Effects of SCCO2, Gamma Irradiation, and Sodium Dodecyl Sulfate Treatments on the Initial Properties of Tendon Allografts
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Sterile and decellularized allograft tendons are viable biomaterials used in reconstructive surgeries for dense connective tissue injuries. Established allograft processing techniques including gamma irradiation and sodium dodecyl sulfate (SDS) can affect tissue integrity. Supercritical carbon dioxide (SCCO2) represents a novel alternative that has the potential to decellularize and sterilize tendons with minimized exposure to denaturants, shortened treatment time, lack of toxic residues, and superior tissue penetration, and thus efficacy. This study attempted to develop a single-step hybrid decellularization and sterilization protocol for tendons that involved SCCO2 treatment with various chemical additives. The processed tendons were evaluated with mechanical testing, histology, scanning electron microscopy (SEM), and Fourier-transform infrared (FTIR) spectroscopy. Uniaxial mechanical testing showed that tendons treated with SCCO2 and additive NovaKillTM Gen2 and 0.1% SDS had significantly higher (p < 0.05) ultimate tensile stress (UTS) and Young’s modulus compared to gamma-irradiated and standard-SDS-treated tendons. This was corroborated by the ultrastructural intactness of SCCO2-treated tendons as examined by SEM and FTIR spectroscopy, which was not preserved in gamma-irradiated and standard SDS-treated tendons. However, complete decellularization was not achieved by the experimented SCCO2-SDS protocols used in this study. The present study therefore serves as a concrete starting point for development of an SCCO2-based combined sterilization and decellularization protocol for allograft tendons, where additive choice is to be optimized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Engineering and Regenerative Medicine: History, Progress, and Challenges
Berthiaume, F., Maguire, T. J., & Yarmush, M. L. (2011) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-061010-114257 · Cited by 734 · cited 1×
“In principle, any viable constituents should be removed, or at least deactivated, in the end-product, and the ECM ideally conserved in its intact three-dimensional microarchitecture, which contains naturally occurring collagen, and is responsible for most of its mechanical robustness [87,88].”
BackgroundConsequences of ineffective decellularization of biologic scaffolds on the host response
Keane, T. J., Londono, R., Turner, N. J., & Badylak, S. F. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2011.10.054 · Cited by 613 · cited 3×
“Donor cells and residual DNA have been shown to induce prolonged adverse host inflammatory reactions against allograft tendons in vivo that can lead to clinical inferiority to autografts [13].”
BackgroundInfluentialEpidemiology of musculoskeletal injuries among sedentary and physically active adults
HOOTMAN, J. M., MACERA, C. A., AINSWORTH, B. E., ADDY, C. L., MARTIN, M., & BLAIR, S. N. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200205000-00017 · Cited by 284
Kim, S. H., Jung, Y., & Kim, S. H. (2013) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0170 · Cited by 36 · cited 1×
“SCCO2 has the potential of creating porous scaffolds that are advantageous to cellular attachment [78,103,104], and validating such a possibility is certainly a worthwhile undertaking for future in vivo studies.”
Background
Cited by
Application of decellularized bone matrix as a bioscaffold in bone tissue engineering
Amirazad, H., Dadashpour, M., & Zarghami, N. (2022) · Journal of Biological Engineering · doi:10.1186/s13036-021-00282-5 · Cited by 154
Tao, M., Ao, T., Mao, X., Yan, X., Javed, R., Hou, W., Wang, Y., Sun, C., Lin, S., Yu, T., et al. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2021.02.010 · Cited by 119
Decellularized xenografts in regenerative medicine: From processing to clinical application
Capella‐Monsonís, H., & Zeugolis, D. I. (2021) · Xenotransplantation · doi:10.1111/xen.12683 · Cited by 57
Duarte, M. M., Silva, I. V., Eisenhut, A. R., Bionda, N., Duarte, A. R. C., & Oliveira, A. L. (2022) · Materials Horizons · doi:10.1039/d1mh01720a · Cited by 45
Fast decellularization process using supercritical carbon dioxide for trabecular bone
Duarte, M. M., Ribeiro, N., Silva, I. V., Dias, J. R., Alves, N. M., & Oliveira, A. L. (2021) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2021.105194 · Cited by 22
Metadata
- Authors
- Sun, Y., Lovric, V., Wang, T., Oliver, R. A., & Walsh, W. R.
- Venue
- International Journal of Molecular Sciences
- Publisher
- MDPI AG
- Published
- 2020-02-25
- Volume
- 21
- Issue
- 5
- Pages
- 1565
- ISSN
- 1422-0067 (ISSN-L)
- OpenAlex
- W3007445065
- Cited by
- 27
- References
- 4
- FWCI
- 3.29
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.