Exposure to Particle Matters and Hazardous Volatile Organic Compounds in Selected Hot Spring Hotels in Guangdong, China
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
In Guangdong province, many hot springs were exploited and developed into popular places for tourist. In addition, hotels have been set up near hot spring sites to attract people, including local citizens, to spend their spare time inside these so-called “spring hotels”. In our study, indoor air quality was investigated in four hot spring hotels in Guangdong province, China. Measured indoor pollutants included CO2, CO, PM10, PM2.5 and Volatile Organic Compounds (VOCs). As the result show, high concentrations of carbon dioxide might be attributed to poor ventilation; and the variations of indoor PM10, PM2.5 concentrations were related to occupants’ activities. Alpha-pinene and toluene were the most common VOC species in the hot spring hotels other than monocyclic aromatic hydrocarbons like Benzene, Toluene, Ethylbenzene and Xylenes (BTEX), which were at medium levels among the reported indoor pollutants. High cancer risk of benzene in the newly decorated rooms should be seriously taken into consideration in the future. Indoor to Outdoor air concentration ratios (I/O) for CO2 and VOCs were higher than 1, indicating their strong indoor sources. Negative correlations were found between indoor CO2 and all the other compounds, and VOCs were shown to be significantly correlated (p < 0.01) to each other, including aromatic hydrocarbons and mono-terpenes. For indoor and outdoor air compounds, correlation coefficients among all compounds did not show a significant correlation, which indicated that these pollutants had different sources. Principal components analysis by SPSS showed that indoor materials, inhabitants’ activities and respiration, cleaning products and outdoor sources were the main sources of indoor detected pollutants in hot spring hotels.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Several studies conducted in industrial areas in China have reported high indoor BTEX and TTVOC levels (even though relatively few target VOCs were included) as well as high outdoor levels (averaging 420 μg/m3) [22–24].”
From Occupational exposure and health risks of volatile organic compounds of hotel housekeepers: Field measurements of exposure and health risks (2021) · cites this paper as [24]
Citations
Cites
Zou, Y., Deng, X. J., Zhu, D., Gong, D. C., Wang, H., Li, F., Tan, H. B., Deng, T., Mai, B. R., Liu, X. T., et al. (2015) · Atmospheric Chemistry and Physics · doi:10.5194/acp-15-6625-2015 · Cited by 283
Massey, D., Kulshrestha, A., Masih, J., & Taneja, A. (2012) · Building and Environment · doi:10.1016/j.buildenv.2011.07.018 · Cited by 261 · cited 1×
“121 mg ̈m ́3) in spring hotels were higher than in residential rooms, station waiting rooms, offices, supermarkets and classrooms, but lower than commercial offices [4,10,27,29,30].”
Persily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249 · cited 1×
“Previous studies showed that indoor CO2 concentrations were similar to and higher than the American Society of Heating and Refrigerating and Air-conditioning Engineers (ASHRAE) Standard of 1000 ppm [24], depending on both internal sources and external background concentration, coupled with low air exchange rate [4,5].”
Source apportionment of indoor and outdoor volatile organic compounds at homes in Edmonton, Canada
Bari, M. A., Kindzierski, W. B., Wheeler, A. J., Héroux, M.-È., & Wallace, L. A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.023 · Cited by 208 · cited 5×
“The detected levels of indoor air pollutants like some Volatile Organic Compound (VOC) species, CO2, and particulate matter often exceed outdoor levels by up to 5 times [1,2], and most individuals spend most of their time in indoor environments [3].”
InfluentialIndoor air quality and comfort in seven newly built, energy-efficient houses in France
Derbez, M., Berthineau, B., Cochet, V., Lethrosne, M., Pignon, C., Riberon, J., & Kirchner, S. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.10.017 · Cited by 168
Ohura, T., Amagai, T., Shen, X., Li, S., Zhang, P., & Zhu, L. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2009.09.022 · Cited by 162 · cited 3×
“Fac or 2 was associated with b zene, toluene, styrene, 1,3,5-TMB, and beta-pinene, which oul be c nsidered as outdoor sources, such as traffic emission a biogenic emission [11].”
InfluentialIndoor airborne particle sources and semi-volatile partitioning effect of outdoor fine PM in offices
Sangiorgi, G., Ferrero, L., Ferrini, B., Porto, C. L., Perrone, M., Zangrando, R., Gambaro, A., Lazzati, Z., & Bolzacchini, E. (2012) · Atmospheric Environment · doi:10.1016/j.atmosenv.2012.10.050 · Cited by 146 · cited 1×
“121 mg ̈m ́3) in spring hotels were higher than in residential rooms, station waiting rooms, offices, supermarkets and classrooms, but lower than commercial offices [4,10,27,29,30].”
Kumar, A., Singh, B. P., Punia, M., Singh, D., Kumar, K., & Jain, V. K. (2013) · Environmental Science and Pollution Research · doi:10.1007/s11356-013-2150-7 · Cited by 124 · cited 6×
“The detected levels of indoor air pollutants like some Volatile Organic Compound (VOC) species, CO2, and particulate matter often exceed outdoor levels by up to 5 times [1,2], and most individuals spend most of their time in indoor environments [3].”
MethodInfluentialSecondary organic aerosol formation from hydroxyl radical oxidation and ozonolysis of monoterpenes
Zhao, D., Kaminski, M., Schlag, P., Fuchs, H., Acır, I.-H., Bohn, B., Häseler, R., Kiendler‐Scharr, A., Röhrer, F., Tillmann, R., et al. (2015) · Atmospheric chemistry and physics · doi:10.5194/acp-15-991-2015 · Cited by 123 · cited 1×
“Monoterpenes are highly reactive and easily undergo free-radical addition with O3 or degrade by photochemical reactions, yielding low volatility compounds that readily form organic secondary aerosols [35].”
Madureira, J., Paciência, I., Rufo, J. C., Severo, M., Ramos, E., Barros, H., & Fernandes, E. D. O. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.11.031 · Cited by 123
Ou, J., Guo, H. F., Zheng, J., Cheung, K., Louie, P. K. K., Ling, Z., & Wang, D. (2014) · Atmospheric Environment · doi:10.1016/j.atmosenv.2014.12.048 · Cited by 97 · cited 2×
“In the corresponding outdoor air, BTEX concentrations were slightly less than those of the indoor air, and much lower than those of urban air like Guangzhou, Hong Kong [20,21].”
Monitoring of volatile organic compounds in non-residential indoor environments
Bruno, P., Caselli, M., de Gennaro, G., Iacobellis, S., & Tutino, M. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00528.x · Cited by 92 · cited 6×
“Mono-terpenes, highly reactive kinds of VOCs, could result in secondary pollution in indoor microenvironments, and originate mainly from cleaning products, personal hygiene articles and building sources [13,16].”
InfluentialConcentration of particulate matter, CO and CO2 in selected schools in Malaysia
Razali, N. Y. Y., Latif, M. T., Dominick, D., Mohamad, N., Sulaiman, F. R., & Srithawirat, T. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.01.015 · Cited by 90 · cited 8×
“121 mg ̈m ́3) in spring hotels were higher than in residential rooms, station waiting rooms, offices, supermarkets and classrooms, but lower than commercial offices [4,10,27,29,30].”
InfluentialA Review of CO 2 Measurement Procedures in Ventilation Research
Mahyuddin, N., & Awbi, H. (2012) · International Journal of Ventilation · doi:10.1080/14733315.2012.11683961 · Cited by 73 · cited 1×
“The CO2 concentration is widely used as an indicator of indoor ventilation effectiveness, and high CO2 values in the spring hotels indicated insufficient ventilation [6].”
de Gennaro, G., de Gennaro, L., Mazzone, A., Porcelli, F., & Tutino, M. (2013) · Atmospheric Environment · doi:10.1016/j.atmosenv.2013.10.056 · Cited by 61 · cited 1×
“In this study, the LCRs of most compounds were less than 10 ́6, suggesting exposure safety at the current levels [38].”
Indoor/Outdoor Relationships between PM10 and Associated Organic Compounds in a Primary School
Alves, C. A., Urban, R. C., Pegas, P. N., & Nunes, T. (2014) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2013.04.0114 · Cited by 60 · cited 1×
“This was strongly related to the activities and movement of the occupants, which led to re-suspension of previously deposited particles or their delayed deposition or settling [31].”
Indoor air quality in new hotels’ guest rooms of the major world factory region
Chan, W., Lee, S.-C., Chen, Y., Mak, B., Wong, K., Chan, C.-S., Zheng, C., & Guo, X. (2009) · International Journal of Hospitality Management · doi:10.1016/j.ijhm.2008.03.004 · Cited by 55 · cited 1×
“The difference in pollutants levels between hot spring hotel rooms and previously reported rooms was due to the decoration and furniture materials used in the room, and high toluene levels were found in Hotel 1 in southern China due to the usage of poor quality carpet fitted in the room [12,15,33].”
Yang, W.-B., Chen, W., Yuan, C., Yang, J.-C., & Zhao, Q. (2012) · Journal of Environmental Monitoring · doi:10.1039/c2em30138e · Cited by 47 · cited 1×
“The cancer risks were calculated using Equations (1) and (2) based on the exposure to benzene from inhalation [3,36].”
MethodChang, S. Y., Chou, C. C. ‐., Liu, S. C., & Zhang, Y. (2013) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2012.09.0253 · Cited by 44 · cited 1×
“5 outside spring hotels were lower than those reported in urban area of the PRD like Hong Kong and Guangzhou because they were in rural areas and there was a low density of human activities nearby [18,19].”
Amodio, M., Dambruoso, P. R., de Gennaro, G., de Gennaro, L., Loiotile, A. D., Marzocca, A., Stasi, F., de Trizio, L., & Tutino, M. (2014) · Environmental Science and Pollution Research · doi:10.1007/s11356-014-2544-1 · Cited by 40
Carbonyl compounds and BTEX in the special rooms of hospital in Guangzhou, China
Lü, H., Cai, Q.-Y., Wen, S., Chi, Y., Guo, S., Sheng, G., Fu, J., & Katsoyiannis, A. A. (2010) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2010.01.138 · Cited by 40 · cited 1×
“BTEX pollutions in spring hotels were at the middle level among the reported sites, higher than offices and primary schools, and lower than a photocopy shop, drugstore, schoolroom, hospital, hotel and hotel guest rooms [1–3,12,15,32,33].”
Indoor–outdoor behavior and sources of size-resolved airborne particles in French classrooms
Tran, D.-T., Alleman, L., Coddeville, P., & Galloo, J.-C. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.06.023 · Cited by 38 · cited 1×
“The mean concentration of CO2 (1319 ppm) was higher in the spring hotels than some indoor microenvironments, like schools (502 ppm [4]; 1216 ppm [23]).”
Cometto‐Muñiz, J. E., & Abraham, M. H. (2015) · Chemosphere · doi:10.1016/j.chemosphere.2014.12.089 · Cited by 35 · cited 1×
“High indoor levels of alpha-pinene and 1-limonene could also be found in some previous studies, like restaurants and supermarkets [13,34].”
Cheng, Y., Chang, H.-P., & Yan, J.-W. (2012) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2011.06.0085 · Cited by 30 · cited 1×
“121 mg ̈m ́3) in spring hotels were higher than in residential rooms, station waiting rooms, offices, supermarkets and classrooms, but lower than commercial offices [4,10,27,29,30].”
Characterisation of Volatile Organic Compounds at Hotels in Southern China
Chan, C. S., Lee, S. C., Chan, W., Ho, K. F., Tian, L., Lai, S. C., Li, Y. S., & Huang, Y. (2011) · Indoor and Built Environment · doi:10.1177/1420326x11409458 · Cited by 25
Wang, Y., Li, J., Cheng, X., Lun, X., Sun, D., & Wang, X. (2014) · Journal of Environmental Sciences · doi:10.1016/s1001-0742(13)60398-8 · Cited by 21 · cited 1×
“5 outside spring hotels were lower than those reported in urban area of the PRD like Hong Kong and Guangzhou because they were in rural areas and there was a low density of human activities nearby [18,19].”
Self-citationResidential indoor and personal PM10 exposures of ambient origin based on chemical components
Xu, J., Bai, Z., You, Y., Zhou, J., Zhang, J., Niu, C., Liu, Y., Zhang, N., He, F., & Ding, X. (2014) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2014.28 · Cited by 20 · cited 4×
“house work) and some other sources [1,9–12].”
InfluentialSource apportionment of indoor PM10 in Elderly Care Centre
Almeida-Silva, M., Faria, T., Saraga, D. E., Maggos, T., Wolterbeek, H. T., & Almeida, S. M. (2016) · Environmental Science and Pollution Research · doi:10.1007/s11356-015-5937-x · Cited by 18 · cited 2×
“135 mg ̈m ́3) in spring hotels was higher than that in schoolrooms, residential rooms, office buildings, care centers and station waiting rooms [4,9,26–28].”
Environmental Epidemiology: Principles and Methods
Merrill, R. M. (2009) · Cited by 16
Dong, C., Yang, L., Yan, C., Yuan, Q., Yu, Y., & Wang, W. (2012) · Frontiers of Environmental Science & Engineering · doi:10.1007/s11783-012-0411-1 · Cited by 16 · cited 4×
“074 Supermarket [10] 0.”
InfluentialOh, J. H., Jeong, N.-N., Chi, W.-B., Seo, J., Jun, S.-M., & Sohn, J. (2015) · Environmental Science and Pollution Research · doi:10.1007/s11356-015-4810-2 · Cited by 13 · cited 2×
“022 Office Building [28] 0.”
Dong, Lingxiao, Yang, et al. (2013) · 中国环境科学与工程前沿:英文版 · Cited by 8
ASHRAE 62-1999 ventilation for acceptable indoor air quality, addendum n.
Burton, D. J. (2000) · PubMed · Cited by 3
Studies on PM_(10),PM_(2.5),CO_2 and ~(222)Rn in the hot spring hotel rooms
Wang, X. (2004) · China Environmental Science · Cited by 2
Self-citationStudies on PM_(10),PM_(2.5),CO_2 and ~(222)Rn in the hot spring hotel rooms
宋刚, Wang, X., 张伯友, & 何秋生 (2004) · China Environmental Science · Cited by 2
Self-citationSources and health risk assessment of aromatic hydrocarbons in the indoor of Guangzhou hotels
Cao, X. (2012) · China Environmental Science · Cited by 1
Research works printed but not linked: 2
- Mahyuddin, 2012, A review of CO2 measurement procedures in ventilation research, Int. J. Vent., 10, 353
- Song, 2004, Studies on PM10, PM2.5, CO2 and 222Rn in the hot spring hotel rooms, China Environ. Sci., 24, 650
Cited by
Zhang, H., & Srinivasan, R. S. (2020) · Sustainability · doi:10.3390/su12219045 · Cited by 189
“5 and BC were strongly related to the outdoor value; PM increased in all particle sizes He et al., 2016 [221] Guangdong, China Hotel buildings CO2; CO; PM10, PM2.”
BackgroundLin, N., Rosemberg, M., Li, W., Meza‐Wilson, E., Godwin, C., & Batterman, S. (2021) · Indoor Air · doi:10.1111/ina.12709 · Cited by 59
“19-21 Volatile organic compound levels in hotels have been reported in a few studies, 22-24 but information regarding inhalation exposure of hotel workers is missing.”
Morillas, H., Marcaida, I., Maguregui, M., Upasen, S., Gallego‐Cartagena, E., & Madariaga, J. M. (2019) · Journal of Cleaner Production · doi:10.1016/j.jclepro.2019.04.063 · Cited by 53
Outdoor benzene highly impacts indoor concentrations globally
Liu, C., Huang, X., & Li, J. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.137640 · Cited by 54
Pytel, K., Marcinkowska, R., Rutkowska, M., & Zabiegała, B. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.156948 · Cited by 30
Metadata
- Authors
- He, Q., Song, Q., Yan, Y., Wang, Z., Guo, L., & Wang, X.
- Affiliations
- Taiyuan University of Science and Technology (CN)
- Guangdong Meteorological Observatory, Guangzhou 510080, China
- Chinese Academy of Sciences (CN)
- Corresponding author
- He, Qiusheng
- Venue
- Atmosphere
- Publisher
- MDPI AG
- Published
- 2016-04-11
- Volume
- 7
- Issue
- 4
- Pages
- 54
- ISSN
- 2073-4433 (ISSN-L)
- OpenAlex
- W2333654140
- Cited by
- 13
- References
- 35
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 2 · 2022: 2 · 2020: 4 · 2019: 1 · 2017: 1 · 2016: 1
- FWCI
- 0.63
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Atmosphere (publishedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Natural Science Foundation of China (41472311, 41172316)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Air Quality and Health Impacts
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- indoor air quality, volatile organic compounds, particulate matter, carbon dioxide, carbon monoxide, PM2.5, PM10, α-pinene, toluene, BTEX, cancer risk, Guangdong
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.