The flexDrive: an ultra-light implant for optical control and highly parallel chronic recording of neuronal ensembles in freely moving mice
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Electrophysiological recordings from ensembles of neurons in behaving mice are a central tool in the study of neural circuits. Despite the widespread use of chronic electrophysiology, the precise positioning of recording electrodes required for high-quality recordings remains a challenge, especially in behaving mice. The complexity of available drive mechanisms, combined with restrictions on implant weight tolerated by mice, limits current methods to recordings from no more than 4-8 electrodes in a single target area. We developed a highly miniaturized yet simple drive design that can be used to independently position 16 electrodes with up to 64 channels in a package that weighs ~2 g. This advance over current designs is achieved by a novel spring-based drive mechanism that reduces implant weight and complexity. The device is easy to build and accommodates arbitrary spatial arrangements of electrodes. Multiple optical fibers can be integrated into the recording array and independently manipulated in depth. Thus, our novel design enables precise optogenetic control and highly parallel chronic recordings of identified single neurons throughout neural circuits in mice.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Driving fast-spiking cells induces gamma rhythm and controls sensory responses
Cardin, J. A., Carlén, M., Meletis, K., Knoblich, U., Zhang, F., Deisseroth, K., Tsai, L.-H., & Moore, C. I. (2009) · Nature · doi:10.1038/nature08002 · Cited by 2,603
Self-citationTop-Down Versus Bottom-Up Control of Attention in the Prefrontal and Posterior Parietal Cortices
Buschman, T. J., & Miller, E. K. (2007) · Science · doi:10.1126/science.1138071 · Cited by 2,380
Dynamics of the Hippocampal Ensemble Code for Space
Wilson, M. A., & McNaughton, B. L. (1993) · Science · doi:10.1126/science.8351520 · Cited by 2,350 · cited 2×
“While the use of tetrodes (Wilson and McNaughton, 1993; Gray et al., 1995; Jog et al., 2002; Nguyen et al., 2009) or stereotrodes (McNaughton et al.”
BackgroundMethodResponse of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896 · cited 1×
“…2013 | Volume 7 | Article 8 | 1 SYSTEMS NEUROSCIENCE that any electrode can yield high quality single-unit data is gliosis, the process of successive encapsulation of foreign materials by glial cells that insulate the electrode from surrounding neurons (Turner et al., 1999; Polikov et al., 2005).”
BackgroundBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875 · cited 3×
“METHODS ARTICLE published: 13 May 2013 doi: 10.3389/fnsys.2013.00008 The flexDrive: an ultra-light implant for optical control and highly parallel chronic recording of neuronal ensembles in freely moving mice Jakob Voigts1,2, Joshua H. Siegle1,2, Dominique L. Pritchett 2,3 and Christopher I. Moore2* 1 Department of Br…”
BackgroundInfluentialImaging large-scale neural activity with cellular resolution in awake, mobile mice
Dombeck, D. A., Khabbaz, A. N., Collman, F., Adelman, T. L., & Tank, D. W. (2007) · Neuron · doi:10.1016/j.neuron.2007.08.003 · Cited by 1,099 · cited 2×
“Despite the widespread use of chronic electrophysiology, the precise positioning of recording electrodes required for high-quality recordings remains a challenge, especially in behaving mice.”
BackgroundOptogenetic investigation of neural circuits underlying brain disease in animal models
Tye, K. M., & Deisseroth, K. (2012) · Nature Reviews Neuroscience · doi:10.1038/nrn3171 · Cited by 745 · cited 1×
“Recently, studies have demonstrated the great utility of simultaneous optogenetic interventions and single- and multi-unit recordings from awake, behaving mice (Halassa et al., 2011; Tye and Deisseroth, 2012).”
BackgroundChronic, multisite, multielectrode recordings in macaque monkeys
Nicolelis, M. A. L., Dimitrov, D., Carmena, J. M., Crist, R., Lehew, G., Kralik, J. D., & Wise, S. P. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1934665100 · Cited by 740
Single-Unit Stability Using Chronically Implanted Multielectrode Arrays
Dickey, A. S., Suminski, A., Amit, Y., & Hatsopoulos, N. G. (2009) · Journal of Neurophysiology · doi:10.1152/jn.90920.2008 · Cited by 234 · cited 1×
“…of glial encapsulation begins as early as one day post-implant (Fujita et al., 1998) and can lead to a progressive deterioration in the experimenter’s ability to identify and discriminate individual neurons (Williams et al., 1999; Vetter et al., 2004; Dickey et al., 2009; Muthuswamy et al., 2011).”
Background
Cited by
Tools for Probing Local Circuits: High-Density Silicon Probes Combined with Optogenetics
Buzsáki, G., Stark, E., Berényi, A., Khodagholy, D., Kipke, D. R., Yoon, E., & Wise, K. D. (2015) · Neuron · doi:10.1016/j.neuron.2015.01.028 · Cited by 334
Challenges and opportunities for large-scale electrophysiology with Neuropixels probes
Steinmetz, N. A., Koch, C., Harris, K. D., & Carandini, M. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.009 · Cited by 333
Stable long-term chronic brain mapping at the single-neuron level
Fu, T.-M., Hong, G., Zhou, T., Schuhmann, T. G., Viveros, R. D., & Lieber, C. M. (2016) · Nature Methods · doi:10.1038/nmeth.3969 · Cited by 330
Slow waves, sharp waves, ripples, and REM in sleeping dragons
Shein-Idelson, M., Ondracek, J. M., Liaw, H.-P., Reiter, S., & Laurent, G. (2016) · Science · doi:10.1126/science.aaf3621 · Cited by 274
Siegle, J. H., & Wilson, M. A. (2014) · eLife · doi:10.7554/elife.03061 · Cited by 271
Self-citationDistinct Roles of Parvalbumin- and Somatostatin-Expressing Interneurons in Working Memory
Kim, D., Jeong, H., Lee, J., Ghim, J.-W., Her, E. S., Lee, S.-H., & Jung, M. W. (2016) · Neuron · doi:10.1016/j.neuron.2016.09.023 · Cited by 201
System for recording from multiple flexible polyimide neural probes in freely behaving animals
van Daal, R. J. J., Sun, J.-J., Ceyssens, F., Michon, F., Kraft, M., Puers, R., & Kloosterman, F. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab5e19 · Cited by 18
Metadata
- Authors
- Voigts, J., Siegle, J. H., Pritchett, D. L., & Moore, C. I.
- Venue
- Frontiers in Systems Neuroscience
- Publisher
- Frontiers Media SA
- Published
- 2013
- Volume
- 7
- Pages
- 8-8
- ISSN
- 1662-5137 (ISSN-L)
- OpenAlex
- W2140011966
- Cited by
- 147
- References
- 9
- FWCI
- 3.35
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.