CoChat

A Review of Closed-Loop Algorithms for Glycemic Control in the Treatment of Type 1 Diabetes

Open access
El Youssef, Joseph, Castle, Jessica, Ward, W. Kenneth · 2009 · Algorithms
Cited by 69

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

With the discovery of insulin came a deeper understanding of therapeutic options for one of the most devastating chronic diseases of the modern era, diabetes mellitus. The use of insulin in the treatment of diabetes, especially in those with severe insulin deficiency (type 1 diabetes), with multiple injections or continuous subcutaneous infusion, has been largely successful, but the risk for short term and long term complications remains substantial. Insulin treatment decisions are based on the patient’s knowledge of meal size, exercise plans and the intermittent knowledge of blood glucose values. As such, these are open loop methods that require human input. The idea of closed loop control of diabetes treatment is quite different: automated control of a device that delivers insulin (and possibly glucagon or other medications) and is based on continuous or very frequent glucose measurements. Closed loop insulin control for type 1 diabetes is not new but is far from optimized. The goal of such a system is to avoid short-term complications (hypoglycemia) and long-term complications (diseases of the eyes, kidneys, nerves and cardiovascular system) by mimicking the normal insulin secretion pattern of the pancreatic beta cell. A control system for automated diabetes treatment consists of three major components, (1) a glucose sensing device that serves as the afferent limb of the system; (2) an automated control unit that uses algorithms which acquires sensor input and generates treatment outputs; and (3) a drug delivery device (primarily for delivery of insulin), which serves as the system’s efferent limb. There are several major issues that highlight the difficulty of interacting with the complex unknowns of the biological world. For example, development of accurate continuous glucose monitors is crucial; the state of the art in 2009 is that such devices sometimes experience drift and are intended only to supplement information received from standard intermittent blood glucose data. In addition, it is important to acknowledge that an “automated” closed loop pancreas cannot approach the complexity of the normal human endocrine pancreas, which takes continuous data from substrates, hormones, paracrine compounds and autonomic neural inputs, and in response, secretes four hormones. Another major issue is the substantial absorption/action delay of insulin given by the subcutaneous route. Because of this delay, some researchers have recently given a portion of the meal-related insulin in an open loop manner before the meal and found this hybrid approach to be superior to closed loop control. Proportional-Integral-Derivative (PID) systems adapted from the industrial sector utilize control algorithms that alter output based on proportional (difference between actual and target levels), derivative (rate of change) and integral (time-related summative) errors in glucose. These algorithms have proven to be very promising in limited clinical trials. Related algorithms include a “fading memory” system that combines the proportional-derivative components of a classic PID system with time-relating decay of input signals that allow greater emphasis on more recent glucose values, a characteristic noted in mammalian beta-cells. Model Predictive Control (MPC) systems are highly adaptive methods that utilize mathematical models based on observations of biological behavior patterns using system identification and are now undergoing testing in humans. The application of further mathematical models, such as fuzzy control and artificial neural networks, are also promising, but are largely clinically untested. In summary, the prospects for closed loop control of glycemia in persons with diabetes have improved considerably. Major limitations include the delayed absorption/action of subcutaneous insulin and the imperfect stability of currently-available continuous glucose sensors. The potential for improved glycemic control in persons with diabetes brings with it the potential for reduction in the frequency of acute and chronic complications of diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/a2010518

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 69

Metadata

Authors
El Youssef, J., Castle, J., & Ward, W. K.
Venue
Algorithms
Publisher
MDPI AG
Published
2009-03-12
Volume
2
Issue
1
Pages
518-532
ISSN
1999-4893 (ISSN-L)
OpenAlex
W2148076948
Cited by
69
References
12
FWCI
5.22
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Review of Closed-Loop Algorithms for Glycemic Control in the Treatment of Type 1 Diabetes. https://app.cochat.ai/papers/10.3390/a2010518
The paper
El Youssef, J., Castle, J., & Ward, W. K. (2009). A Review of Closed-Loop Algorithms for Glycemic Control in the Treatment of Type 1 Diabetes. Algorithms. https://doi.org/10.3390/a2010518

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.