Recent Optical Coherence Tomography (OCT) Innovations for Increased Accessibility and Remote Surveillance

Devine, Brigid C., Dogan, Alan B., Sobol, Warren M. · 2025 · Bioengineering

Abstract

Optical Coherence Tomography (OCT) has revolutionized the diagnosis and management of retinal diseases, offering high-resolution, cross-sectional imaging that aids in early detection and continuous monitoring. However, traditional OCT devices are limited to clinical settings and require a technician to operate, which poses accessibility challenges such as a lack of appointment availability, patient and family burden of frequent transportation, and heightened healthcare costs, especially when treatable pathology is undetected. With the increasing global burden of retinal conditions such as age-related macular degeneration (AMD) and diabetic retinopathy, there is a critical need for improved accessibility in the detection of retinal diseases. Advances in biomedical engineering have led to innovations such as portable models, community-based systems, and artificial intelligence-enabled image analysis. The SightSync OCT is a community-based, technician-free device designed to enhance accessibility while ensuring secure data transfer and high-quality imaging (6 × 6 mm resolution, 80,000 A-scans/s). With its compact design and potential for remote interpretation, SightSync widens the possibility for community-based screening for vision-threatening retinal diseases. By integrating innovations in OCT imaging, the future of monitoring for retinal disease can be transformed to reduce barriers to care and improve patient outcomes. This article discusses the evolution of OCT technology, its role in the diagnosis and management of retinal diseases, and how novel engineering solutions like SightSync OCT are transforming accessibility in retinal imaging.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/bioengineering12050441

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 83

  1. Zhou, 2023, Visual impairment and blindness caused by retinal diseases: A nationwide register-based study, J. Glob. Health, 13, 04126, 10.7189/jogh.13.04126 · DOI
  2. Nam, K.T., Yun, C., Seo, M., Ahn, S., and Oh, J. (2024). Comparison of retinal thickness measurements among four different optical coherence tomography devices. Sci. Rep., 14. · doi:10.1038/s41598-024-54109-6
  3. Kropp, 2023, Diabetic retinopathy as the leading cause of blindness and early predictor of cascading complications—Risks and mitigation, EPMA J., 14, 21, 10.1007/s13167-023-00314-8 · DOI · Paper page
  4. Furtado, 2024, Global estimates on the number of people blind or visually impaired by age-related macular degeneration: A meta-analysis from 2000 to 2020, Eye, 38, 2070, 10.1038/s41433-024-03050-z · DOI
  5. Saeedi, 2019, Global and regional diabetes prevalence estimates for 2019 and projections for 2030 and 2045: Results from the International Diabetes Federation Diabetes Atlas, 9th ed, Diabetes Res. Clin. Pract., 157, 107843, 10.1016/j.diabres.2019.107843 · DOI · Paper page
  6. Fleckenstein, 2024, Age-Related Macular Degeneration: A Review, JAMA, 331, 147, 10.1001/jama.2023.26074 · DOI · Paper page
  7. Zhang, S., Ren, J., Chai, R., Yuan, S., and Hao, Y. (2024). Global burden of low vision and blindness due to age-related macular degeneration from 1990 to 2021 and projections for 2050. BMC Public Health, 24. · DOI
  8. Sikorski, 2013, The diagnostic function of OCT in diabetic maculopathy, Mediat. Inflamm., 2013, 434560, 10.1155/2013/434560 · DOI
  9. Elsharkawy, M., Elrazzaz, M., Ghazal, M., Alhalabi, M., Soliman, A., Mahmoud, A., El-Daydamony, E., Atwan, A., Thanos, A., and Sandhu, H.S. (2021). Role of optical coherence tomography imaging in predicting progression of age-related macular disease: A survey. Diagnostics, 11. · DOI
  10. Geevarghese, 2021, Optical Coherence Tomography and Glaucoma, Annu. Rev. Vis. Sci., 7, 693, 10.1146/annurev-vision-100419-111350 · DOI
  11. Huang, 1991, Optical Coherence Tomography HHS Public Access, Science, 254, 1178, 10.1126/science.1957169 · DOI · Paper page
  12. Zeppieri, M., Marsili, S., Enaholo, E.S., Shuaibu, A.O., Uwagboe, N., Salati, C., Spadea, L., and Musa, M. (2023). Optical Coherence Tomography (OCT): A Brief Look at the Uses and Technological Evolution of Ophthalmology. Medicina, 59. · DOI
  13. Adhi, 2013, Optical coherence tomography-current and future applications, Curr. Opin. Ophthalmol., 24, 213, 10.1097/ICU.0b013e32835f8bf8 · DOI · Paper page
  14. Rein, 2022, Prevalence of Age-Related Macular Degeneration in the US in 2019, JAMA Ophthalmol., 140, 1202, 10.1001/jamaophthalmol.2022.4401 · DOI · Paper page
  15. Rufai, 2022, Handheld optical coherence tomography removes barriers to imaging the eyes of young children, Eye, 36, 907, 10.1038/s41433-021-01884-5 · doi:10.1038/s41433-021-01884-5
  16. Chopra, 2021, Optical coherence tomography in the 2020s—Outside the eye clinic, Eye, 35, 236, 10.1038/s41433-020-01263-6 · DOI
  17. Kumar, 2024, A Comprehensive Review of Ocular Manifestations in Systemic Diseases, Cureus, 16, e65693
  18. Burns, 2021, Imaging the Retinal Vasculature, Annu. Rev. Vis. Sci., 7, 129, 10.1146/annurev-vision-093019-113719 · DOI
  19. Panwar, 2016, Fundus photography in the 21st century—A review of recent technological advances and their implications for worldwide healthcare, Telemed. e-Health, 22, 198, 10.1089/tmj.2015.0068 · DOI · Paper page
  20. Kornblau, 2019, Adverse reactions to fluorescein angiography: A comprehensive review of the literature, Surv Ophthalmol., 64, 679, 10.1016/j.survophthal.2019.02.004 · DOI
  21. Silverman, 2023, Principles of ophthalmic ultrasound, Expert Rev. Ophthalmol., 18, 379, 10.1080/17469899.2023.2277781 · doi:10.1080/17469899.2023.2277781
  22. Bodenbender, 2023, Impact of A-Scan Rate on Image Quality and Acquisition Time in OCT, Curr. Eye Res., 48, 973, 10.1080/02713683.2023.2232957 · doi:10.1080/02713683.2023.2232957
  23. Aumann, S., Donner, S., and Fischer, J. (2019). High Resolution Imaging in Microscopy and Ophthalmology, Springer.
  24. Bosche, 2019, Spectralis OCT1 versus OCT2: Time efficiency and image quality of retinal nerve fiber layer thickness and bruch’s membrane opening analysis for glaucoma patients, J. Curr. Glaucoma Pract., 13, 16, 10.5005/jp-journals-10078-1244 · doi:10.5005/jp-journals-10078-1244
  25. Barteselli, 2013, Accuracy of the heidelberg spectralis in the alignment between near-infrared image and tomographic scan in a model eye: A multicenter study, Am. J. Ophthalmol., 156, 588, 10.1016/j.ajo.2013.04.030 · DOI
  26. Brennen, 2009, Comparison of StratusOCT and Cirrus HD-OCT Imaging in Macular Diseases, Ophthalmic Surg. Lasers Imaging Retin., 40, 25, 10.3928/15428877-20090101-01 · doi:10.3928/15428877-20090101-01
  27. Munk, M.R., Giannakaki-Zimmermann, H., Berger, L., Huf, W., Ebneter, A., Wolf, S., and Zinkernagel, M.S. (2017). OCT-angiography: A qualitative and quantitative comparison. PLoS ONE, 12. · doi:10.1371/journal.pone.0177059
  28. Romano, 2015, A review of optical coherence tomography angiography (OCTA), Int. J. Retin. Vitr., 1, 5, 10.1186/s40942-015-0005-8 · DOI · Paper page
  29. Chhablani, 2014, Artifacts in optical coherence tomography, Saudi J. Ophthalmol., 28, 81, 10.1016/j.sjopt.2014.02.010 · doi:10.1016/j.sjopt.2014.02.010
  30. Chua, 2024, Optical coherence tomography angiography of the retina and choroid in systemic diseases, Prog. Retin. Eye Res., 103, 101292, 10.1016/j.preteyeres.2024.101292 · DOI
  31. Islam, M.M., Poly, T.N., Walther, B.A., Yang, H.C., and Li, Y.C. (2020). Artificial intelligence in ophthalmology: A meta-analysis of deep learning models for retinal vessels segmentation. J. Clin. Med., 9. · DOI
  32. Karn, P.K., and Abdulla, W.H. (2024). Precision Segmentation of Subretinal Fluids in OCT Using Multiscale Attention-Based U-Net Architecture. Bioengineering, 11. · DOI
  33. Eppenberger, 2024, Retinal thickness predicts the risk of cognitive decline over five years, Alzheimer’s Res. Ther., 16, 273, 10.1186/s13195-024-01627-0 · DOI
  34. Arana, 2021, Retinal Thickness Predicts the Risk of Cognitive Decline in Parkinson Disease, Ann. Neurol., 89, 165, 10.1002/ana.25944 · DOI
  35. Choudhary, A., Ahlawat, S., Urooj, S., Pathak, N., Lay-Ekuakille, A., and Sharma, N. (2023). A Deep Learning-Based Framework for Retinal Disease Classification. Healthcare, 11. · DOI
  36. Yojana, 2023, OCT layer segmentation using U-NET semantic segmentation and RESNET34 encoder-decoder, Meas. Sens., 29, 100817, 10.1016/j.measen.2023.100817 · DOI
  37. Lim, 2023, Artificial Intelligence Detection of Diabetic Retinopathy: Subgroup Comparison of the EyeArt System with Ophthalmologists’ Dilated Examinations, Ophthalmol. Sci., 3, 100228, 10.1016/j.xops.2022.100228 · DOI · Paper page
  38. Rodríguez-Miguel, A., Arruabarrena, C., Allendes, G., Olivera, M., Zarranz-Ventura, J., and Teus, M.A. (2024). Hybrid deep learning models for the screening of Diabetic Macular Edema in optical coherence tomography volumes. Sci. Rep., 14. · DOI
  39. Borrelli, 2024, Deep-learning based automated quantification of critical optical coherence tomography features in neovascular age-related macular degeneration, Eye, 38, 537, 10.1038/s41433-023-02720-8 · DOI
  40. Flaxel, 2020, Age-Related Macular Degeneration Preferred Practice Pattern®, Ophthalmology, 127, P1, 10.1016/j.ophtha.2019.09.024 · DOI · Paper page
  41. Han, 2024, Anti-VEGF treatment outcome prediction based on optical coherence tomography images in neovascular age-related macular degeneration using a deep neural network, Sci Rep., 14, 28253, 10.1038/s41598-024-79034-6 · DOI
  42. Berkowitz, 2024, Ophthalmology Workforce Projections in the United States, 2020 to 2035, Ophthalmology, 131, 133, 10.1016/j.ophtha.2023.09.018 · DOI
  43. Thompson, 2015, Barriers to follow-up and strategies to improve adherence to appointments for care of chronic eye diseases, Invest. Ophthalmol. Vis. Sci., 56, 4324, 10.1167/iovs.15-16444 · DOI
  44. Burton, 2021, The Lancet Global Health Commission on Global Eye Health: Vision Beyond 2020, Lancet Glob. Health, 9, e489, 10.1016/S2214-109X(20)30488-5 · DOI · Paper page
  45. Viehland, C., Chen, X., Tran-Viet, D., Jackson-Atogi, M., Ortiz, P., Waterman, G., Vajzovic, L., Toth, C.A., and Izatt, J.A. (2019). Ergonomic handheld OCT angiography probe optimized for pediatric and supine imaging. Biomed. Opt. Express, 10. · doi:10.1364/boe.10.002623
  46. Duan, Z., Huang, K., Luo, Z., Ma, K., Wang, G., Hu, X., Zhang, J., Luo, X., Huang, Y., and Liu, G. (2022). Portable boom-type ultrahigh-resolution OCT with an integrated imaging probe for supine position retinal imaging. Biomed. Opt. Express, 13. · doi:10.1364/boe.456435
  47. Zhang, J., Nguyen, T., Potsaid, B., Jayaraman, V., Burgner, C., Chen, S., Li, J., Liang, K., Cable, A., and Traverso, G. (2021). Multi-MHz MEMS-VCSEL swept-source optical coherence tomography for endoscopic structural and angiographic imaging with miniaturized brushless motor probes. Biomed. Opt. Express, 12. · doi:10.1364/boe.420394
  48. Gorecki, C., Lullin, J., Perrin, S., Bargiel, S., Albero, J., Gaiffe, O., Rutkowski, J., Cote, J.M., Krauter, J., and Osten, W. (2019). Micromachined phase-shifted array-type Mirau interferometer for swept-source OCT imaging: Design, microfabrication and experimental validation. Biomed. Opt. Express, 10. · doi:10.1364/boe.10.001111
  49. Kim, S., Lee, C., Kim, J.Y., Kim, J., Lim, G., and Kim, C. (2016). Two-axis polydimethylsiloxane-based electromagnetic microelectromechanical system scanning mirror for optical coherence tomography. J. Biomed. Opt., 21. · doi:10.1117/1.jbo.21.10.106001
  50. Price, H.B., Song, G., Wang, W., O’Kane, E., Lu, K., Jelly, E., Miller, D.A., and Wax, A. (2025). Development of next generation low-cost OCT towards improved point-of-care retinal imaging. Biomed. Opt. Express, 16, Available online: https://opg.optica.org/abstract.cfm?URI=boe-16-2-748. · doi:10.1364/boe.551625
  51. Malone, J.D., Hussain, I., and Bowden, A.K. (2023). SmartOCT: Smartphone-integrated optical coherence tomography. Biomed. Opt. Express, 14. · doi:10.1364/boe.492439
  52. Dolar-Szczasny, J., Drab, A., and Rejdak, R. (2024). Home-monitoring/remote optical coherence tomography in teleophthalmology in patients with eye disorders—A systematic review. Front. Med., 11. · DOI
  53. Sudkamp, 2022, Self-Examination Low-Cost Full-Field Optical Coherence Tomography (SELFF-OCT) for neovascular age-related macular degeneration: A cross-sectional diagnostic accuracy study, BMJ Open, 12, e055082, 10.1136/bmjopen-2021-055082 · doi:10.1136/bmjopen-2021-055082
  54. Moltmann, 2020, Self-examination low-cost full-field OCT (SELFF-OCT) for patients with various macular diseases, Graefe’s Arch. Clin. Exp. Ophthalmol., 259, 1503
  55. Giardini, M.E., and Livingstone, I.A.T. (2020). Extending the Reach and Task-Shifting Ophthalmology Diagnostics Through Remote Visualisation. Advances in Experimental Medicine and Biology, Springer. · DOI
  56. Horton, 2020, Practice Guidelines for Ocular Telehealth-Diabetic Retinopathy, Third Edition, Telemed. e-Health, 26, 495, 10.1089/tmj.2020.0006 · DOI
  57. Kim, S., Crose, M., Eldridge, W.J., Cox, B., Brown, W.J., and Wax, A. (2018). Design and implementation of a low-cost, portable OCT system. Biomed. Opt. Express, 9. · DOI
  58. Song, 2019, First clinical application of low-cost OCT, Transl. Vis. Sci. Technol., 8, 61, 10.1167/tvst.8.3.61 · DOI
  59. Hu, 2020, Large depth-of-field three-dimensional shape measurement with the focal sweep technique, Opt. Express, 28, 31197, 10.1364/OE.404260 · doi:10.1364/oe.404260
  60. Gaitan, N.C. (2021). A long-distance communication architecture for medical devices based on lorawan protocol. Electronics, 10. · doi:10.3390/electronics10080940
  61. Kiourtis, A., Mavrogiorgou, A., and Kyriazis, D. (2022). Health information exchange through a Device-to-Device protocol supporting lossless encoding and decoding. J. Biomed. Inform., 134. · doi:10.1016/j.jbi.2022.104199
  62. Bracciale, L., Loreti, P., and Bianchi, G. (2023). Cybersecurity vulnerability analysis of medical devices purchased by national health services. Sci. Rep., 13. · doi:10.1038/s41598-023-45927-1
  63. Salunkhe, 2024, Advanced Encryption Techniques in Healthcare IoT: Securing Patient Data in Connected Medical Devices, Mod. Dyn. Math. Progress., 1, 224
  64. Alkhafajee, A.R., Ali Al-Muqarm, A.M., Alwan, A.H., and Mohammed, Z.R. (2021). Security and Performance Analysis of MQTT Protocol with TLS in IoT Networks. 4th International Iraqi Conference on Engineering Technology and Their Applications, IICETA 2021, Institute of Electrical and Electronics Engineers Inc. · doi:10.1109/iiceta51758.2021.9717495
  65. Baumann, B., Merkle, C.W., Leitgeb, R.A., Augustin, M., Wartak, A., Pircher, M., and Hitzenberger, C.K. (2019). Signal averaging improves signal-to-noise in OCT images: But which approach works best, and when?. Biomed. Opt. Express, 10. · DOI
  66. Luo, 2017, The Edge Detectors Suitable for Retinal OCT Image Segmentation, J. Healthc. Eng., 2017, 3978410, 10.1155/2017/3978410 · DOI
  67. Leandro, I., Lorenzo, B., Aleksandar, M., Dario, M., Rosa, G., Agostino, A., and Daniele, T. (2023). OCT-based deep-learning models for the identification of retinal key signs. Sci. Rep., 13. · DOI
  68. Karthik, K., and Mahadevappa, M. (2023). Convolution neural networks for optical coherence tomography (OCT) image classification. Biomed. Signal Process. Control., 79. · DOI
  69. Huang, 2023, SNR-Net OCT: Brighten and denoise low-light optical coherence tomography images via deep learning, Opt. Express, 31, 20696, 10.1364/OE.491391 · DOI
  70. Ledsam, 2018, Clinically applicable deep learning for diagnosis and referral in retinal disease, Nat. Med., 24, 1342, 10.1038/s41591-018-0107-6 · DOI · Paper page
  71. Yim, 2020, Predicting conversion to wet age-related macular degeneration using deep learning, Nat. Med., 26, 892, 10.1038/s41591-020-0867-7 · DOI · Paper page
  72. Schlegl, 2019, f-AnoGAN: Fast unsupervised anomaly detection with generative adversarial networks, Med. Image Anal., 54, 30, 10.1016/j.media.2019.01.010 · DOI · Paper page
  73. Ran, 2019, Detection of glaucomatous optic neuropathy with spectral-domain optical coherence tomography: A retrospective training and validation deep-learning analysis, Lancet Digit. Health, 1, e172, 10.1016/S2589-7500(19)30085-8 · DOI
  74. Leingang, O., Riedl, S., Mai, J., Reiter, G.S., Faustmann, G., Fuchs, P., Scholl, H.P.N., Sivaprasad, S., Rueckert, D., and Lotery, A. (2023). Automated deep learning-based AMD detection and staging in real-world OCT datasets (PINNACLE study report 5). Sci. Rep., 13. · DOI
  75. Holm, 2023, Optical coherence tomography for presurgical delineation of basal cell carcinomas on the face—A comparison with histopathology, J. Cutan. Pathol., 50, 441, 10.1111/cup.14412 · DOI
  76. Verma, 2024, Developing a 10-Layer Retinal Segmentation for MacTel Using Semi-Supervised Learning, Transl. Vis. Sci. Technol., 13, 2, 10.1167/tvst.13.11.2 · DOI
  77. Kugelman, J., Alonso-Caneiro, D., Read, S.A., Vincent, S.J., and Collins, M.J. (2018). Automatic segmentation of OCT retinal boundaries using recurrent neural networks and graph search. Biomed. Opt. Express, 9. · DOI
  78. Mukherjee, 2025, Validation of Deep Learning–Based Automatic Retinal Layer Segmentation Algorithms for Age-Related Macular Degeneration with 2 Spectral-Domain OCT Devices, Ophthalmol. Sci., 5, 100670, 10.1016/j.xops.2024.100670 · DOI
  79. Bai, Y., Li, J., Shi, L., Jiang, Q., Yan, B., and Wang, Z. (2023). DME-DeepLabV3+: A lightweight model for diabetic macular edema extraction based on DeepLabV3+ architecture. Front. Med., 10. · DOI
  80. Wilson, 2021, Validation and Clinical Applicability of Whole-Volume Automated Segmentation of Optical Coherence Tomography in Retinal Disease Using Deep Learning, JAMA Ophthalmol., 139, 964, 10.1001/jamaophthalmol.2021.2273 · DOI
  81. Wu, 2023, Training Deep Learning Models to Work on Multiple Devices by Cross-Domain Learning with No Additional Annotations, Ophthalmology, 130, 213, 10.1016/j.ophtha.2022.09.014 · DOI
  82. Roy, A.G., Conjeti, S., Karri, S.P.K., Sheet, D., Katouzian, A., Wachinger, C., and Navab, N. (2017). ReLayNet: Retinal layer and fluid segmentation of macular optical coherence tomography using fully convolutional networks. Biomed. Opt. Express, 8. · DOI · Paper page
  83. Yordi, S., Cakir, Y., Kalra, G., Cetin, H., Hu, M., Abraham, J., Reese, J., Srivastava, S.K., and Ehlers, J.P. (2024). Ellipsoid Zone Integrity and Visual Function in Dry Age-Related Macular Degeneration. J. Pers. Med., 14. · doi:10.3390/jpm14050543

Cited by

See all 16

Metadata

Authors
Devine, B. C., Dogan, A. B., & Sobol, W. M.
Venue
Bioengineering
Publisher
MDPI AG
Published
2025-04-23
Volume
12
Issue
5
Pages
441
ISSN
2306-5354
Cited by
16
References
10
Language
en
Funders
  • Veterans Health Association
  • Louis Stokes Cleveland Department of Veterans Affairs Medical Center

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.