Exposure to Particle Matters and Hazardous Volatile Organic Compounds in Selected Hot Spring Hotels in Guangdong, China
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
In Guangdong province, many hot springs were exploited and developed into popular places for tourist. In addition, hotels have been set up near hot spring sites to attract people, including local citizens, to spend their spare time inside these so-called “spring hotels”. In our study, indoor air quality was investigated in four hot spring hotels in Guangdong province, China. Measured indoor pollutants included CO2, CO, PM10, PM2.5 and Volatile Organic Compounds (VOCs). As the result show, high concentrations of carbon dioxide might be attributed to poor ventilation; and the variations of indoor PM10, PM2.5 concentrations were related to occupants’ activities. Alpha-pinene and toluene were the most common VOC species in the hot spring hotels other than monocyclic aromatic hydrocarbons like Benzene, Toluene, Ethylbenzene and Xylenes (BTEX), which were at medium levels among the reported indoor pollutants. High cancer risk of benzene in the newly decorated rooms should be seriously taken into consideration in the future. Indoor to Outdoor air concentration ratios (I/O) for CO2 and VOCs were higher than 1, indicating their strong indoor sources. Negative correlations were found between indoor CO2 and all the other compounds, and VOCs were shown to be significantly correlated (p < 0.01) to each other, including aromatic hydrocarbons and mono-terpenes. For indoor and outdoor air compounds, correlation coefficients among all compounds did not show a significant correlation, which indicated that these pollutants had different sources. Principal components analysis by SPSS showed that indoor materials, inhabitants’ activities and respiration, cleaning products and outdoor sources were the main sources of indoor detected pollutants in hot spring hotels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Several studies conducted in industrial areas in China have reported high indoor BTEX and TTVOC levels (even though relatively few target VOCs were included) as well as high outdoor levels (averaging 420 μg/m3) [22–24].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [24]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zou, Y., Deng, X. J., Zhu, D., Gong, D. C., Wang, H., Li, F., Tan, H. B., Deng, T., Mai, B. R., Liu, X. T., et al. (2015) · Atmospheric Chemistry and Physics · doi:10.5194/acp-15-6625-2015 · Cited by 283
Massey, D., Kulshrestha, A., Masih, J., & Taneja, A. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.07.018 · Cited by 261 · cited 1×
“121 mg ̈m ́3) in spring hotels were higher than in residential rooms, station waiting rooms, offices, supermarkets and classrooms, but lower than commercial offices [4,10,27,29,30].”
Persily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249 · cited 1×
“Previous studies showed that indoor CO2 concentrations were similar to and higher than the American Society of Heating and Refrigerating and Air-conditioning Engineers (ASHRAE) Standard of 1000 ppm [24], depending on both internal sources and external background concentration, coupled with low air exchange rate [4,5].”
Source apportionment of indoor and outdoor volatile organic compounds at homes in Edmonton, Canada
Bari, M. A., Kindzierski, W. B., Wheeler, A. J., Héroux, M.-È., & Wallace, L. A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.023 · Cited by 208 · cited 5×
“The detected levels of indoor air pollutants like some Volatile Organic Compound (VOC) species, CO2, and particulate matter often exceed outdoor levels by up to 5 times [1,2], and most individuals spend most of their time in indoor environments [3].”
InfluentialIndoor air quality and comfort in seven newly built, energy-efficient houses in France
Derbez, M., Berthineau, B., Cochet, V., Lethrosne, M., Pignon, C., Riberon, J., & Kirchner, S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.10.017 · Cited by 168
Ohura, T., Amagai, T., Shen, X., Li, S., Zhang, P., & Zhu, L. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.09.022 · Cited by 162 · cited 3×
“Fac or 2 was associated with b zene, toluene, styrene, 1,3,5-TMB, and beta-pinene, which oul be c nsidered as outdoor sources, such as traffic emission a biogenic emission [11].”
InfluentialIndoor airborne particle sources and semi-volatile partitioning effect of outdoor fine PM in offices
Sangiorgi, G., Ferrero, L., Ferrini, B., Porto, C. L., Perrone, M., Zangrando, R., Gambaro, A., Lazzati, Z., & Bolzacchini, E. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.10.050 · Cited by 146 · cited 1×
“121 mg ̈m ́3) in spring hotels were higher than in residential rooms, station waiting rooms, offices, supermarkets and classrooms, but lower than commercial offices [4,10,27,29,30].”
Kumar, A., Singh, B. P., Punia, M., Singh, D., Kumar, K., & Jain, V. K. (2013) · Environmental Science and Pollution Research · doi:10.1007/s11356-013-2150-7 · Cited by 124 · cited 6×
“The detected levels of indoor air pollutants like some Volatile Organic Compound (VOC) species, CO2, and particulate matter often exceed outdoor levels by up to 5 times [1,2], and most individuals spend most of their time in indoor environments [3].”
MethodInfluentialSecondary organic aerosol formation from hydroxyl radical oxidation and ozonolysis of monoterpenes
Zhao, D., Kaminski, M., Schlag, P., Fuchs, H., Acır, I.-H., Bohn, B., Häseler, R., Kiendler‐Scharr, A., Röhrer, F., Tillmann, R., et al. (2015) · Atmospheric chemistry and physics · doi:10.5194/acp-15-991-2015 · Cited by 123 · cited 1×
“Monoterpenes are highly reactive and easily undergo free-radical addition with O3 or degrade by photochemical reactions, yielding low volatility compounds that readily form organic secondary aerosols [35].”
Madureira, J., Paciência, I., Rufo, J. C., Severo, M., Ramos, E., Barros, H., & Fernandes, E. D. O. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.11.031 · Cited by 123
Cited by
Zhang, H., & Srinivasan, R. S. (2020) · Sustainability · doi:10.3390/su12219045 · Cited by 190
“5 and BC were strongly related to the outdoor value; PM increased in all particle sizes He et al., 2016 [221] Guangdong, China Hotel buildings CO2; CO; PM10, PM2.”
BackgroundLin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S. (2021) · Indoor Air · doi:10.1111/ina.12709 · Cited by 59
“19-21 Volatile organic compound levels in hotels have been reported in a few studies, 22-24 but information regarding inhalation exposure of hotel workers is missing.”
Morillas, H., Marcaida, I., Maguregui, M., Upasen, S., Gallego‐Cartagena, E., & Madariaga, J. M. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.04.063 · Cited by 53
Outdoor benzene highly impacts indoor concentrations globally
Liu, C., Huang, X., & Li, J. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.137640 · Cited by 54
Pytel, K., Marcinkowska, R., Rutkowska, M., & Zabiegała, B. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.156948 · Cited by 30
Exploring particulate matter pollution in hotel guestrooms
Chang, H. “., Huh, C., Legendre, T. S., & Simpson, J. J. (2020) · International Journal of Contemporary Hospitality Management · doi:10.1108/ijchm-05-2019-0481 · Cited by 15
Abiye, O. E., Akinola, O. E., Sunmonu, L. A., Ajao, A., & Ayoola, M. A. (2016) · African Journal of Environmental Science and Technology · doi:10.5897/ajest2016.2128 · Cited by 11
“This can be attributed to the increased occurrence of calm conditions resulting in poor ventilation (He et al., 2016).”
BackgroundIndoor air quality monitoring and management in hospitality: an overarching framework
Zanni, S., Mura, M., Longo, M., Motta, G., & Caiulo, D. (2022) · International Journal of Contemporary Hospitality Management · doi:10.1108/ijchm-12-2021-1549 · Cited by 10
Nored, A. W., Fu, X., Qi, R., Batbaatar, N., & Jia, C. (2024) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph21111464 · Cited by 11
“A pre-pandemic IAQ study involving four hotels reported that outside sources and indoor cleaning agents were the main contributors to indoor VOCs [22].”
Yin, T., Gao, W., Wei, X., Wu, L., & Wang, C. (2024) · Indoor and Built Environment · doi:10.1177/1420326x241280680 · Cited by 7
Solvent-Free Toner Printing of Organic Semiconductor Layer in Flexible Thin-Film Transistors
Sakai, M., Koh, T., Toyoshima, K., Nakamori, K., Okada, Y., Yamauchi, H., Sadamitsu, Y., Shinamura, S., & Kudo, K. (2017) · Physical Review Applied · doi:10.1103/physrevapplied.8.014001 · Cited by 7
Managing the invisible: the role of air quality in the hospitality industry
Zanni, S., Mura, M., & Longo, M. (2025) · International Journal of Contemporary Hospitality Management · doi:10.1108/ijchm-10-2024-1504 · Cited by 3
Liu, J., Zhang, Z., Yang, Y., Wang, J., Song, J., Jing, L., Li, J., & Zhang, H. (2026) · Air Quality Atmosphere & Health · doi:10.1007/s11869-026-01985-8
Yin, T. (n.d.) · Institutional Repositories DataBase (IRDB)
Metadata
- Authors
- He, Q., Song, Q., Yan, Y., Wang, Z., Guo, L., & Wang, X.
- Affiliations
- Taiyuan University of Science and Technology (CN)
- Guangdong Meteorological Observatory, Guangzhou 510080, China
- Chinese Academy of Sciences (CN)
- Corresponding author
- He, Qiusheng
- Venue
- Atmosphere
- Publisher
- MDPI AG
- Published
- 2016-04-11
- Volume
- 7
- Issue
- 4
- Pages
- 54
- ISSN
- 2073-4433 (ISSN-L)
- OpenAlex
- W2333654140
- Cited by
- 13
- References
- 35
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2022: 2 · 2020: 4 · 2019: 1 · 2017: 1 · 2016: 1
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Atmosphere (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (41472311, 41172316)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor air quality, volatile organic compounds, particulate matter, carbon dioxide, carbon monoxide, PM2.5, PM10, α-pinene, toluene, BTEX, cancer risk, Guangdong
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.