Introduction: Low cardiac output syndrome in the postoperative period after cardiac surgery leads to an increase in tissue oxygen extraction, assessed by the oxygen extraction ratio. Measurement of the oxygen extraction ratio requires blood gases to be taken. However, the temperature of the skin and various parts of the body is a direct result of blood flow distribution and can be monitored using infrared thermography. Thus, we conducted a prospective clinical study to evaluate the correlation between the thermal gradient obtained by infrared thermography and the oxygen extraction ratio in children at risk for low cardiac output after cardiac surgery. Methods: Children aged 0 to 18 years, having undergone cardiac surgery with cardio-pulmonary bypass in a pediatric intensive care unit were included in the study. One to 4 thermal photos were taken per patient using the FLIR One Pro thermal imaging camera. The thermal gradient between the central temperature of the inner canthus of the eye and the peripheral temperature was compared to the concomitant oxygen extraction ratio calculated from blood gases. Results: 41 patients were included with a median age of 6 months (IQR 3–48) with median Risk Adjustment for Congenital Heart Surgery-1 score was 2 (IQR 2–3). Eighty nine thermal photos were analyzed. The median thermal gradient was 2.5 °C (IQR 1,01–4.04). The median oxygen extraction ratio was 35% (IQR 26–42). Nine patients had an oxygen extraction ratio ≥ 50%. A significant but weak correlation was found between the thermal gradient and the oxygen extraction ratio (Spearman's test p = 0.25, p = 0.016). Thermal gradient was not correlated with any other clinical or biologic markers of low cardiac output. Only young age was an independent factor associated with an increase in the thermal gradient. Conclusion: In this pilot study, which included mainly children without severe cardiac output decrease, a significant but weak correlation between thermal gradient by infrared thermography and oxygen extraction ratio after pediatric cardiac surgery was observed. Infrared thermography is a promising non-invasive technology that could be included in multimodal monitoring of postoperative cardiac surgery patients. However, a clinical trial including more severe children is needed.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fped.2023.1083962

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Bridier, A., Shcherbakova, M., Kawaguchi, A., Poirier, N., Said, C., Noumeir, R., & Jouvet, P.
Affiliations
  • Centre Hospitalier Universitaire Sainte-Justine (CA)
  • École de Technologie Supérieure (CA)
  • Tokyo Women's Medical University (JP)
  • CHU Sainte-Justine Research Center (CA)
Corresponding author
Jouvet, Philippe
Venue
Frontiers in Pediatrics
Published
2023-04-05
Volume
11
Pages
1083962-1083962
ISSN
2296-2360 (ISSN-L)
OpenAlex
W4362625054
Cited by
6
References
34
Citations by year
2026: 3 · 2025: 1 · 2024: 2
FWCI
0.99
Type
journal article
Language
en
Open access
Locations
  • Frontiers in Pediatrics (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Espace ÉTS (ETS) (submittedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Infrared Thermography in Medicine
  • Health Sciences › Medicine › Epidemiology › Congenital Heart Disease Studies
  • Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
Keywords
infrared thermography, low cardiac output syndrome, oxygen extraction fraction, pediatric cardiac surgery, cardiopulmonary bypass, temperature gradient, noninvasive hemodynamic monitoring, postoperative monitoring

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review