Current and Future Use of Artificial Intelligence in Electrocardiography
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Artificial intelligence (AI) is increasingly used in electrocardiography (ECG) to assist in diagnosis, stratification, and management. AI algorithms can help clinicians in the following areas: (1) interpretation and detection of arrhythmias, ST-segment changes, QT prolongation, and other ECG abnormalities; (2) risk prediction integrated with or without clinical variables (to predict arrhythmias, sudden cardiac death, stroke, and other cardiovascular events); (3) monitoring ECG signals from cardiac implantable electronic devices and wearable devices in real time and alerting clinicians or patients when significant changes occur according to timing, duration, and situation; (4) signal processing, improving ECG quality and accuracy by removing noise/artifacts/interference, and extracting features not visible to the human eye (heart rate variability, beat-to-beat intervals, wavelet transforms, sample-level resolution, etc.); (5) therapy guidance, assisting in patient selection, optimizing treatments, improving symptom-to-treatment times, and cost effectiveness (earlier activation of code infarction in patients with ST-segment elevation, predicting the response to antiarrhythmic drugs or cardiac implantable devices therapies, reducing the risk of cardiac toxicity, etc.); (6) facilitating the integration of ECG data with other modalities (imaging, genomics, proteomics, biomarkers, etc.). In the future, AI is expected to play an increasingly important role in ECG diagnosis and management, as more data become available and more sophisticated algorithms are developed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Attia, Z. I., Noseworthy, P. A., Lopez-Jimenez, F., Asirvatham, S. J., Deshmukh, A. J., Gersh, B. J., Carter, R. E., Yao, X., Rabinstein, A. A., Erickson, B. J., et al. (2019) · The Lancet · doi:10.1016/s0140-6736(19)31721-0 · Cited by 1,613
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Automatic diagnosis of the 12-lead ECG using a deep neural network
Ribeiro, A. H., Ribeiro, M. H., Paixão, G. M. M., Oliveira, D. M., Gomes, P. R., Canazart, J. A., Ferreira, M. P. S., Andersson, C. R., Macfarlane, P. W., Meira, W., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-15432-4 · Cited by 894 · cited 1×
“[25] found that AI outperformed cardiology resident medical doctors in recognizing six types of abnormalities in 12-lead ECG recordings with F1 scores above 80% and specificity over 99%.”
BackgroundPassive Detection of Atrial Fibrillation Using a Commercially Available Smartwatch
Tison, G. H., Sanchez, J. M., Ballinger, B., Singh, A., Olgin, J. E., Pletcher, M. J., Vittinghoff, E., Lee, E. S., Fan, S. M., Gladstone, R. A., et al. (2018) · JAMA Cardiology · doi:10.1001/jamacardio.2018.0136 · Cited by 566
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498 · cited 1×
“The ZioPatch device us s an AI-powered algorithm to analyze continuous ECG recordi gs for up to 14 days and has b en shown to improve the detection of arrhythmias and other cardiac events compared to conventional Holter monitoring [77,78].”
MethodStehlik, J., Schmalfuss, C., Bozkurt, B., Nativi-Nicolau, J., Wohlfahrt, P., Wegerich, S., Rose, K., Ray, R., Schofield, R., Deswal, A., et al. (2020) · Circulation Heart Failure · doi:10.1161/circheartfailure.119.006513 · Cited by 333 · cited 1×
“AI provides accurate early detection of heart failure rehospitalization [71].”
BackgroundPrediction of mortality from 12-lead electrocardiogram voltage data using a deep neural network
Raghunath, S., Ulloa Cerna, A. E., Jing, L., vanMaanen, D. P., Stough, J., Hartzel, D. N., Leader, J. B., Kirchner, H. L., Stumpe, M. C., Hafez, A., et al. (2020) · Nature Medicine · doi:10.1038/s41591-020-0870-z · Cited by 314
Raghunath, S., Pfeifer, J. M., Ulloa-Cerna, A. E., Nemani, A., Carbonati, T., Jing, L., vanMaanen, D. P., Hartzel, D. N., Ruhl, J. A., Lagerman, B. F., et al. (2021) · Circulation · doi:10.1161/circulationaha.120.047829 · Cited by 312 · cited 2×
“For instance, ECG data from implantable devices can accurately predict electrical remodeling, forecasting the progression from paroxysmal to persistent atrial fibrillation [64], and a deep learning model can identify patients at high risk for new-onset atrial fibrillation [65].”
Background
Cited by
Foundation models for electrocardiogram interpretation: clinical implications
Nolin-Lapalme, A., Sowa, A., Delfrate, J., Tastet, O., Corbin, D., Kulbay, M., Ozdemir, D., Noël, M.-J., Marois-Blanchet, F.-C., Harvey, F., et al. (2026) · European Heart Journal · doi:10.1093/eurheartj/ehaf1119 · Cited by 20
Palantzas, A., & Anagnostouli, M. (2025) · International Journal of Molecular Sciences · doi:10.3390/ijms26178217 · Cited by 11
“AI ECG analysis detects AF, AV block, VT, silent AF [189–194], LV dysfunction, hypertrophic cardiomyopathy, valvular disease, amyloidosis (AUC 0.95–0.98), conduction, and ischemic abnormalities with near 100% sensitivity [192,195].”
InfluentialLi, Y., Gao, W., Luan, Z., Zhou, Z., & Li, J. (2023) · Cureus · doi:10.7759/cureus.48670 · Cited by 11
Metadata
- Authors
- Martínez-Sellés, M., & Marina-Breysse, M.
- Venue
- Journal of Cardiovascular Development and Disease
- Publisher
- MDPI AG
- Published
- 2023-04-17
- Volume
- 10
- Issue
- 4
- Pages
- 175
- ISSN
- 2308-3425 (ISSN-L)
- OpenAlex
- W4366281306
- Cited by
- 139
- References
- 18
- FWCI
- 24.45
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.