Hemodynamic assessment in children after cardiac surgery: A pilot study on the value of infrared thermography
Open accessAbstract
Introduction: Low cardiac output syndrome in the postoperative period after cardiac surgery leads to an increase in tissue oxygen extraction, assessed by the oxygen extraction ratio. Measurement of the oxygen extraction ratio requires blood gases to be taken. However, the temperature of the skin and various parts of the body is a direct result of blood flow distribution and can be monitored using infrared thermography. Thus, we conducted a prospective clinical study to evaluate the correlation between the thermal gradient obtained by infrared thermography and the oxygen extraction ratio in children at risk for low cardiac output after cardiac surgery. Methods: Children aged 0 to 18 years, having undergone cardiac surgery with cardio-pulmonary bypass in a pediatric intensive care unit were included in the study. One to 4 thermal photos were taken per patient using the FLIR One Pro thermal imaging camera. The thermal gradient between the central temperature of the inner canthus of the eye and the peripheral temperature was compared to the concomitant oxygen extraction ratio calculated from blood gases. Results: 41 patients were included with a median age of 6 months (IQR 3–48) with median Risk Adjustment for Congenital Heart Surgery-1 score was 2 (IQR 2–3). Eighty nine thermal photos were analyzed. The median thermal gradient was 2.5 °C (IQR 1,01–4.04). The median oxygen extraction ratio was 35% (IQR 26–42). Nine patients had an oxygen extraction ratio ≥ 50%. A significant but weak correlation was found between the thermal gradient and the oxygen extraction ratio (Spearman's test p = 0.25, p = 0.016). Thermal gradient was not correlated with any other clinical or biologic markers of low cardiac output. Only young age was an independent factor associated with an increase in the thermal gradient. Conclusion: In this pilot study, which included mainly children without severe cardiac output decrease, a significant but weak correlation between thermal gradient by infrared thermography and oxygen extraction ratio after pediatric cardiac surgery was observed. Infrared thermography is a promising non-invasive technology that could be included in multimodal monitoring of postoperative cardiac surgery patients. However, a clinical trial including more severe children is needed.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743 · see citing works
Connors, A., Speroff, T., Dawson, N., Thomas, C. L., Harrell, F., Wagner, D., Desbiens, N., Goldman, L., Wu, A. W., Califf, R., et al. (1996) · Journal of the American Medical Association (JAMA) · doi:10.1001/jama.276.11.889 · Cited by 2,383 · see citing works
The Effectiveness of Right Heart Catheterization in the Initial Care of Critically III Patients
Connors, A. F. (1996) · JAMA · doi:10.1001/jama.1996.03540110043030 · Cited by 2,239 · see citing works
Consensus-based method for risk adjustment for surgery for congenital heart disease
Jenkins, K. J., Gauvreau, K., Newburger, J. W., Spray, T. L., Moller, J. H., & Iezzoni, L. I. (2002) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1067/mtc.2002.119064 · Cited by 1,370 · see citing works
Medical applications of infrared thermography: A review
Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J. (2012) · Infrared Physics & Technology · doi:10.1016/j.infrared.2012.03.007 · Cited by 1,359 · see citing works
Infrared thermal imaging in medicine
Ring, E. F. J., & Ammer, K. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/3/r33 · Cited by 1,037 · see citing works
Wernovsky, G., Wypij, D., Jonas, R. A., Mayer, J. E., Hanley, F. L., Hickey, P. R., Walsh, A. Z., Chang, A. C., Castañeda, A. R., Newburger, J. W., et al. (1995) · Circulation · doi:10.1161/01.cir.92.8.2226 · Cited by 1,010 · see citing works
Hoffman, T. M., Wernovsky, G., Atz, A. M., Kulik, T. J., Nelson, D. P., Chang, A. C., Bailey, J. M., Akbary, A., Kocsis, J. F., Kaczmarek, R., et al. (2003) · Circulation · doi:10.1161/01.cir.0000051365.81920.28 · Cited by 772 · see citing works
Early On–Cardiopulmonary Bypass Hypotension and Other Factors Associated With Vasoplegic Syndrome
Levin, M. A., Lin, H., Castillo, J. G., Adams, D. H., Reich, D. L., & Fischer, G. W. (2009) · Circulation · doi:10.1161/circulationaha.108.814533 · Cited by 240 · see citing works
Clinicians’ abilities to estimate cardiac index in ventilated children and infants
Tibby, S. M., Hatherill, M., Marsh, M. J., & Murdoch, I. A. (1997) · Archives of Disease in Childhood · doi:10.1136/adc.77.6.516 · Cited by 224 · see citing works
Cardiopulmonary Bypass-Induced Inflammatory Response: Pathophysiology and Treatment
Bronicki, R. A., & Hall, M. W. (2016) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000000759 · Cited by 203 · see citing works
Cerebral oxygenation measured by near-infrared spectroscopy: Comparison with jugular bulb oximetry
Daubeney, P. E. F., Pilkington, S. N., Janke, E., Charlton, G. A., Smith, D. C., & Webber, S. A. (1996) · The Annals of Thoracic Surgery · doi:10.1016/0003-4975(95)01186-2 · Cited by 176 · see citing works
Infrared Thermal Imaging for Automated Detection of Diabetic Foot Complications
van Netten, J. J., van Baal, J. G., Liu, C., van der Heijden, F., & Bus, S. A. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700504 · Cited by 164 · see citing works
Early markers of major adverse events in children after cardiac operations
Duke, T., Butt, W., South, M., & Karl, T. R. (1997) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70018-7 · Cited by 152 · see citing works
Tibby, S. M., Hatherill, M., & Murdoch, I. A. (1999) · Archives of Disease in Childhood · doi:10.1136/adc.80.2.163 · Cited by 152 · cited 1× · see citing works
“Hypothermia during CPB n (%) 7 (17) 2 (12) 5 (20) NS”
Shi, S., Zhao, Z., Liu, X., Shu, Q., Tan, L., Lin, R., Shi, Z., & Fang, X. (2008) · CHEST Journal · doi:10.1378/chest.07-2573 · Cited by 127 · see citing works
Weiß, M., Dullenkopf, A., Kolarova, A., Schulz, G., Frey, B., & Baenziger, O. (2005) · Pediatric Anesthesia · doi:10.1111/j.1460-9592.2005.01404.x · Cited by 116 · see citing works
Infrared thermal imaging of the inner canthus of the eye as an estimator of body core temperature
Teunissen, L. P. J., & Daanen, H. A. M. (2011) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2011.554595 · Cited by 59 · see citing works
Cerebral Oxygen Saturation in Children With Congenital Heart Disease and Chronic Hypoxemia
Kussman, B. D., Laussen, P. C., Benni, P. B., McGowan, F. X. J., & McElhinney, D. B. (2017) · Anesthesia & Analgesia · doi:10.1213/ane.0000000000002073 · Cited by 46 · see citing works
Ulate, K. P., Yanay, O., Jeffries, H., Baden, H., Di Gennaro, J. L., & Zimmerman, J. (2017) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000000979 · Cited by 45 · see citing works
Mottling score and skin temperature in septic shock: Relation and impact on prognosis in ICU
Ferraris, A., Bouisse, C., Mottard, N., Thiollière, F., Anselin, S., Piriou, V., & Allaouchiche, B. (2018) · PLOS ONE · doi:10.1371/journal.pone.0202329 · Cited by 45 · see citing works
Schey, B. M., Williams, D. Y., & Bucknall, T. (2010) · Heart & Lung · doi:10.1016/j.hrtlng.2009.04.002 · Cited by 40 · see citing works
Creating a High-Frequency Electronic Database in the PICU: The Perpetual Patient*
Brossier, D., Eltaani, R., Sauthier, M., Roumeliotis, N., Émériaud, G., & Jouvet, P. A. (2018) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000001460 · Cited by 34 · see citing works
Self-citationInfrared thermography in paediatrics: a narrative review of clinical use
Owen, R., & Ramlakhan, S. L. (2017) · BMJ Paediatrics Open · doi:10.1136/bmjpo-2017-000080 · Cited by 32 · see citing works
Butt, W. W., & Shann, F. A. (1991) · Anaesthesia and Intensive Care · doi:10.1177/0310057x9101900115 · Cited by 30 · see citing works
Modified ultrafiltration in paediatric cardiac surgery
Schlünzen, L., Pedersen, J., Hjortholm, K., Hansen, O. K., & Ditlevsen, E. (1998) · Perfusion · doi:10.1177/026765919801300205 · Cited by 25 · see citing works
Ryan, C. A., & Soder, C. M. (1989) · Critical Care Medicine · doi:10.1097/00003246-198907000-00008 · Cited by 23 · see citing works
Schey, B. M., Williams, D., & Bucknall, T. (2009) · Intensive & Critical Care Nursing · doi:10.1016/j.iccn.2008.05.003 · Cited by 20 · see citing works
Evaluation of Hemodynamics in Infants and Small Babies after Open Heart Surgery
Alexi-Meskhishvili, V., Popov, S., & Nikoljuk, A. (1984) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-2007-1023335 · Cited by 17 · cited 1× · see citing works
“Older studies found an increase in thermal gradient correlated with an increase in systemic vascular resistance, a decrease in cardiac output, stroke index, and urine output (7, 18, 19).”
BackgroundMurdoch, I., Qureshi, S., Mitchell, A., & Huggon, I. (1993) · Acta Paediatrica · doi:10.1111/j.1651-2227.1993.tb12556.x · Cited by 17 · see citing works
Bronicki, R. A. (2016) · Pediatric Critical Care Medicine · doi:10.1097/pcc.0000000000000779 · Cited by 12 · see citing works
Dagan, M., Butt, W. W., Millar, J., d’Udekem, Y., Thompson, J., & Namachivayam, S. P. (2018) · Heart Lung and Circulation · doi:10.1016/j.hlc.2018.11.003 · Cited by 11 · see citing works
Optical Thermography Infrastructure to Assess Thermal Distribution in Critically Ill Children
Shcherbakova, M., Noumeir, R., Levy, M., Bridier, A., Lestrade, V., & Jouvet, P. A. (2021) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2021.3136403 · Cited by 9 · see citing works
Self-citationOptical thermography infrastructure to assess thermal distribution in critically ill children
Shcherbakova, M. (2021) · Espace ÉTS (ETS) · Cited by 5 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
SwinFuSR: an image fusion-inspired model for RGB-guided thermal image super-resolution
Arnold, C., Jouvet, P. A., & Séoud, L. (2024) · IEEE/CVF Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw63382.2024.00308 · Cited by 22 · see citing works
Self-citationUses of infrared thermography in acute illness: a systematic review
Stanley, S. A., Divall, P., Thompson, J. P., & Charlton, M. (2024) · Frontiers in Medicine · doi:10.3389/fmed.2024.1412854 · Cited by 11 · see citing works
Heat for Healing: A Review of Infrared Thermography in Medical Diagnostics and Therapy
Kumar, B., Jain, V., Yadav, D. K., Dhua, A. K., Goel, P., Jain, D., & Singh, S. (2026) · Journal of Medical Physics · doi:10.4103/jmp.jmp_175_25 · Cited by 3 · see citing works
Nedelcu, C., Ionescu, N. S., Bizubac, A. M., Filip, C., & Cirstoveanu, C. (2025) · Life · doi:10.3390/life15101621 · Cited by 2 · see citing works
“Low cardiac output syndrome (LCOS) is characterized by insufficient delivery of oxygenated blood to meet the metabolic demands of tissues, leading to tissue hypoxia and metabolic acidosis [2].”
Kumar, B., Patil, N., Jain, V., Dhua, A. K., Goel, P., Yadav, D. K., Bhowmik, M. K., & Jain, D. (2026) · Journal of Indian Association of Pediatric Surgeons · doi:10.4103/jiaps.jiaps_413_25
Jouvet, P. A., Albert, K., Wiedemann, A., & Sauthier, M. (2026) · Bulletin de l Académie Nationale de Médecine · doi:10.1016/j.banm.2026.04.019
Self-citation
- Authors
- Bridier, A., Shcherbakova, M., Kawaguchi, A., Poirier, N., Said, C., Noumeir, R., & Jouvet, P.
- Affiliations
- Centre Hospitalier Universitaire Sainte-Justine (CA)
- École de Technologie Supérieure (CA)
- Tokyo Women's Medical University (JP)
- CHU Sainte-Justine Research Center (CA)
- Corresponding author
- Jouvet, Philippe
- ORCID
- Venue
- Frontiers in Pediatrics
- Publisher
- Frontiers Media SA
- Published
- 2023-04-05
- Volume
- 11
- Pages
- 1083962-1083962
- ISSN
- 2296-2360 (ISSN-L)
- PMC
- PMC10113445
- OpenAlex
- W4362625054
- Cited by
- 6
- References
- 34
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 2
- FWCI
- 0.99
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Frontiers in Pediatrics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Espace ÉTS (ETS) (submittedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
- Health Sciences › Medicine › Epidemiology › Congenital Heart Disease Studies
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- infrared thermography, low cardiac output syndrome, oxygen extraction fraction, pediatric cardiac surgery, cardiopulmonary bypass, temperature gradient, noninvasive hemodynamic monitoring, postoperative monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review