Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 67

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Investigation of a Novel 24-Slot/14-Pole Six-Phase Fault-Tolerant Modular Permanent-Magnet In-Wheel Motor for Electric Vehicles

Zheng, Ping, Wu, Fan, Lei, Yu, Sui, Yi, Yu, Bin · 2013 · Energies

Abstract

In this paper, a six-phase fault-tolerant modular permanent magnet synchronous machine (PMSM) with a novel 24-slot/14-pole combination is proposed as a high-performance actuator for wheel-driving electric vehicle (EV) applications. Feasible slot/pole combinations of the fractional-slot concentrated winding six-phase PMSM are elicited and analyzed for scheme selection. The novel 24-slot/14-pole combination is derived from the analysis and suppression of the magnetomotive force (MMF) harmonics. By making use of alternate-teeth-wound concentrated winding configuration, two adjacent coils per phase and unequal teeth widths, the phase windings of the proposed machine is magnetically, thermally isolated, which offers potentials of modular design and fault tolerant capability. Taking advantage of the leakage component of winding inductance, 1.0 per unit short-circuit current is achieved endowing the machine with short-circuit proof capability. Optimal design of essential parameters aiming at low eddy current losses, high winding factor and short-circuit-proof ability are presented to pave the way for a high-quality system implementation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3390/en6104980

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 35

  1. Wang, 2013, Design optimization of a surface-mounted permanent-magnet motor with concentrated windings for electric vehicle applications, IEEE Trans. Veh. Technol., 62, 1053, 10.1109/TVT.2012.2227867 · DOI · Paper page
  2. Nikam, 2012, A high-torque-density permanent-magnet free motor for in-wheel electric vehicle application, IEEE Trans. Ind. Appl., 48, 2287, 10.1109/TIA.2012.2227053 · doi:10.1109/tia.2012.2227053
  3. Wang, 2008, Modular three-phase permanent-magnet brushless machines for in-wheel applications, IEEE Trans. Veh. Technol., 57, 2714, 10.1109/TVT.2007.914476 · doi:10.1109/tvt.2007.914476
  4. Jack, 1996, A comparative study of permanent magnet and switched reluctance motors for high-performance fault-tolerant applications, IEEE Trans. Ind. Appl., 32, 889, 10.1109/28.511646 · DOI · Paper page
  5. Fasolo, A., Alberti, L., and Bianchi, N. (2012, January 2–5). Performance Comparison between Switching-Flux and IPM Machine with Rare Earth and Ferrite PMs. Proceedings of the XXth IEEE International Conference on Electric Machines (ICEM), Marseille, France. · doi:10.1109/icelmach.2012.6349955
  6. 2011, Fault-tolerant permanent magnet machines: A review, IET Electr. Power Appl., 5, 59, 10.1049/iet-epa.2009.0117 · DOI · Paper page
  7. Chung, 2012, Fractional slot concentrated winding permanent magnet synchronous machine with consequent pole rotor for low speed direct drive, IEEE Trans. Magn., 48, 2965, 10.1109/TMAG.2012.2196417 · doi:10.1109/tmag.2012.2196417
  8. Reddy, 2012, Comparison of interior and surface PM machines equipped with fractional-slot concentrated windings for hybrid traction applications, IEEE Trans. Energy Convers., 27, 593, 10.1109/TEC.2012.2195316 · DOI · Paper page
  9. 2010, Fractional-slot concentrated-windings synchronous permanent magnet machines: Opportunities and challenges, IEEE Trans. Ind. Electron., 57, 107, 10.1109/TIE.2009.2030211 · DOI · Paper page
  10. Chen, 2010, Winding configurations and optimal stator and rotor pole combination of flux-switching PM brushless AC machines, IEEE Trans. Energy Convers., 25, 293, 10.1109/TEC.2009.2032633 · doi:10.1109/tec.2009.2032633
  11. Ishak, 2005, Permanent-magnet brushless machines with unequal tooth widths and similar slot and pole numbers, IEEE Trans. Ind. Appl., 41, 584, 10.1109/TIA.2005.844380 · DOI · Paper page
  12. Welchko, 2004, Fault tolerant three-phase AC motor drive topologies: A comparison of features, cost, and limitations, IEEE Trans. Power Electron., 19, 1008, 10.1109/TPEL.2004.830074 · DOI · Paper page
  13. Abolhassani, M.T., and Toliyat, H.A. (2009, January 3–5). Fault Tolerant Permanent Magnet Motor Drives for Electric Vehicles. Proceedings of the IEEE International Conference on Electric Machines and Drives, Miami, FL, USA. · DOI
  14. Jussila, H., Salminen, P., Niemela, M., and Pyrhonen, J. (2007, January 12–14). Guidelines for Designing Concentrated Winding Fractional Slot Permanent Magnet Machines. Proceedings of the International Conference on Power Engineering, Setubal, Portugal. · DOI
  15. Reddy, P.B., Jahns, T.M., and EL-Refaie, A.M. (2008, January 5–9). Impact of Winding Layer Number and Slot/Pole Combination on AC Armature Losses of Synchronous Surface PM Machines Designed for Wide Constant-Power Speed Range Operation. Proceedings of the IEEE Industry Applications Society Annual Meeting (IAS), Edmonton, AB, Canada. · doi:10.1109/08ias.2008.57
  16. Bianchi, 2006, Design considerations for fractional-slot winding configurations of synchronous machines, IEEE Trans. Ind. Appl., 42, 997, 10.1109/TIA.2006.876070 · DOI · Paper page
  17. EL-Refaie, A.M., Zhu, Z.Q., Jahns, T.M., and Howe, D. (2008, January 5–9). Winding Inductances of Fractional Slot Surface-Mounted Permanent Magnet Brushless Machines. Proceedings of the IEEE Industry Applications Society Annual Meeting (IAS), Edmonton, AB, Canada. · DOI
  18. Zheng, 2012, Harmonic analysis and fault-tolerant capability of a semi-12-phase permanent-magnet synchronous machine used for EVs, Energies, 5, 3586, 10.3390/en5093586 · doi:10.3390/en5093586
  19. Tangudu, J.K., Jahns, T.M., and Bohn, T.P. (2011, January 17–22). Design, Analysis and Loss Minimization of a Fractional-Slot Concentrated Winding IPM Machine for Traction Applications. Proceedings of the IEEE Energy Conversion Congress and Exposition, Phoenix, AZ, USA. · doi:10.1109/ecce.2011.6064065
  20. Reddy, P.B., Jahns, T.M., McCleer, P.J., and Bohn, T.P. (2010, January 12–16). Design, Analysis and Fabrication of a High Performance Fractional-Slot Concentrated Winding Surface PM Machine. Proceedings of the IEEE Energy Conversion Congress and Exposition, Atlanta, GA, USA. · doi:10.1109/ecce.2010.5617859
  21. Brown, N.R., Jahns, T.M., and Lorenz, R.D. (2007, January 23–27). Power Converter Design for an Integrated Modular Motor Drive. Proceedings of the IEEE 42nd Industry Applications Conference (IAS) Annual Meeting, New Orleans, LA, USA. · DOI
  22. Ouyang, W., Huang, S., Good, A., and Lipo, T.A. (2005, January 27–29). Modular Permanent Magnet Machine Based on Soft Magnetic Composite. Proceedings of the IEEE International Conference on Electric Machines and Drives, Nanjing, China.
  23. Dwari, S., Parsa, L., and Lipo, T.A. (2007, January 17–21). Optimum Control of a Five-Phase Integrated Modular Permanent Magnet Motor under Normal and Open-Circuit Fault Conditions. Proceedings of the IEEE Power Electronics Specialists Conference, Orlando, FL, USA. · doi:10.1109/pesc.2007.4342242
  24. Griva, G., and Oleschuk, V. (2009, January 3–5). Neutral-Point-Clamped Inverters with Hybrid PWM for Symmetrical Six-Phase Motor Drive. Proceedings of the 35th Annual Conference of the IEEE Industrial Electronics Society, Porto, Portugal. · doi:10.1109/iecon.2009.5414998
  25. Prieto, J., Barrero, F., Lim, C.S., and Levi, E. (2012, January 4–6). Predictive Current Control with Modulation in Asymmetrical Six-Phase Motor Drives. Proceedings of the IEEE Power Electronics and Motion Control Conference, Novi Sad, Serbia. · doi:10.1109/epepemc.2012.6397390
  26. Klingshirn, 1983, High phase order induction motors—Parts I and II, IEEE Trans. Power Appar. Syst., 102, 47, 10.1109/TPAS.1983.317996 · doi:10.1109/tpas.1983.317996
  27. Barcaro, 2011, Six-phase supply feasibility using a pm fractional-slot dual winding machine, IEEE Trans. Ind. Appl., 47, 2042, 10.1109/TIA.2011.2161859 · DOI
  28. Magnussen, F., and Sadarangani, C. (2003, January 1–4). Winding Factors and Joule Losses of Permanent Magnet Machines with Concentrated Windings. Proceedings of the IEEE International Electric Machines and Drives Conferences, Madison, WI, USA.
  29. Fornasiero, 2012, Slot harmonic impact on rotor losses in fractional-slot permanent-magnet machines, IEEE Trans. Ind. Electron., 59, 2557, 10.1109/TIE.2011.2168794 · DOI
  30. Bianchi, 2009, Impact of MMF space harmonic on rotor losses in fractional-slot permanent-magnet machines, IEEE Trans. Energy Convers., 24, 323, 10.1109/TEC.2008.2006557 · doi:10.1109/tec.2008.2006557
  31. Cros, 2002, Synthesis of high performance PM motors with concentrated windings, IEEE Trans. Energy Convers., 17, 248, 10.1109/TEC.2002.1009476 · DOI · Paper page
  32. Atallah, 2003, Torque-ripple minimization in modular permanent-magnet brushless machines, IEEE Trans. Ind. Appl., 39, 1689, 10.1109/TIA.2003.818986 · DOI
  33. Ouyang, W. (2007). Modular Permanent Magnet Machine Drive System with Fault Tolerant Capability. [Ph. D. Thesis, University of Wisconsin-Madison].
  34. Ponomarev, 2012, Effect of slot and pole combination on the leakage inductance and the performance of tooth-coil permanent-magnet synchronous machines, IEEE Trans. Ind. Electron., 60, 1
  35. Aslan, B., Semail, E., and Legranger, J. (2012, January 15–20). Analytical Model of Magnet Eddy-Current Volume Losses in Multi-Phase PM Machines with Concentrated Winding. Proceedings of the IEEE Energy Conversion Congress and Exposition, Raleigh, NC, USA. · doi:10.1109/ecce.2012.6342330

Cited by

See all 67

Metadata

Authors
Zheng, P., Wu, F., Lei, Y., Sui, Y., & Yu, B.
Venue
Energies
Publisher
MDPI AG
Published
2013-09-26
Volume
6
Issue
10
Pages
4980-5002
ISSN
1996-1073
Cited by
67
References
2
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.