Establishment of Local Diagnostic Reference Levels for Head CT Imaging in the Madina Region, Saudi Arabia
Open accessAbstract
Background: Computed Tomography (CT) is crucial in medical diagnosis, particularly for head examinations. Diagnostic Reference Levels (DRLs) are pivotal in balancing diagnostic efficacy with radiation safety. International organizations such as the International Atomic Energy Agency (IAEA) and the International Commission on Radiological Protection (ICRP) provide guidelines for establishing DRLs, emphasizing their importance in optimizing radiation doses. Aim: This study aimed to establish and standardize DRLs for head CT imaging in institutional and regional settings, emphasizing the need for tailored reference levels specific to each region’s practices and standards. Method: Data collection included patient demographics, imaging parameters, and radiation dose indices, namely volume-weighted CT dose index (CTDIvol) and dose-length product (DLP). Statistical analyses were conducted to determine the median and 3rd quartile values for establishing DRLs. The results were compared with national and international benchmarks to assess variations in radiation doses across regions. Results: Demographic profiles detailed gender distributions and ages across hospitals. Imaging parameters exhibited variability in tube voltage, milliampere-seconds (mAs), pitch, scan length, and field of view (FOV). For CTDIvol, the 3rd quartile value was 65.8 mGy (range: 24.8–85.9 mGy), and for DLP, it was 1230.95 mGy·cm (range: 382.3–1189.0 mGy·cm). These values were slightly higher than the national DRLs for Saudi Arabia in 2021 and other international benchmarks, underscoring the need for further optimization and alignment of protocols. Conclusion: Optimizing and standardizing DRLs for head CT imaging is crucial for effectively managing radiation doses while ensuring diagnostic accuracy. Comparison with national and international benchmarks highlighted the importance of tailoring reference levels to regional practices and standards, ensuring patient safety without compromising diagnostic efficacy.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A DRL is computed as the 75th percentile of the distribution of median dosages among facilities.
“Upon the accumulation of adequate data, the 75th percentile (third quartile) of the distribution of median dosages among facilities is computed.78”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [78]
The Introduction (page unavailable) says DRLs are typically set at the 75th percentile of doses observed in a large sample of patients. Section 3.5 (page unavailable) discusses hospital median doses, but does not say to calculate the 75th percentile of those medians across facilities. The claim combines two elements the paper describes separately. (LLM, conf=0.86)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355 · see citing works
ICRP Publication 135: Diagnostic Reference Levels in Medical Imaging
Vañó, E., Miller, D. L., Martin, C. J., Rehani, M. M., Kang, K., Rosenstein, M., Ortiz-López, P., Mattsson, S., Padovani, R., & Rogers, A. (2017) · Annals of the ICRP · doi:10.1177/0146645317717209 · Cited by 1,043 · see citing works
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan, M., Coombs, L. P., & Morin, R. L. (2017) · Radiology · doi:10.1148/radiol.2017161911 · Cited by 397 · see citing works
Matsunaga, Y., Chida, K., Kondo, Y., et al. (2018) · British Journal of Radiology · doi:10.1259/bjr.20180290 · Cited by 65 · see citing works
Ekpo, E. U., Adejoh, T., Akwo, J. D., Emeka, O. C., Modu, A. A., Abba, M., Adesina, K. A., Omiyi, D. O., & Chiegwu, U. H. (2018) · Journal of Radiological Protection · doi:10.1088/1361-6498/aaaaf8 · Cited by 61 · see citing works
Abuzaid, M., Elshami, W., Tekin, H. O., et al. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00891-6 · Cited by 30 · see citing works
Self-citationErem, G., Ameda, F., Otike, C., Olwit, W., Mubuuke, A. G., Schandorf, C., Kisolo, A., & Kawooya, M. G. (2022) · BMC Medical Imaging · doi:10.1186/s12880-022-00838-x · Cited by 22 · see citing works
Osman, H., Alosaimi, M., Alghamdi, F., et al. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110206 · Cited by 22 · see citing works
Abuzaid, M., Elshami, W., Serafi, A. E., et al. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa100 · Cited by 20 · see citing works
Self-citationEstablishing diagnostic reference levels for CT examinations in the south region of Saudi Arabia
Alashban, Y. I., & Shubayr, N. (2022) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2022.110407 · Cited by 19 · see citing works
Kumamaru, K. K., Kogure, Y., Suzuki, M., et al. (2016) · Japanese Journal of Radiology · doi:10.1007/s11604-016-0545-3 · Cited by 11 · see citing works
Elmahdi, A., Abuzaid, M., Babikir, E., & Sulieman, A. (2018) · Polish Journal of Radiology · doi:10.12659/pjr.902502 · Cited by 10 · see citing works
Self-citationDiagnostic Reference Levels: A Review
Bali, A. T. R. D. R. (., & Wulandari, P. I. (2018) · Journal of Medical Science And clinical Research · doi:10.18535/jmscr/v6i12.80 · Cited by 9 · see citing works
DIAGNOSTIC REFERENCE LEVELS OF RADIOGRAPHIC AND CT EXAMINATIONS IN SAUDI ARABIA: A SYSTEMATIC REVIEW
Alrehily, F. A. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac183 · Cited by 9 · see citing works
Saeed, M. K., Alzoubi, A. S., & Alqahtani, J. M. (2014) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-014-0256-y · Cited by 7 · see citing works
Establishment of Computed Tomography Diagnostic Reference Levels in Tobruk
Bolowia, N. F. A. (2018) · Journal of Medical Diagnostic Methods · doi:10.4172/2168-9784.1000274 · Cited by 6 · see citing works
Towards the Establishment of Diagnostic Reference Levels in Saudi Arabia: Review and Opinion
Aloufi, K. M., Alhazmi, F. H., Abdulaal, O. M., et al. (2021) · Egyptian Journal of Radiation Sciences and Applications · doi:10.21608/ejrsa.2021.55201.1111 · Cited by 6 · see citing works
Alkhybari, E. M., Alhulail, A. A., Sulieman, A., et al. (2022) · Journal of Radiation Research and Applied Sciences · doi:10.1016/j.jrras.2022.08.011 · Cited by 6 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W. (2026) · Drug, Healthcare and Patient Safety · doi:10.2147/dhps.s595721
- Authors
- Alhujaili, S. F., Alshabibi, A. S., Alafer, F., Alrowaili, Z., Salah, H., Sulieman, A., Subahi, M., Al-Raddadi, K., & Abuzaid, M.
- Affiliations
- Jouf University (SA)
- King Saud University (SA)
- Nuclear Medicine Department, Inaya Medical College, Riyadh 13541, Saudi Arabia
- King Saud bin Abdulaziz University for Health Sciences (SA)
- Ministry of Health (SA)
- University of Sharjah (AE)
- Corresponding author
- Abuzaid, Mohamed
- ORCID
- Venue
- Diagnostics
- Publisher
- MDPI AG
- Published
- 2024-12-21
- Volume
- 14
- Issue
- 24
- Pages
- 2882
- ISSN
- 2075-4418 (ISSN-L)
- PMC
- PMC11675420
- OpenAlex
- W4405699577
- Cited by
- 7
- References
- 18
- Citations by year
- 2026: 6 · 2025: 1
- FWCI
- 1.78
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- Diagnostics (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Keywords
- diagnostic reference levels, head CT, radiation dose optimization, dose-length product, patient radiation protection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review