Use of Hydrogen Peroxide Vapour for Microbiological Disinfection in Hospital Environments: A Review
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Disinfection of nosocomial pathogens in hospitals is crucial to combat healthcare-acquired infections, which can be acquired by patients, visitors and healthcare workers. However, the presence of a wide range of pathogens and biofilms, combined with the indiscriminate use of antibiotics, presents infection control teams in healthcare facilities with ongoing challenges in the selection of biocides and application methods. This necessitates the development of biocides and innovative disinfection methods that overcome the shortcomings of conventional methods. This comprehensive review finds the use of hydrogen peroxide vapour to be a superior alternative to conventional methods. Motivated by observations in previous studies, herein, we provide a comprehensive overview on the utilisation of hydrogen peroxide vapour as a superior high-level disinfection alternative in hospital settings. This review finds hydrogen peroxide vapour to be very close to an ideal disinfectant due to its proven efficacy against a wide range of microorganisms, safety to use, lack of toxicity concerns and good material compatibility. The superiority of hydrogen peroxide vapour was recently demonstrated in the case of decontamination of N95/FFP2 masks for reuse to address the critical shortage caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) during the COVID-19 pandemic. Despite the significant number of studies demonstrating antimicrobial activity, there remains a need to critically understand the mechanism of action by performing studies that simultaneously measure damage to all bacterial cell components and assess the correlation of this damage with a reduction in viable cell count. This can lead to improvement in antimicrobial efficacy and foster the development of superior approaches.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“HPV systems, in particular, have emerged as a powerful tool, capable of penetrating biofilm structures and eradicating embedded pathogens through the generation of ROS.”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [370]
In the citing paper
“These approaches have demonstrated efficacy in decreasing the occurrence of HAIs and MDROs [369,370].”
From Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts (2025) · cites this paper as [370]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
First hospital outbreak of the globally emerging Candida auris in a European hospital
Schelenz, S., Hagen, F., Rhodes, J. L., Abdolrasouli, A., Chowdhary, A., Hall, A., Ryan, L., Shackleton, J., Trimlett, R., Meis, J. F., et al. (2016) · Antimicrobial Resistance & Infection Control · doi:10.1186/s13756-016-0132-5 · Cited by 768 · cited 2×
“The authors [90] demonstrated a successful outcome through the use of a new infection control method that applied a high-strength chlorine-based agent, followed by hydrogen peroxide vaporisation.”
Cosmetics preservation: a review on present strategies
Halla, N., Fernandes, I. P., Heleno, S. A., Costa, P., Boucherit-Otmani, Z., Boucherit, K., Rodrigues, A. E., Ferreira, I. C. F. R., & Barreiro, M. F. (2018) · Molecules · doi:10.3390/molecules23071571 · Cited by 401
Current and emergent strategies for disinfection of hospital environments
Abreu, A. C., Tavares, R. R., Borges, A., Mergulhao, F., & Simoes, M. (2013) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkt281 · Cited by 235 · cited 1×
“For example, Escherichia coli ( E. coli ) can survive on dry inanimate surfaces from 1.5 h to 16 months, while Clostridium difficile ( C. difficile ) can survive on dry inanimate surfaces and hospital floors for a period of up to 5 months [10,12].”
InfluentialAbdolrasouli, A., Armstrong‐James, D., Ryan, L., & Schelenz, S. (2017) · Mycoses · doi:10.1111/myc.12699 · Cited by 150
Williams, G. J., Denyer, S. P., Hosein, I. K., Hill, D. W., & Maillard, J.-Y. (2007) · Journal of Hospital Infection · doi:10.1016/j.jhin.2007.08.012 · Cited by 57 · cited 1×
“Furthermore, not all disinfection methods are seen to be effective [19–21]; in fact, in one investigation, ready-to-use antibacterial wipes were observed to act as pathogen spreaders instead of eradicating pathogens [22].”
Research works printed but not linked: 92
- Rutala, 1999, Infection control: The role of disinfection and sterilization, J. Hosp. Infect., 43, S43, 10.1016/S0195-6701(99)90065-8 · DOI · Paper page
- Haque, 2018, Health care-associated infections—An overview, Infect. Drug Resist., 11, 2321, 10.2147/IDR.S177247 · DOI · Paper page
- Stone, 2009, Economic burden of healthcare-associated infections: An American perspective, Expert. Rev. Pharmacoecon Outcomes Res., 9, 417, 10.1586/erp.09.53 · DOI · Paper page
- Talon, 1999, The role of the hospital environment in the epidemiology of multi-resistant bacteria, J. Hosp. Infect., 43, 13, 10.1053/jhin.1999.0613 · DOI
- Andersson, 1999, The biological cost of antibiotic resistance, Curr. Opin. Microbiol., 2, 489, 10.1016/S1369-5274(99)00005-3 · DOI · Paper page
- Kraemer, S.A., Ramachandran, A., and Perron, G.G. (2019). Antibiotic Pollution in the Environment: From Microbial Ecology to Public Policy. Microorganisms, 7. · DOI · Paper page
- Kramer, A., Schwebke, I., and Kampf, G. (2006). How long do nosocomial pathogens persist on inanimate surfaces? A systematic review. BMC Infect. Dis., 6. · DOI · Paper page
- Hota, 2004, Contamination, disinfection, and cross-colonization: Are hospital surfaces reservoirs for nosocomial infection?, Clin. Infect. Dis., 39, 1182, 10.1086/424667 · DOI · Paper page
- 2011, Antimicrobial strategies effective against infectious bacterial biofilms, Curr. Med. Chem., 18, 2129, 10.2174/092986711795656216 · DOI · Paper page
- Hanna, 2000, Control of nosocomial Clostridium difficile transmission in bone marrow transplant patients, Infect. Control Hosp. Epidemiol., 21, 226, 10.1086/501751 · DOI
- Dancer, 1999, Mopping up hospital infection, J. Hosp. Infect., 43, 85, 10.1053/jhin.1999.0616 · DOI · Paper page
- Weber, 2010, Role of hospital surfaces in the transmission of emerging health care-associated pathogens: Norovirus, Clostridium difficile, and Acinetobacter species, Am. J. Infect. Control, 38, S25, 10.1016/j.ajic.2010.04.196 · DOI · Paper page
- Saint, 2005, A reminder reduces urinary catheterization in hospitalized patients, Jt. Comm. J. Qual. Patient Saf., 31, 455
- Saint, 1999, Preventing Catheter-Related Bacteriuria: Should We? Can We? How?, Arch. Intern. Med., 159, 800, 10.1001/archinte.159.8.800 · DOI · Paper page
- Jeanes, 2005, Eradication of persistent environmental MRSA, J. Hosp. Infect., 61, 85, 10.1016/j.jhin.2005.01.001 · doi:10.1016/j.jhin.2005.01.001
- Blythe, 1998, Environmental contamination due to methicillin-resistant Staphylococcus aureus (MRSA), J. Hosp. Infect., 38, 67, 10.1016/S0195-6701(98)90176-1 · DOI
- French, 2004, Tackling contamination of the hospital environment by methicillin-resistant Staphylococcus aureus (MRSA): A comparison between conventional terminal cleaning and hydrogen peroxide vapour decontamination, J. Hosp. Infect., 57, 31, 10.1016/j.jhin.2004.03.006 · DOI · Paper page
- López, D., Vlamakis, H., and Kolter, R. (2010). Biofilms. Cold Spring Harb. Perspect. Biol., 2. · DOI · Paper page
- Fux, 2005, Survival strategies of infectious biofilms, Trends Microbiol., 13, 34, 10.1016/j.tim.2004.11.010 · DOI · Paper page
- Vickery, 2012, Presence of biofilm containing viable multiresistant organisms despite terminal cleaning on clinical surfaces in an intensive care unit, J. Hosp. Infect., 80, 52, 10.1016/j.jhin.2011.07.007 · DOI · Paper page
- Henry, 1996, Hydrogen peroxide 3% exposures, J. Toxicol. Clin. Toxicol., 34, 323, 10.3109/15563659609013797 · doi:10.3109/15563659609013797
- McDonnell, G.E. (2017). Antisepsis, Disinfection, and Sterilization: Types, Action, and Resistance, John Wiley & Sons. · doi:10.1128/9781555819682
- Block, S.S. (2001). Disinfection, Sterilization, and Preservation, Lippincott Williams & Wilkins.
- Caplin, J.L.S. (2013). Russell, Hugo & Ayliffe’s, John Wiley & Sons.
- Fichet, 2007, Prion inactivation using a new gaseous hydrogen peroxide sterilisation process, J. Hosp. Infect., 67, 278, 10.1016/j.jhin.2007.08.020 · DOI
- Manian, 2013, Implementation of hospital-wide enhanced terminal cleaning of targeted patient rooms and its impact on endemic Clostridium difficile infection rates, Am. J. Infect. Control, 41, 537, 10.1016/j.ajic.2012.06.014 · DOI
- Bates, 2005, Use of hydrogen peroxide vapour for environmental control during a Serratia outbreak in a neonatal intensive care unit, J. Hosp. Infect., 61, 364, 10.1016/j.jhin.2005.05.003 · DOI
- Otter, 2010, Hydrogen peroxide vapour decontamination of a critical care unit room used to treat a patient with Lassa fever, J. Hosp. Infect., 75, 335, 10.1016/j.jhin.2010.02.025 · doi:10.1016/j.jhin.2010.02.025
- Heckert, 1997, Efficacy of vaporized hydrogen peroxide against exotic animal viruses, Appl. Env. Microbiol., 63, 3916, 10.1128/aem.63.10.3916-3918.1997 · doi:10.1128/aem.63.10.3916-3918.1997
- Heck, 1990, Formaldehyde Toxicity—New Understanding, Crit. Rev. Toxicol., 20, 397, 10.3109/10408449009029329 · doi:10.3109/10408449009029329
- 2008, Ethylene oxide potential toxicity, Expert. Rev. Med. Devices, 5, 323, 10.1586/17434440.5.3.323 · doi:10.1586/17434440.5.3.323
- Klapes, 1990, Vapor-phase hydrogen peroxide as a surface decontaminant and sterilant, Appl. Env. Microbiol., 56, 503, 10.1128/aem.56.2.503-506.1990 · DOI · Paper page
- Wexler, P. (2014). Encyclopedia of Toxicology, Academic Press. [3rd ed.].
- Boyce, 2014, Compatibility of Hydrogen Peroxide Vapor Room Decontamination with Physiological Monitors, Infect. Control Hosp. Epidemiol., 35, 92, 10.1086/674388 · doi:10.1086/674388
- Sher, 2020, Comparison of Aerosolized Hydrogen Peroxide Fogging with a Conventional Disinfection Product for a Dental Surgery, J. Contemp. Dent. Pract., 21, 1308
- Gale, 2009, Effect of vapour phase hydrogen peroxide, as a decontaminant for civil aviation applications, on microstructure, tensile properties and corrosion resistance of 2024 and 7075 age hardenable aluminium alloys and 304 austenitic stainless steel, Mater. Sci. Technol., 25, 76, 10.1179/174328408X307256 · DOI
- Boyce, 2009, New approaches to decontamination of rooms after patients are discharged, Infect. Control Hosp. Epidemiol., 30, 515, 10.1086/598999 · DOI
- Otter, 2011, A call for clarity when discussing hydrogen peroxide vapour and aerosol systems, J. Hosp. Infect., 77, 83, 10.1016/j.jhin.2010.07.023 · doi:10.1016/j.jhin.2010.07.023
- Otter, 2010, Hydrogen Peroxide Vapor Is Not the Same as Aerosolized Hydrogen Peroxide, Infect. Control Hosp. Epidemiol., 31, 1201, 10.1086/657076 · doi:10.1086/657076
- Otter, 2009, Survival of nosocomial bacteria and spores on surfaces and inactivation by hydrogen peroxide vapor, J. Clin. Microbiol., 47, 205, 10.1128/JCM.02004-08 · DOI · Paper page
- Kahnert, 2005, Decontamination with vaporized hydrogen peroxide is effective against Mycobacterium tuberculosis, Lett. Appl. Microbiol., 40, 448, 10.1111/j.1472-765X.2005.01683.x · doi:10.1111/j.1472-765x.2005.01683.x
- Zhu, P.C. (2007). New Biocides Development: The Combined Approach of Chemistry and Microbiology, ACS Publications. · doi:10.1021/bk-2007-0967
- Finnegan, 2010, Mode of action of hydrogen peroxide and other oxidizing agents: Differences between liquid and gas forms, J. Antimicrob. Chemother., 65, 2108, 10.1093/jac/dkq308 · DOI · Paper page
- Pottage, 2010, Evaluation of hydrogen peroxide gaseous disinfection systems to decontaminate viruses, J. Hosp. Infect., 74, 55, 10.1016/j.jhin.2009.08.020 · DOI
- Wang, 2021, N95 respirator decontamination: A study in reusability, Mater. Today Adv., 11, 100148, 10.1016/j.mtadv.2021.100148 · DOI
- Spaulding, 1972, Chemical disinfection and antisepsis in the hospital, J. Hosp. Res., 9, 5
- Barbut, 2012, Activity in vitro of hydrogen peroxide vapour against Clostridium difficile spores, J. Hosp. Infect., 80, 85, 10.1016/j.jhin.2011.10.005 · doi:10.1016/j.jhin.2011.10.005
- Bentley, 2012, Hydrogen peroxide vapour decontamination of surfaces artificially contaminated with norovirus surrogate feline calicivirus, J. Hosp. Infect., 80, 116, 10.1016/j.jhin.2011.10.010 · doi:10.1016/j.jhin.2011.10.010
- Berrie, 2011, Hydrogen peroxide vapour (HPV) inactivation of adenovirus, Lett. Appl. Microbiol., 52, 555, 10.1111/j.1472-765X.2011.03033.x · doi:10.1111/j.1472-765x.2011.03033.x
- Hall, 2007, Use of hydrogen peroxide vapor for deactivation of Mycobacterium tuberculosis in a biological safety cabinet and a room, J. Clin. Microbiol., 45, 810, 10.1128/JCM.01797-06 · DOI
- Cooper, 2011, Impact of environmental decontamination using hydrogen peroxide vapour on the incidence of Clostridium difficile infection in one hospital Trust, J. Hosp. Infect., 78, 238, 10.1016/j.jhin.2010.12.013 · doi:10.1016/j.jhin.2010.12.013
- Dryden, 2008, Hydrogen peroxide vapour decontamination in the control of a polyclonal meticillin-resistant Staphylococcus aureus outbreak on a surgical ward, J. Hosp. Infect., 68, 190, 10.1016/j.jhin.2007.11.003 · doi:10.1016/j.jhin.2007.11.003
- Bailey, C., Makison-Booth, C., Farrant, J., Beswick, A., Chewins, J., Eimstad, M., Heyerdahl, F., and Crook, B. (2021). Validation of the Decontamination of a Specialist Transport System for Patients with High Consequence Infectious Diseases. Microorganisms, 9. · doi:10.3390/microorganisms9122575
- Khandelwal, A., Lapolla, B., Bair, T., Grinstead, F., Hislop, M., Greene, C., and Bigham, M.T. (2022). Enhanced disinfection with hybrid hydrogen peroxide fogging in a critical care setting. BMC Infect. Dis., 22. · DOI
- Marra, 2018, No-Touch Disinfection Methods to Decrease Multidrug-Resistant Organism Infections: A Systematic Review and Meta-analysis, Infect. Control Hosp. Epidemiol., 39, 20, 10.1017/ice.2017.226 · DOI · Paper page
- Boyce, 2008, Impact of hydrogen peroxide vapor room decontamination on Clostridium difficile environmental contamination and transmission in a healthcare setting, Infect. Control Hosp. Epidemiol., 29, 723, 10.1086/589906 · DOI · Paper page
- Passaretti, 2012, An Evaluation of Environmental Decontamination With Hydrogen Peroxide Vapor for Reducing the Risk of Patient Acquisition of Multidrug-Resistant Organisms, Clin. Infect. Dis., 56, 27, 10.1093/cid/cis839 · DOI · Paper page
- Abner, 2020, Antimicrobial-resistant pathogens associated with adult healthcare-associated infections: Summary of data reported to the National Healthcare Safety Network, 2015–2017, Infect. Control Hosp. Epidemiol., 41, 1
- Back, 2014, Effect of hydrogen peroxide vapor treatment for inactivating Salmonella Typhimurium, Escherichia coli O157:H7 and Listeria monocytogenes on organic fresh lettuce, Food Control, 44, 78, 10.1016/j.foodcont.2014.03.046 · doi:10.1016/j.foodcont.2014.03.046
- Benga, 2017, Survival of bacteria of laboratory animal origin on cage bedding and inactivation by hydrogen peroxide vapour, Lab. Anim., 51, 412, 10.1177/0023677216675386 · doi:10.1177/0023677216675386
- Lemmen, 2015, Evaluation of hydrogen peroxide vapor for the inactivation of nosocomial pathogens on porous and nonporous surfaces, Am. J. Infect. Control, 43, 82, 10.1016/j.ajic.2014.10.007 · doi:10.1016/j.ajic.2014.10.007
- Podschun, 1998, Klebsiella spp. as Nosocomial Pathogens: Epidemiology, Taxonomy, Typing Methods, and Pathogenicity Factors, Clin. Microbiol. Rev., 11, 589, 10.1128/CMR.11.4.589 · DOI · Paper page
- Ali, 2016, Efficacy of two hydrogen peroxide vapour aerial decontamination systems for enhanced disinfection of meticillin-resistant Staphylococcus aureus, Klebsiella pneumoniae and Clostridium difficile in single isolation rooms, J. Hosp. Infect., 93, 70, 10.1016/j.jhin.2016.01.016 · doi:10.1016/j.jhin.2016.01.016
- Singh, 2016, Klebsiella oxytoca: An emerging pathogen?, Med. J. Armed Forces India., 72, S59, 10.1016/j.mjafi.2016.05.002 · DOI
- Watson, 2018, Modelling vaporised hydrogen peroxide efficacy against mono-species biofilms, Sci. Rep., 8, 12257, 10.1038/s41598-018-30706-0 · DOI · Paper page
- Otter, 2010, Hydrogen peroxide vapor decontamination of an intensive care unit to remove environmental reservoirs of multidrug-resistant gram-negative rods during an outbreak, Am. J. Infect. Control, 38, 754, 10.1016/j.ajic.2010.03.010 · DOI
- McDonnell, 2002, Vapor phase hydrogen peroxide decontamination of food contact surfaces, Dairy. Food Environ. Sanit., 22, 868
- Sexton, 2011, Reduction in the microbial load on high-touch surfaces in hospital rooms by treatment with a portable saturated steam vapor disinfection system, Am. J. Infect. Control, 39, 655, 10.1016/j.ajic.2010.11.009 · DOI
- Otter, 2007, Assessing the biological efficacy and rate of recontamination following hydrogen peroxide vapour decontamination, J. Hosp. Infect., 67, 182, 10.1016/j.jhin.2007.07.019 · doi:10.1016/j.jhin.2007.07.019
- Pottage, 2012, Meticillin-resistant Staphylococcus aureus is more resistant to vaporized hydrogen peroxide than commercial Geobacillus stearothermophilus biological indicators, J. Hosp. Infect., 80, 41, 10.1016/j.jhin.2011.11.001 · DOI
- Fu, 2012, Efficacy, efficiency and safety aspects of hydrogen peroxide vapour and aerosolized hydrogen peroxide room disinfection systems, J. Hosp. Infect., 80, 199, 10.1016/j.jhin.2011.11.019 · doi:10.1016/j.jhin.2011.11.019
- Otter, 2012, Impact of the suspending medium on susceptibility of meticillin-resistant Staphylococcus aureus to hydrogen peroxide vapour decontamination, J. Hosp. Infect., 82, 213, 10.1016/j.jhin.2012.08.006 · doi:10.1016/j.jhin.2012.08.006
- Fisher, 2016, A successful vancomycin-resistant enterococci reduction bundle at a Singapore hospital, Infect. Control Hosp. Epidemiol., 37, 107, 10.1017/ice.2015.251 · DOI
- Annavajhala, M.K., Gomez-Simmonds, A., and Uhlemann, A.-C. (2019). Multidrug-Resistant Enterobacter cloacae Complex Emerging as a Global, Diversifying Threat. Front. Microbiol., 10. · DOI · Paper page
- Madigan, M.T., Martinko, J.M., and Parker, J. (1997). Brock Biology of Microorganisms, Prentice Hall Upper.
- Rudnick, 2009, Inactivating influenza viruses on surfaces using hydrogen peroxide or triethylene glycol at low vapor concentrations, Am. J. Infect. Control, 37, 813, 10.1016/j.ajic.2009.06.007 · doi:10.1016/j.ajic.2009.06.007
- Goyal, 2014, Evaluating the virucidal efficacy of hydrogen peroxide vapour, J. Hosp. Infect., 86, 255, 10.1016/j.jhin.2014.02.003 · DOI · Paper page
- Linley, 2012, Use of hydrogen peroxide as a biocide: New consideration of its mechanisms of biocidal action, J. Antimicrob. Chemother., 67, 1589, 10.1093/jac/dks129 · DOI · Paper page
- Repine, 1981, Hydrogen peroxide kills Staphylococcus aureus by reacting with staphylococcal iron to form hydroxyl radical, J. Biol. Chem., 256, 7094, 10.1016/S0021-9258(19)68927-1 · DOI · Paper page
- Imlay, 1986, Bimodal pattern of killing of DNA-repair-defective or anoxically grown Escherichia coli by hydrogen peroxide, J. Bacteriol., 166, 519, 10.1128/jb.166.2.519-527.1986 · DOI · Paper page
- Schwartz, 1983, Catalase and superoxide dismutase in Escherichia coli, J. Biol. Chem., 258, 6277, 10.1016/S0021-9258(18)32404-9 · doi:10.1016/s0021-9258(18)32404-9
- Brandi, 1987, The effect of temperature or anoxia on Escherichia coli killing induced by hydrogen peroxide, Mutat. Res. Lett., 190, 237, 10.1016/0165-7992(87)90002-9 · doi:10.1016/0165-7992(87)90002-9
- Linley, E. (2012). Understanding the Iinteractions of Hydrogen Peroxide with Macromolecules and Microbial Components. [Ph.D. Dissertation, Cardiff University].
- McDonnell, 2007, Peroxygens and Other Forms of Oxygen: Their Use for Effective Cleaning, Disinfection, and Sterilization, New Biocides Development, Volume 967, 292, 10.1021/bk-2007-0967.ch013 · doi:10.1021/bk-2007-0967.ch013
- Fauci, 2020, COVID-19—Navigating the Uncharted, New Engl. J. Med., 382, 1268, 10.1056/NEJMe2002387 · DOI · Paper page
- Wigginton, 2020, Validation of N95 Filtering Facepiece Respirator Decontamination Methods Available at a Large University Hospital, Open Forum Infect. Dis., 8, ofaa610, 10.1093/ofid/ofaa610 · DOI
- Oral, E., Wannomae, K.K., Connolly, R.L., Gardecki, J.A., Leung, H.M., Muratoglu, O.K., Durkin, J., Jones, R., Collins, C., and Gjore, J. (2020). Vaporized H2O2 decontamination against surrogate viruses for the reuse of N95 respirators in the COVID-19 emergency. medRxiv. · DOI
- Kumar, A., Kasloff, S.B., Leung, A., Cutts, T., Strong, J.E., Hills, K., Vazquez-Grande, G., Rush, B., Lother, S., and Zarychanski, R. (2020). N95 mask decontamination using standard hospital sterilization technologies. medRxiv. · DOI
- Kenney, 2021, Hydrogen peroxide vapor decontamination of N95 respirators for reuse, Infect. Control Hosp. Epidemiol., 43, 45, 10.1017/ice.2021.48 · DOI
- Schwartz, 2020, Decontamination and Reuse of N95 Respirators with Hydrogen Peroxide Vapor to Address Worldwide Personal Protective Equipment Shortages During the SARS-CoV-2 (COVID-19) Pandemic, Appl. Biosaf., 25, 67, 10.1177/1535676020919932 · DOI
- Perkins, 2020, COVID-19 global pandemic planning: Decontamination and reuse processes for N95 respirators, Exp. Biol. Med., 245, 933, 10.1177/1535370220925768 · DOI
- Grossman, 2020, Institution of a Novel Process for N95 Respirator Disinfection with Vaporized Hydrogen Peroxide in the Setting of the COVID-19 Pandemic at a Large Academic Medical Center, J. Am. Coll. Surg., 231, 275, 10.1016/j.jamcollsurg.2020.04.029 · DOI
Cited by
Biofilm Resilience: Molecular Mechanisms Driving Antibiotic Resistance in Clinical Contexts
Almatroudi, A. (2025) · Biology · doi:10.3390/biology14020165 · Cited by 303
Metadata
- Authors
- Ayub, A., Cheong, Y. K., Castro, J. C., Cumberlege, O., & Chrysanthou, A.
- Venue
- Bioengineering
- Publisher
- MDPI AG
- Published
- 2024-02-22
- Volume
- 11
- Issue
- 3
- Pages
- 205
- ISSN
- 2306-5354
- Cited by
- 38
- References
- 5
- Language
- en
- Funders
- Ecolab (formerly known as Bioquell, UK)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.