The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Echocardiographic Evaluation of Hemodynamics in Neonates and Children
Open accessAbstract
Hemodynamic instability and inadequate cardiac performance are common in critically ill children. The clinical assessment of hemodynamic status is reliant upon physical examination supported by the clinical signs such as heart rate, blood pressure, capillary refill time, and measurement of the urine output and serum lactate. Unfortunately, all of these parameters are surrogate markers of cardiovascular well-being and they provide limited direct information regarding the adequacy of blood flow and tissue perfusion. A bedside point-of-care echocardiography can provide real-time hemodynamic information by assessing cardiac function, loading conditions (preload and afterload) and cardiac output. The echocardiography has the ability to provide longitudinal functional assessment in real time, which makes it an ideal tool for monitoring hemodynamic assessment in neonates and children. It is indispensable in the management of patients with shock, pulmonary hypertension, and patent ductus arteriosus. The echocardiography is the gold standard diagnostic tool to assess hemodynamic stability in patients with pericardial effusion, cardiac tamponade, and cardiac abnormalities such as congenital heart defects or valvar disorders. The information from echocardiography can be used to provide targeted treatment in intensive care settings such as need of fluid resuscitation versus inotropic support, choosing appropriate inotrope or vasopressor, and in providing specific interventions such as selective pulmonary vasodilators in pulmonary hypertension. The physiological information gathered from echocardiography may help in making timely, accurate, and appropriate diagnosis and providing specific treatment in sick patients. There is no surprise that use of bedside point-of-care echocardiography is rapidly gaining interest among neonatologists and intensivists, and it is now being used in clinical decision making for patients with hemodynamic instability. Like any other investigation, it has certain limitations and the most important limitation is its intermittent nature. Sometimes acquiring high quality images for precise functional assessment in a ventilated child can be challenging. Therefore, it should be used in conjunction with the existing tools (physical examination and clinical parameters) for hemodynamic assessment while making clinical decisions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Figures












Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“TNE can lead to changes in clinical management in approximately 30–60% of patients with hemodynamic instability [50].”
From Trends and Challenges in Noninvasive Hemodynamic Monitoring of Neonates Following Cardiac Surgery: A Narrative Review (2025) · cites this paper as [50]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lang, R. M., Bierig, M., Devereux, R. B., Flachskampf, F. A., Foster, E., Pellikka, P. A., Picard, M. H., Roman, M. J., Seward, J., Shanewise, J. S., et al. (2005) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2005.10.005 · Cited by 11,318
Rudski, L., Lai, W. W., Afilalo, J., Hua, L., Handschumacher, M. D., Chandrasekaran, K., Solomon, S. D., Louie, E. K., & Schiller, N. B. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.05.010 · Cited by 7,080
Cecconi, M., Backer, D. D., Antonelli, M. M., Beale, R. J., Bakker, J., Hofer, C. K., Jaeschke, R., Mebazaa, A., Pinsky, M. R., Teboul, J., et al. (2014) · Intensive Care Medicine · doi:10.1007/s00134-014-3525-z · Cited by 1,849
Lopez, L., Colan, S. D., Frommelt, P. C., Ensing, G. J., Kendall, K., Younoszai, A. K., Lai, W. W., & Geva, T. (2010) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2010.03.019 · Cited by 1,557
Vincent, J., & Backer, D. D. (2013) · New England Journal of Medicine · doi:10.1056/nejmra1208943 · Cited by 1,532
The respiratory variation in inferior vena cava diameter as a guide to fluid therapy
Feissel, M., Michard, F., Faller, J.-P., & Teboul, J. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2233-5 · Cited by 963
Barbier, C., Loubières, Y., Schmit, C., Hayon, J., Ricôme, J.-L., Jardin, F., & Vieillard‐Baron, A. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2259-8 · Cited by 934
Feissel, M., Michard, F., Mangin, I., Ruyer, O., Faller, J.-P., & Teboul, J. (2001) · CHEST Journal · doi:10.1378/chest.119.3.867 · Cited by 607
Strain and strain rate imaging: a new clinical approach to quantifying regional myocardial function
Sutherland, G. R., Salvo, G. D., Claus, P., D’hooge, J., & Bijnens, B. H. (2004) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2004.03.027 · Cited by 604
Superior vena cava flow in newborn infants: a novel marker of systemic blood flow
Kluckow, M. R., & Evans, N. (2000) · Archives of Disease in Childhood Fetal & Neonatal · doi:10.1136/fn.82.3.f182 · Cited by 404
Cited by
Sorted by citations
Singh, Y., Tissot, C., Fraga, M. V., Yousef, N., Cortes, R. G., Lopez, J., Sanchez-de-Toledo, J., Brierley, J., Colunga, J. M., Raffaj, D., et al. (2020) · Critical Care · doi:10.1186/s13054-020-2787-9 · Cited by 659
Self-citationEchocardiographic Evaluation of Ventricular Function—For the Neonatologist and Pediatric Intensivist
Tissot, C., Singh, Y., & Sekarski, N. (2018) · Frontiers in Pediatrics · doi:10.3389/fped.2018.00079 · Cited by 181
Self-citationMoving Beyond the Stethoscope: Diagnostic Point-of-Care Ultrasound in Pediatric Practice
Conlon, T., Nishisaki, A., Singh, Y., Bhombal, S., Luca, D. D., Kessler, D. O., Su, E. R., Chen, A. E., & Fraga, M. V. (2019) · PEDIATRICS · doi:10.1542/peds.2019-1402 · Cited by 120
Self-citationPathophysiology and Management of Persistent Pulmonary Hypertension of the Newborn
Singh, Y., & Lakshminrusimha, S. (2021) · Clinics in Perinatology · doi:10.1016/j.clp.2021.05.009 · Cited by 98
Self-citationSingh, Y., Villaescusa, J. U., da Cruz, E. M., Tibby, S. M., Bottari, G., Saxena, R., Guillén, M., Herce, J. L., Di Nardo, M., Cecchetti, C., et al. (2020) · Critical Care · doi:10.1186/s13054-020-03326-2 · Cited by 86
Self-citation
Metadata
- Authors
- Singh, Y.
- Affiliations
- University of Cambridge (GB)
- Corresponding author
- Singh, Yogen
- ORCID
- Singh, Yogen
- Venue
- Frontiers in Pediatrics
- Publisher
- Frontiers Media SA
- Published
- 2017-09-15
- Volume
- 5
- Pages
- 201-201
- ISSN
- 2296-2360 (ISSN-L)
- PMC
- PMC5605552
- OpenAlex
- W2755816020
- Cited by
- 116
- References
- 71
- Citations by year
- 2026: 10 · 2025: 16 · 2024: 10 · 2023: 17 · 2022: 14 · 2021: 21 · 2020: 18 · 2019: 4 · 2018: 6
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- cc-by
- Locations
- Frontiers in Pediatrics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Ultrasound in Clinical Applications
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Keywords
- point-of-care echocardiography, hemodynamic assessment, neonates, critically ill children, cardiac output, preload and afterload, shock, pulmonary hypertension, patent ductus arteriosus, cardiac tamponade, pericardial effusion, congenital heart disease, fluid resuscitation, vasopressors, pulmonary vasodilators, tissue perfusion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review