Surface Modification Techniques for Endothelial Cell Seeding in PDMS Microfluidic Devices
Open accessThe DOI matches its Crossref record; 88 of the 88 references it cites were found in a registry or an index.
Abstract
Microfluidic lab-on-a-chip cell culture techniques have been gaining popularity by offering the possibility of reducing the amount of samples and reagents and greater control over cellular microenvironment. Polydimethylsiloxane (PDMS) is the commonly used polymer for microfluidic cell culture devices because of the cheap and easy fabrication techniques, non-toxicity, biocompatibility, high gas permeability, and optical transparency. However, the intrinsic hydrophobic nature of PDMS makes cell seeding challenging when applied on PDMS surface. The hydrophobicity of the PDMS surface also allows the non-specific absorption/adsorption of small molecules and biomolecules that might affect the cellular behaviour and functions. Hydrophilic modification of PDMS surface is indispensable for successful cell seeding. This review collates different techniques with their advantages and disadvantages that have been used to improve PDMS hydrophilicity to facilitate endothelial cells seeding in PDMS devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cell-laden microengineered gelatin methacrylate hydrogels
Nichol, J. W., Koshy, S. T., Bae, H., Hwang, C. M., Yamanlar, S., & Khademhosseini, A. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.03.064 · Cited by 2,377 · cited 1×
“HUVECs shows strong adhesion to PDMS coated with gelatin under flow [45,46].”
BackgroundSoft lithography for micro- and nanoscale patterning
Qin, D., Xia, Y., & Whitesides, G. M. (2010) · Nature Protocols · doi:10.1038/nprot.2009.234 · Cited by 2,334
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
The extracellular matrix in development and morphogenesis: A dynamic view
Rozario, T., & DeSimone, D. W. (2010) · Developmental Biology · doi:10.1016/j.ydbio.2009.10.026 · Cited by 1,451
Characterization of Polydimethylsiloxane (PDMS) Properties for Biomedical Micro/Nanosystems
Mata, A., Fleischman, A. J., & Roy, S. (2005) · Biomedical Microdevices · doi:10.1007/s10544-005-6070-2 · Cited by 1,318
PDMS absorption of small molecules and consequences in microfluidic applications
Toepke, M. W., & Beebe, D. J. (2006) · Lab on a Chip · doi:10.1039/b612140c · Cited by 1,190
Real-time deformability cytometry: on-the-fly cell mechanical phenotyping
Otto, O., Rosendahl, P., Mietke, A., Golfier, S., Herold, C., Klaue, D., Girardo, S., Pagliara, S., Ekpenyong, A., Jacobi, A., et al. (2015) · Nature Methods · doi:10.1038/nmeth.3281 · Cited by 736
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Bodas, D., & Khan-Malek, C. (2007) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2006.08.037 · Cited by 600
Mussel Adhesive Protein Mimetic Polymers for the Preparation of Nonfouling Surfaces
Dalsin, J. L., Hu, B.-H., Lee, B. P., & Messersmith, P. B. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0284963 · Cited by 585
Palchesko, R. N., Zhang, L., Sun, Y., & Feinberg, A. W. (2012) · PLoS ONE · doi:10.1371/journal.pone.0051499 · Cited by 559
Wong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
Gale, B. K., Jafek, A. R., Lambert, C. J., Goenner, B. L., Moghimifam, H., Nze, U. C., & Kamarapu, S. K. (2018) · Inventions · doi:10.3390/inventions3030060 · Cited by 511
Microfluidic 3D cell culture: from tools to tissue models
van Duinen, V., Trietsch, S. J., Joore, J., Vulto, P., & Hankemeier, T. (2015) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2015.05.002 · Cited by 500
Lab-on-a-chip devices: How to close and plug the lab?
Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.10.013 · Cited by 475
Solvent-Resistant Photocurable “Liquid Teflon” for Microfluidic Device Fabrication
Rolland, J. P., Van Dam, R. M., Schorzman, D. A., Quake, S. R., & DeSimone, J. M. (2004) · Journal of the American Chemical Society · doi:10.1021/ja031657y · Cited by 440
Fuard, D., Tzvetkova-Chevolleau, T., Decossas, S., Tracqui, P., & Schiavone, P. (2008) · Microelectronic Engineering · doi:10.1016/j.mee.2008.02.004 · Cited by 424
Compatibility of Mammalian Cells on Surfaces of Poly(dimethylsiloxane)
Lee, J. N., Jiang, X., Ryan, D., & Whitesides, G. M. (2004) · Langmuir · doi:10.1021/la048562+ · Cited by 379
Microfluidic 3D Cell Culture: Potential Application For Tissue-Based Bioassays
Li, X. (., Valadez, A. V., Zuo, P., & Nie, Z. (2012) · Bioanalysis · doi:10.4155/bio.12.133 · Cited by 319
Microfluidic platforms for mechanobiology
Polacheck, W. J., Li, R., Uzel, S. G. M., & Kamm, R. D. (2013) · Lab on a Chip · doi:10.1039/c3lc41393d · Cited by 272 · cited 2×
“The in egr t on of microfluidic in c ll culture provides an in ivo like platform to regulate the mechanobiological respons s on chips [77].”
BackgroundMethodGökaltun, A., Kang, Y. B., Yarmush, M. L., Usta, O. B., & Asatekin, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-43625-5 · Cited by 269
Micromolded gelatin hydrogels for extended culture of engineered cardiac tissues
McCain, M. L., Agarwal, A., Nesmith, H. W., Nesmith, A. P., & Parker, K. K. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.03.052 · Cited by 237
Noise Facilitates Transcriptional Control under Dynamic Inputs
Kellogg, R. A., & Tay, S. (2015) · Cell · doi:10.1016/j.cell.2015.01.013 · Cited by 213
Kuddannaya, S., Chuah, Y. J., Lee, M. H. A., Menon, N. V., Kang, Y., & Zhang, Y. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am402903e · Cited by 209
Paguirigan, A. L., & Beebe, D. J. (2008) · BioEssays · doi:10.1002/bies.20804 · Cited by 208
Gokaltun, A., Yarmush, M. L., Asatekin, A., & Usta, O. B. (2017) · TECHNOLOGY · doi:10.1142/s2339547817300013 · Cited by 183
A circular cross-section PDMS microfluidics system for replication of cardiovascular flow conditions
Fiddes, L. K., Raz, N., Srigunapalan, S., Tumarkan, E., Simmons, C. A., Wheeler, A. R., & Kumacheva, E. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.082 · Cited by 170
Wang, X.-Y., Jin, Z.-H., Gan, B.-W., Lv, S.-W., Xie, M., & Huang, W.-H. (2014) · Lab Chip · doi:10.1039/c4lc00069b · Cited by 166
Su, W., Cook, B. S., Fang, Y., & Tentzeris, M. M. (2016) · Scientific Reports · doi:10.1038/srep35111 · Cited by 162
Matrix-dependent adhesion of vascular and valvular endothelial cells in microfluidic channels
Young, E. W. K., Wheeler, A. R., & Simmons, C. A. (2007) · Lab on a Chip · doi:10.1039/b712486d · Cited by 159
PDMS-Based Microfluidic Devices for Cell Culture
Torino, S., Corrado, B., Iodice, M., & Coppola, G. (2018) · Inventions · doi:10.3390/inventions3030065 · Cited by 157
van der Meer, A. D., Orlova, V. V., ten Dijke, P., van den Berg, A., & Mummery, C. L. (2013) · Lab on a Chip · doi:10.1039/c3lc50435b · Cited by 150
High-Content Quantification of Single-Cell Immune Dynamics
Junkin, M., Kaestli, A. J., Cheng, Z., Jordi, C., Albayrak, C., Hoffmann, A., & Tay, S. (2016) · Cell Reports · doi:10.1016/j.celrep.2016.03.033 · Cited by 142
van Engeland, N. C. A., Pollet, A. M. A. O., den Toonder, J. M. J., Bouten, C. V. C., Stassen, O. M. J. A., & Sahlgren, C. M. (2018) · Lab on a Chip · doi:10.1039/c8lc00286j · Cited by 140
The effects of poly(dimethylsiloxane) surface silanization on the mesenchymal stem cell fate
Chuah, Y. J., Kuddannaya, S., Lee, M. H. A., Zhang, Y., & Kang, Y. (2015) · Biomaterials Science · doi:10.1039/c4bm00268g · Cited by 128
Vascular endothelial cell mechanosensing: New insights gained from biomimetic microfluidic models
Gray, K. M., & Stroka, K. M. (2017) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2017.06.002 · Cited by 120
Zanotelli, M. R., Ardalani, H., Zhang, J., Hou, Z., Nguyen, E. H., Swanson, S., Nguyen, B. K., Bolin, J., Elwell, A., Bischel, L. L., et al. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.03.001 · Cited by 106
Razafiarison, T., Holenstein, C. N., Stauber, T., Jovic, M., Vertudes, E., Loparić, M., Kawecki, M., Bernard, L., Silván, U., & Snedeker, J. G. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1704543115 · Cited by 95
Chumbimuni-Torres, K. Y., Coronado, R. E., Mfuh, A. M., Castro-Guerrero, C., Silva, M. F., Negrete, G. R., Bizios, R., & Garcia, C. D. (2011) · RSC Advances · doi:10.1039/c1ra00198a · Cited by 92
Improved cell adhesion under shear stress in PDMS microfluidic devices
Siddique, A., Meckel, T., Stark, R. W., & Narayan, S. (2016) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2016.11.011 · Cited by 92
Studying Cancer Stem Cell Dynamics on PDMS Surfaces for Microfluidics Device Design
Zhang, W., Choi, D. S., Nguyen, Y., Chang, J. C., & Qin, L. (2013) · Scientific Reports · doi:10.1038/srep02332 · Cited by 89
Booth, R., Noh, S., & Kim, H. (2014) · Lab Chip · doi:10.1039/c3lc51304a · Cited by 87
Jena, R. K., & Yue, C. Y. (2012) · Biomicrofluidics · doi:10.1063/1.3682098 · Cited by 84
Park, S. E., Georgescu, A., Oh, J. M., Kwon, K. W., & Huh, D. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b07912 · Cited by 83
Convenient Method for Modifying Poly(dimethylsiloxane) with Poly(ethylene glycol) in Microfluidics
Zhou, J., Yan, H., Ren, K., Dai, W., & Wu, H. (2009) · Analytical Chemistry · doi:10.1021/ac900551m · Cited by 79
Ranjan, A., & Webster, T. J. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/30/305102 · Cited by 75
Characterization of In Vitro Endothelial Linings Grown Within Microfluidic Channels
Esch, M. B., Post, D. J., Shuler, M. L., & Stokol, T. (2011) · Tissue Engineering Part A · doi:10.1089/ten.tea.2010.0371 · Cited by 74
Functionalisation of Polydimethylsiloxane (PDMS)- Microfluidic Devices coated with Rock Minerals
Alzahid, Y. A., Mostaghimi, P., Gerami, A., Singh, A., Privat, K. L., Amirian, T., & Armstrong, R. T. (2018) · Scientific Reports · doi:10.1038/s41598-018-33495-8 · Cited by 73
Trinh, K. T. L., Thai, D. A., Chae, W. R., & Lee, N. Y. (2020) · ACS Omega · doi:10.1021/acsomega.0c01770 · Cited by 67
Nishikawa, M., Yamamoto, T., Kojima, N., Komori, K., Fujii, T., & Sakai, Y. (2007) · Biotechnology and Bioengineering · doi:10.1002/bit.21690 · Cited by 66
Viable cell culture in PDMS-based microfluidic devices
Tanyeri, M., & Tay, S. (2018) · Methods in cell biology · doi:10.1016/bs.mcb.2018.09.007 · Cited by 62
Gezer, P. G., Brodsky, S., Hsiao, A., Liu, G. L., & Kokini, J. L. (2015) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2015.07.006 · Cited by 57
Direct Writing of Microfluidic Footpaths by Pyro-EHD Printing
Coppola, S., Nasti, G., Todino, M., Olivieri, F., Vespini, V., & Ferraro, P. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b02633 · Cited by 56
A microfluidic chip with gravity‐induced unidirectional flow for perfusion cell culture
Lee, D. W., Choi, N., & Sung, J. H. (2019) · Biotechnology Progress · doi:10.1002/btpr.2701 · Cited by 54
Zargar, R., Nourmohammadi, J., & Amoabediny, G. (2015) · Biotechnology and Applied Biochemistry · doi:10.1002/bab.1371 · Cited by 48
Elucidating in vitro cell-cell interaction using a microfluidic coculture system
Wei, C., Cheng, J., & Young, T. (2006) · Biomedical Microdevices · doi:10.1007/s10544-006-6384-8 · Cited by 46
Fu, J., Chuah, Y. J., Ang, W. T., Zheng, N., & Wang, D. (2017) · Biomaterials Science · doi:10.1039/c7bm00266a · Cited by 44
Fibronectin coating of oxygenator membranes enhances endothelial cell attachment
Cornelissen, C. G., Dietrich, M., Gromann, K., Frese, J., Krueger, S., Sachweh, J. S., & Jockenhoevel, S. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-7 · Cited by 42
A Microfluidic System for the Investigation of Tumor Cell Extravasation
Kühlbach, C., Da Luz, S., Baganz, F., Hass, V. C., & Mueller, M. M. (2018) · Bioengineering · doi:10.3390/bioengineering5020040 · Cited by 38
Jastrzębska, E., Żuchowska, A., Flis, S., Sokołowska, P., Bułka, M., Dybko, A., & Brzózka, Z. (2018) · Biomicrofluidics · doi:10.1063/1.5035176 · Cited by 38
Adhesion of MRC‐5 and A549 cells on poly(dimethylsiloxane) surface modified by proteins
Żuchowska, A., Kwiatkowski, P., Jastrzębska, E., Chudy, M., Dybko, A., & Brzózka, Z. (2015) · Electrophoresis · doi:10.1002/elps.201500250 · Cited by 36
Rapid and Robust Coating Method to Render Polydimethylsiloxane Surfaces Cell-Adhesive
Gehlen, D. B., Novaes, L. C. D. L., Long, W., Ruff, A. J., Jakob, F., Haraszti, T., Chandorkar, Y., Yang, L., van Rijn, P., Schwaneberg, U., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b16025 · Cited by 35
Wu, C.-C., Yuan, C.-Y., & Ding, S. (2010) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2010.11.036 · Cited by 34
Mikhail, A. S., Ranger, J. J., Liu, L., Longenecker, R. J., Thompson, D. B., Sheardown, H. D., & Brook, M. A. (2010) · Journal of Biomaterials Science Polymer Edition · doi:10.1163/156856209x445311 · Cited by 33
Khetani, S., Yong, K. W., Kollath, V. O., Eastick, E., Azarmanesh, M., Karan, K., Sen, A., & Sanati‐Nezhad, A. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b20826 · Cited by 33
Rapid Prototyping of a Cyclic Olefin Copolymer Microfluidic Device for Automated Oocyte Culturing
Berenguel‐Alonso, M., Sabés‐Alsina, M., Morató, R., Ymbern, O., Rodríguez-Vázquez, L., Talló-Parra, O., Alonso, J., Puyol, M., & López‐Béjar, M. (2017) · SLAS TECHNOLOGY · doi:10.1177/2472630316684625 · Cited by 33
Chan, C. Y., Goral, V. N., DeRosa, M. E., Huang, T. J., & Yuen, P. K. (2014) · Biomicrofluidics · doi:10.1063/1.4894409 · Cited by 31
On-Chip Fabrication of a Cell-Derived Extracellular Matrix Sheet
Hong, Y., Koh, I., Park, K., & Kim, P. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b00613 · Cited by 30
Sivarapatna, A., Ghaedi, M., Xiao, Y., Han, E. X., Aryal, B. K., Zhou, J. H., Fernandez-Hernando, C. F., Qyang, Y., Hirschi, K. K., & Niklason, L. E. (2017) · Cell Transplantation · doi:10.1177/0963689717720282 · Cited by 26
Perikamana, S. K. M., Shin, Y. M., Lee, J. K., Lee, Y. B., Heo, Y., Ahmad, T., Park, S. Y., Shin, J., Park, K. M., Jung, H. S., et al. (2017) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2017.08.022 · Cited by 26
Application of polydopamine in biomedical microfluidic devices
Kanitthamniyom, P., & Zhang, Y. (2018) · Microfluidics and Nanofluidics · doi:10.1007/s10404-018-2044-6 · Cited by 25
Transcribing In Vivo Blood Vessel Networks into In Vitro Perfusable Microfluidic Devices
Chen, Y. Y., Kingston, B. R., & Chan, W. C. W. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000103 · Cited by 25
Chung, S. H., & Min, J. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.03.041 · Cited by 23
Aymerich, M., Gomez-Varela, A. I., Álvarez, E., & Flores-Arias, M. T. (2016) · Materials · doi:10.3390/ma9090728 · Cited by 22
Integrating 3D cell culture of PC12 cells with microchip-based electrochemical detection
Mehl, B. T., & Martin, R. S. (2019) · Analytical Methods · doi:10.1039/c8ay02672f · Cited by 22
Spuul, P., Chi, P., Billottet, C., Chou, C., & Genot, E. M. (2015) · Methods · doi:10.1016/j.ymeth.2015.09.001 · Cited by 21
Shi, W., Reid, L., Huang, Y., Uhl, C. G., He, R., Zhou, C., & Liu, Y. (2019) · Biomicrofluidics · doi:10.1063/1.5108681 · Cited by 21
Leivo, J., Virjula, S., Vanhatupa, S., Kartasalo, K., Kreutzer, J., Miettinen, S., & Kallio, P. J. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0318 · Cited by 20
Electrohydrodynamic inkjet printing of Polydimethylsiloxane (PDMS)
Jiang, L., Huang, Y., Zhang, X., & Qin, H. (2020) · Procedia Manufacturing · doi:10.1016/j.promfg.2020.05.024 · Cited by 17
Chiang, H.-J., Yeh, S.-L., Peng, C., Liao, W., & Tung, Y. (2017) · Journal of Visualized Experiments · doi:10.3791/55292 · Cited by 16
Effect of Silicone on the Collagen Fibrillogenesis and Stability
Kadziński, L., Prokopowicz, M., Jakóbkiewicz‐Banecka, J., Gabig‐Cimińska, M., Łukasiak, J., & Banecki, B. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24351 · Cited by 14
Hellmann, A., Klein, S., Hesselmann, F., Djeljadini, S., Schmitz‐Rode, T., Jockenhoevel, S., Cornelissen, C. G., & Thiebes, A. L. (2020) · Artificial Organs · doi:10.1111/aor.13712 · Cited by 13
Chiang, H.-J., Yeh, S.-L., Peng, C., Liao, W., & Tung, Y. (2017) · Journal of Visualized Experiments · doi:10.3791/55292-v · Cited by 11
Nourmohammadi, J., Hajibabaei, T., Amoabediny, G., Jafari, S. H., & Salehi‐Nik, N. (2015) · Trends in Biomaterials and Artificial Organs · Cited by 10
A perforated microhole-based microfluidic device for improving sprouting angiogenesis in vitro
Chen, S., Zhang, L., Zhao, Y., Ke, M., Li, B., Chen, L., & Cai, S. (2017) · Biomicrofluidics · doi:10.1063/1.4994599 · Cited by 9
A multichannel acoustically driven microfluidic chip to study particle-cell interactions
Wang, X., Fillafer, C., Pichl, C., Deinhammer, S., Hofer-Warbinek, R., Wirth, M., & Gabor, F. (2013) · Biomicrofluidics · doi:10.1063/1.4819273 · Cited by 6
Capillary Differentiation of Endothelial Cells on Microgrooved Surfaces
Wang, H., Chen, S., Ratner, B. D., Sage, E. H., & Jiang, S. (2007) · The Journal of Physical Chemistry C · doi:10.1021/jp075746z · Cited by 6
Sfriso, R., & Rieben, R. (2020) · Methods in molecular biology · doi:10.1007/978-1-0716-0255-3_6 · Cited by 4
Research works printed but not linked: 1
- Lanza, R., Langer, R., and Vacanti, J. (2007). Chapter Ninteen - Micro-Scale Patterning of Cells and Their Environment. Principles of Tissue Engineering, Academic Press. [3rd ed.].
Cited by
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Polydimethylsiloxane Composites Characterization and Its Applications: A Review
Ariati, R., Sales, F., Souza, A., Lima, R. A., & Ribeiro, J. (2021) · Polymers · doi:10.3390/polym13234258 · Cited by 440
Advances in haemostatic sponges: Characteristics and the underlying mechanisms for rapid haemostasis
Nepal, A., Nguyen, D. H. T., Nguyen, N., & Ta, H. T. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.008 · Cited by 160
Self-citationHydrogels as artificial matrices for cell seeding in microfluidic devices
Akther, F., Little, P., Li, Z., Nguyen, N.-T., & Ta, H. T. (2020) · RSC Advances · doi:10.1039/d0ra08566a · Cited by 127
Self-citationA Review of Methods to Modify the PDMS Surface Wettability and Their Applications
Neves, L. B., Afonso, I. S., Nóbrega, G., Barbosa, L. G., Lima, R. A., & Ribeiro, J. (2024) · Micromachines · doi:10.3390/mi15060670 · Cited by 127
Metadata
- Authors
- Akther, F., Yakob, S. B., Nguyen, N.-T., & Ta, H. T.
- Affiliations
- Griffith University (AU)
- The University of Queensland (AU)
- Corresponding author
- Ta, Hang T.
- Venue
- Biosensors
- Publisher
- MDPI AG
- Published
- 2020-11-19
- Volume
- 10
- Issue
- 11
- Pages
- 182
- ISSN
- 2079-6374 (ISSN-L)
- PMC
- PMC7699314
- OpenAlex
- W3102976653
- Cited by
- 182
- References
- 88
- Citations by year
- 2026: 20 · 2025: 29 · 2024: 35 · 2023: 43 · 2022: 33 · 2021: 21 · 2020: 1
- FWCI
- 2.05
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Biosensors (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Griffith Research Online (submittedVersion, cc-by)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- National Health and Medical Research Council (APP1037310, APP1182347)
- Heart Foundation (102761)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Materials Science › Surfaces, Coatings and Films › Polymer Surface Interaction Studies
- Keywords
- PDMS surface modification, endothelial cell seeding, hydrophilic modification, hydrophobicity, microfluidic cell culture, lab-on-a-chip, biomolecule adsorption, endothelialization
- MeSH terms
- Adsorption, Dimethylpolysiloxanes, Humans, Permeability, Cell Culture Techniques, Microfluidic Analytical Techniques, Lab-On-A-Chip Devices, Hydrophobic and Hydrophilic Interactions
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.