 23
“These bulk diamonds exhibited high NV spin qualities and demonstrated fascinating applications, including nanoscale nuclear magnetic resonance [30, 31] and neural monitoring [7, 32].”
Metadata
- Authors
- Zhang, C., Zhang, J., Widmann, M., Benke, M., Kübler, M., Dasari, D., Klotz, T., Gizzi, L., Röhrle, O., Brenner, P., & Wrachtrup, J.
- Affiliations
- University of Stuttgart (DE)
- Corresponding author
- Zhang, Chen
- Wrachtrup, Jörg
- ORCID
- Venue
- Frontiers in Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2023-01-12
- Volume
- 16
- Pages
- 1034391-1034391
- ISSN
- 1662-453X (ISSN-L)
- PMC
- PMC9885266
- OpenAlex
- W4315640927
- Cited by
- 34
- References
- 66
- Citations by year
- 2026: 15 · 2025: 7 · 2024: 9 · 2023: 3
- FWCI
- 2.51
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Frontiers in Neuroscience (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- OPUS Publication Server of the University of Stuttgart (University of Stuttgart) (submittedVersion, cc-by)
- Fraunhofer-Publica (Fraunhofer-Gesellschaft) (submittedVersion)
- Universitätsbibliothek Stuttgart (cc-by)
- Funders
- European Commission (742610, 820394, HORIZON2020)
- Bundesministerium für Bildung und Forschung
- H2020 European Research Council (742610)
- HORIZON EUROPE European Research Council (101055186)
- Topics
- Physical Sciences › Materials Science › Materials Chemistry › Diamond and Carbon-based Materials Research
- Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
- Keywords
- diamond color centers, magnetomyography, magnetometer sensitivity, dynamic range, bandwidth, room-temperature operation
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.