Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Open accessThe DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
Microfluidic lab-on-a-chip cell culture techniques have been gaining popularity by offering the possibility of reducing the amount of samples and reagents and greater control over cellular microenvironment. Polydimethylsiloxane (PDMS) is the commonly used polymer for microfluidic cell culture devices because of the cheap and easy fabrication techniques, non-toxicity, biocompatibility, high gas permeability, and optical transparency. However, the intrinsic hydrophobic nature of PDMS makes cell seeding challenging when applied on PDMS surface. The hydrophobicity of the PDMS surface also allows the non-specific absorption/adsorption of small molecules and biomolecules that might affect the cellular behaviour and functions. Hydrophilic modification of PDMS surface is indispensable for successful cell seeding. This review collates different techniques with their advantages and disadvantages that have been used to improve PDMS hydrophilicity to facilitate endothelial cells seeding in PDMS devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell-laden microengineered gelatin methacrylate hydrogels
Nichol, J. W., Koshy, S. T., Bae, H., Hwang, C. M., Yamanlar, S., & Khademhosseini, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.064 · Cited by 2,377 · cited 1×
“HUVECs shows strong adhesion to PDMS coated with gelatin under flow [45,46].”
BackgroundSoft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,334 · cited 1×
“Soft lithography involves a group of patterning methods, such as imprinting, casting, and embossing with the elastomeric master mould or stamp [26].”
MethodMicrofluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717 · cited 3×
“PDMS exhibits a relatively low glass transition temperature and liquid at room temperature that makes it suitable to fabricate a replica from the master mould [13,17].”
BackgroundMethodThe extracellular matrix in development and morphogenesis: A dynamic view
Rozario, T., & DeSimone, D. W. (2010) · Developmental Biology · doi:10.1016/j.ydbio.2009.10.026 · Cited by 1,451 · cited 1×
“Full recovery is obtained after 24 h air exposure, which limits the suitability for cell seeding [32,57,73,74].”
BackgroundCharacterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems
Mata, A., Fleischman, A. J., & Roy, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6070-2 · Cited by 1,318
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190 · cited 1×
“Moreover, hydrophobicity might lead to absorption/adsorption of non-specific small molecules and biomolecules present in the cell media or secreted from the cells on the PDMS surface [21].”
BackgroundReal-time deformability cytometry: on-the-fly cell mechanical phenotyping
Otto, O., Rosendahl, P., Mietke, A., Golfier, S., Herold, C., Klaue, D., Girardo, S., Pagliara, S., Ekpenyong, A., Jacobi, A., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3281 · Cited by 736 · cited 1×
“Bright field imaging technique can precisely track, and image of small molecules or single cell in microfluidic device even at high frame rates [16].”
BackgroundMicrofluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622 · cited 2×
“Mainly, this ratio provides the optimum mechanical properties and biocompatibility for cell culture [15,22].”
BackgroundBodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600 · cited 1×
“Among all, oxygen plasma treatment shows the most rapid increase of the hydrophilicity of PDMS surface by removing hydrocarbon groups and introducing polar silanol (SiOH) groups (Figure 2) via oxidization [18,72].”
BackgroundMussel Adhesive Protein Mimetic Polymers for the Preparation of Nonfouling Surfaces
Dalsin, J. L., Hu, B.-H., Lee, B. P., & Messersmith, P. B. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0284963 · Cited by 585 · cited 1×
“Combined treatments, such as ECM protein along with plasma treatment, chemical modification with ECM protein, and/or treating with different chemical reagents have attracted significant attention, and showed a higher success rate for cell attachment than individual treatment [19,35,37,49,52,64,66,86].”
Background
Research works printed but not linked: 1
- Jiang X.Y. Zheng W.F. Takayama S. Chapman R.G. Kane R.S. Whitesides G.M. Chapter Ninteen - Micro-Scale Patterning of Cells and Their Environment Principles of Tissue Engineering 3rd ed. Lanza R. Langer R. Vacanti J. Academic Press Burlington, VT, USA 2007 265 278
Cited by
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
“For example, when endothelial cell seeding is needed, hydrophilic modification of the PDMS surface is indispensable for a successful seeding [103].”
BackgroundPolydimethylsiloxane Composites Characterization and Its Applications: A Review
Ariati, R., Sales, F., Souza, A., Lima, R. A., & Ribeiro, J. (2021) · Polymers · doi:10.3390/polym13234258 · Cited by 440
Advances in haemostatic sponges: Characteristics and the underlying mechanisms for rapid haemostasis
Nepal, A., Nguyen, D. H. T., Nguyen, N., & Ta, H. T. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.008 · Cited by 212
Self-citationHydrogels as artificial matrices for cell seeding in microfluidic devices
Akther, F., Little, P., Li, Z., Nguyen, N.-T., & Ta, H. T. (2020) · RSC Advances · doi:10.1039/d0ra08566a · Cited by 127
Self-citationA Review of Methods to Modify the PDMS Surface Wettability and Their Applications
Neves, L. B., Afonso, I. S., Nóbrega, G., Barbosa, L. G., Lima, R. A., & Ribeiro, J. (2024) · Micromachines · doi:10.3390/mi15060670 · Cited by 148
“The CA, in general, is inversely related to the roughness of the film, especially when it comes to hydrophilic surfaces, where the apparent CA is less than 90 ◦ [78].”
Background
Metadata
- Authors
- Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T.
- Affiliations
- Griffith University (AU)
- The University of Queensland (AU)
- Corresponding author
- Ta, Hang T.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2020-11-19
- Volume
- 10
- Issue
- 11
- Pages
- 182
- ISSN
- 2079-6374 (ISSN-L)
- PMC
- PMC7699314
- OpenAlex
- W3102976653
- Cited by
- 182
- References
- 88
- Citations by year
- 2026: 20 · 2025: 29 · 2024: 35 · 2023: 43 · 2022: 33 · 2021: 21 · 2020: 1
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Biosensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Griffith Research Online (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Health and Medical Research Council (APP1037310, APP1182347)
- Heart Foundation (102761)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Keywords
- PDMS surface modification, endothelial cell seeding, hydrophilic modification, hydrophobicity, microfluidic cell culture, lab-on-a-chip, biomolecule adsorption, endothelialization
- MeSH terms
- Adsorption, Dimethylpolysiloxanes, Humans, Permeability, Cell Culture Techniques, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices, Hydrophobic and Hydrophilic Interactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.